		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Fire-Lite MS-9200UDLS&lt;br /&gt;FACP Location: Main Electrical Room?&lt;br /&gt;System Type: Single-Stage Conventional&lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VDC&lt;br /&gt;System Coding: Temporal?&lt;br&gt;Strobes Synchronized: N/A&lt;br /&gt;Date of last known Upgrade: N/A&lt;br /&gt;Most Recent Known Modification: 2010s, FACP&lt;br /&gt;Year Opened: 1977 |}  &#039;&#039;&#039;The Mall At Piccadilly&#039;&#039;&#039; is a shopping mall...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=The_Mall_at_Piccadilly&amp;diff=13452&amp;oldid=prev"/>
		<updated>2025-12-19T04:49:17Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Fire-Lite MS-9200UDLS&amp;lt;br /&amp;gt;FACP Location: Main Electrical Room?&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal?&amp;lt;br&amp;gt;Strobes Synchronized: N/A&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: 2010s, FACP&amp;lt;br /&amp;gt;Year Opened: 1977 |}  &amp;#039;&amp;#039;&amp;#039;The Mall At Piccadilly&amp;#039;&amp;#039;&amp;#039; is a shopping mall...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Fire-Lite MS-9200UDLS&amp;lt;br /&amp;gt;FACP Location: Main Electrical Room?&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal?&amp;lt;br&amp;gt;Strobes Synchronized: N/A&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: 2010s, FACP&amp;lt;br /&amp;gt;Year Opened: 1977&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;The Mall At Piccadilly&amp;#039;&amp;#039;&amp;#039; is a shopping mall located at 1151 10 Ave SW, in Salmon Arm, British Columbia, Canada.  The mall was built in 1977, and the fire alarm system is mostly original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
Please note that some information may be missing, as research time was limited for this facility.  This page should not be used for official purposes.&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Fire-LIte MS-9200UDLSC conventional fire alarm system.  The panel is likely located in the main electrical room.  The system is equipped with several Fire-Lite MMF-302-6 zone cards, and the system coding is likely temporal.  &amp;lt;br&amp;gt;This panel replaced an Edwards Custom 6500 in the 2010s.&lt;br /&gt;
&lt;br /&gt;
=====Annunciators=====&lt;br /&gt;
There are two Fire-Lite ANN-LED annunciators in the main entrance vestibule.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are Edwards &amp;quot;Durabel&amp;quot; 6100D vibrating bells (10&amp;quot; gong).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Edwards 270-SPO conventional single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
None noticed.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Edwards EOL-P1 end of line resistor plates on all circuits.&lt;br /&gt;