<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Stoney_Nakoda_Health_Centre</id>
	<title>Stoney Nakoda Health Centre - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Stoney_Nakoda_Health_Centre"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Stoney_Nakoda_Health_Centre&amp;action=history"/>
	<updated>2026-04-27T20:57:39Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Stoney_Nakoda_Health_Centre&amp;diff=12885&amp;oldid=prev</id>
		<title>TwentyThree33: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Notifier NFS-320C&lt;br /&gt;FACP Location: Main Entrance Vestibule&lt;br /&gt;System Type: Single-Stage Addressable&lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VDC&lt;br /&gt;System Coding: Temporal&lt;br&gt;Strobes Synchronized: Yes, System Sensor&lt;br /&gt;Date of last known Upgrade: 2023&lt;br /&gt;Most Recent Known Modification: N/A&lt;br /&gt;Year Opened: 1998, 2023 |}  &#039;&#039;&#039;Stoney Nakoda Health Centre&#039;&#039;&#039; is a...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Stoney_Nakoda_Health_Centre&amp;diff=12885&amp;oldid=prev"/>
		<updated>2025-06-17T03:51:51Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Notifier NFS-320C&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor&amp;lt;br /&amp;gt;Date of last known Upgrade: 2023&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1998, 2023 |}  &amp;#039;&amp;#039;&amp;#039;Stoney Nakoda Health Centre&amp;#039;&amp;#039;&amp;#039; is a...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Notifier NFS-320C&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor&amp;lt;br /&amp;gt;Date of last known Upgrade: 2023&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1998, 2023&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Stoney Nakoda Health Centre&amp;#039;&amp;#039;&amp;#039; is a health centre located on the Stoney Nakoda First Nation, in Mini Thni, Alberta, Canada.  The building was built in 1998, and was expanded and renovated in 2023.  The fire alarm system was upgraded as part of the 2023 expansion and renovation.&lt;br /&gt;
&lt;br /&gt;
==System Specifications (2023-present)==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Notifier NFS-320C addressable fire alarm system.  The panel is located in the main entrance vestibule.  The system runs Notifier&amp;#039;s FlashScan addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
=====Booster Panels=====&lt;br /&gt;
There is a Notifier ACPS-610 addressable booster power supply in the mechanical room.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances are System Sensor &amp;quot;L-Series&amp;quot; P2RLA horn/strobes (red, wall-mount, bilingual lettering, set to 15cd).  &amp;lt;br&amp;gt;There are System Sensor SRLA remote strobes (red, wall-mount, bilingual lettering, set to 15cd) in all washrooms.&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Notifier NBG-12LX addressable dual-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Notifier FSP-951A addressable photoelectric smoke detectors throughout all corridors, and in all electrical, data and server rooms.  &amp;lt;br&amp;gt;There are Notifier FST-951RA addressable 135°F fixed-temperature/rate-of-rise heat detectors in all storage rooms, all kitchens, some event rooms, and in the dental mechanical room.  There are two Notifier FST-951A addressable 135°F fixed-temperature heat detectors in the mechanical room.  &amp;lt;br&amp;gt;All detectors are mounted on System Sensor B300A-6 bases.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are Notifier FRM-1A addressable relay modules serving various purposes.  &amp;lt;br&amp;gt;There are Notifier ISO-XA isolator modules on the SLC.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Notifier EOL-CR end of line resistor plates on all signal circuits.&lt;br /&gt;
&lt;br /&gt;
==Former System Specifications (1998-2023)==&lt;br /&gt;
{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! Former System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Notifier SFP-400B &amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Continuous&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br/&amp;gt;Year Installed: 1998&amp;lt;br /&amp;gt;Year Decommissioned: 2023&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
====FACP====&lt;br /&gt;
The building was protected by a Notifier SFP-400B conventional fire alarm system.  The panel was located in the main entrance vestibule.  The system coding was continuous.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances were System Sensor &amp;quot;Multi-Alert&amp;quot; MASS24LOA sounder/strobes (red, wall-mount, 1.5cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
Most pull stations were Notifier NFM-950B conventional single-action pull stations.  &amp;lt;br&amp;gt;Some areas had Simplex MS-301C conventional single-action pull stations as deficiency replacements.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There were FDD CR-135 conventional 135°F fixed-temperature/rate-of-rise heat detectors in most rooms.  &amp;lt;br&amp;gt;There were FDD CF-200 conventional 200°F fixed-temperature heat detectors in the mechanical room.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There were Notifier EOL-CR end of line resistor plates on all circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Alberta]]&lt;br /&gt;
[[Category:Healthcare]]&lt;/div&gt;</summary>