		<id>https://firealarmpedia.org/index.php?title=Sundance_Mall&amp;diff=12640&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Notifier NFS-320C &lt;br /&gt;FACP Location: Unknown &lt;br /&gt;System Type: Single-Stage Addressable &lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VDC &lt;br /&gt;System Coding: Temporal &lt;br&gt;Strobes Synchronized: Yes, System Sensor &lt;br /&gt;Date of last known Upgrade: 2020 &lt;br /&gt;Most Recent Known Modification: N/A &lt;br /&gt; Year Opened: 1978 |}  &#039;&#039;&#039;Sundance Mall&#039;&#039;&#039; is a small mall located at 215...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Sundance_Mall&amp;diff=12640&amp;oldid=prev"/>
		<updated>2025-04-29T03:38:36Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Notifier NFS-320C &amp;lt;br /&amp;gt;FACP Location: Unknown &amp;lt;br /&amp;gt;System Type: Single-Stage Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor &amp;lt;br /&amp;gt;Date of last known Upgrade: 2020 &amp;lt;br /&amp;gt;Most Recent Known Modification: N/A &amp;lt;br /&amp;gt; Year Opened: 1978 |}  &amp;#039;&amp;#039;&amp;#039;Sundance Mall&amp;#039;&amp;#039;&amp;#039; is a small mall located at 215...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Notifier NFS-320C &amp;lt;br /&amp;gt;FACP Location: Unknown &amp;lt;br /&amp;gt;System Type: Single-Stage Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor &amp;lt;br /&amp;gt;Date of last known Upgrade: 2020 &amp;lt;br /&amp;gt;Most Recent Known Modification: N/A &amp;lt;br /&amp;gt; Year Opened: 1978&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Sundance Mall&amp;#039;&amp;#039;&amp;#039; is a small mall located at 215 Banff Ave, Banff, Alberta, Canada. The mall opened in 1978, and the fire alarm system was upgraded in 2020.&lt;br /&gt;
&lt;br /&gt;
== System Specifications (2020-present) ==&lt;br /&gt;
&lt;br /&gt;
==== FACP ====&lt;br /&gt;
&lt;br /&gt;
The building is protected by a Notifier NFS-320C addressable fire alarm system. The panel location is unknown. The system runs Notifier&amp;#039;s FlashScan addressable protocol, and the system coding is temporal. &lt;br /&gt;
&lt;br /&gt;
===== Annunciators =====&lt;br /&gt;
&lt;br /&gt;
There is a Notifier LCD2-80 annunciator paired with a Notifier ACM-24AT annunciator in the main entrance vestibule.&lt;br /&gt;
&lt;br /&gt;
==== Notification Appliances ====&lt;br /&gt;
&lt;br /&gt;
All notification appliances are System Sensor &amp;quot;L-Series&amp;quot; P2RLA horn/strobes (red, wall-mount, set to 15cd). &lt;br /&gt;
&lt;br /&gt;
=== Initiating Devices ===&lt;br /&gt;
&lt;br /&gt;
==== Pull Stations ====&lt;br /&gt;
&lt;br /&gt;
All pull stations are Notifier NBG-12LX addressable dual-action pull stations.&lt;br /&gt;
&lt;br /&gt;
==== Automatic Detection Devices ====&lt;br /&gt;
&lt;br /&gt;
There are Notifier FSP-951A addressable photoelectric smoke detectors in the stairwells. &amp;lt;br&amp;gt; There are Notifier FST-951A addressable 135°F fixed-temperature heat detectors in the electrical rooms. &amp;lt;br&amp;gt; All detectors are mounted on System Sensor B300A-6 bases.&lt;br /&gt;
&lt;br /&gt;
==== EOLs ====&lt;br /&gt;
&lt;br /&gt;
There are Notifier EOL-CR end-of-line resistor plates on all signal circuits.&lt;br /&gt;
&lt;br /&gt;
== Former System Specifications (1978-2020) ==&lt;br /&gt;
&lt;br /&gt;
{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! Former System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Edwards 2280 &amp;lt;br /&amp;gt;FACP Location: Unknown &amp;lt;br /&amp;gt;System Type: Single-Stage Conventional &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;System Coding: Continuous &amp;lt;br /&amp;gt;Date of last known Upgrade: N/A &amp;lt;br /&amp;gt; Most Recent Known Modification: 1990s &amp;lt;br/&amp;gt; Year Installed: 1978 &amp;lt;br /&amp;gt;Year Decommissioned: 2020&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
==== FACP ====&lt;br /&gt;
&lt;br /&gt;
The building was protected by an Edwards 2280 conventional fire alarm system. The panel location was unknown. The system coding was continuous.&lt;br /&gt;
&lt;br /&gt;
===== Annunciators =====&lt;br /&gt;
&lt;br /&gt;
There was an Edwards annunciator at the entrance, model unknown.&lt;br /&gt;
&lt;br /&gt;
==== Notification Appliances ====&lt;br /&gt;
&lt;br /&gt;
All notification appliances but one were Edwards &amp;quot;Durabel&amp;quot; 6100D vibrating bells (6&amp;quot; gong). &amp;lt;br&amp;gt; There was an Edwards 439D-6AWC vibrating bell as a deficiency replacement.&lt;br /&gt;
&lt;br /&gt;
=== Initiating Devices ===&lt;br /&gt;
&lt;br /&gt;
==== Pull Stations ====&lt;br /&gt;
&lt;br /&gt;
All pull stations were Edwards 270-SPO conventional single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
==== Automatic Detection Devices ====&lt;br /&gt;
&lt;br /&gt;
There were Edwards 281A conventional 135°F fixed-temperature/rate-of-rise heat detectors at the top of each stairwell and in the electrical rooms. &lt;br /&gt;
&lt;br /&gt;
[[Category:Alberta]]&lt;br /&gt;
[[Category:Strip Malls]]&lt;/div&gt;</summary>