		<id>https://firealarmpedia.org/index.php?title=The_Rotunda&amp;diff=13431&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Simplex 4100ES&lt;br /&gt;FACP Location: Behind Security Desk&lt;br /&gt;System Type: Single-Stage Addressable&lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 70VRMS&lt;br /&gt;System Coding: Temporal &lt;br /&gt;Date of last known Upgrade: N/A&lt;br /&gt;Most Recent Known Modification: N/A&lt;br /&gt;Year Opened: 2018 |}  &#039;&#039;&#039;The Rotunda&#039;&#039;&#039; is a six-storey office and retail complex located at 1515 Douglas St, Victo...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=The_Rotunda&amp;diff=13431&amp;oldid=prev"/>
		<updated>2025-12-15T05:12:51Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Simplex 4100ES&amp;lt;br /&amp;gt;FACP Location: Behind Security Desk&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 70VRMS&amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2018 |}  &amp;#039;&amp;#039;&amp;#039;The Rotunda&amp;#039;&amp;#039;&amp;#039; is a six-storey office and retail complex located at 1515 Douglas St, Victo...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Simplex 4100ES&amp;lt;br /&amp;gt;FACP Location: Behind Security Desk&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 70VRMS&amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2018&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;The Rotunda&amp;#039;&amp;#039;&amp;#039; is a six-storey office and retail complex located at 1515 Douglas St, Victoria, British Columbia, Canada. The complex was completed in 2018, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
== System Specifications ==&lt;br /&gt;
&lt;br /&gt;
==== FACP ====&lt;br /&gt;
&lt;br /&gt;
The building is protected by a Simplex 4100ES addressable fire alarm system. The panel is located behind the security desk. The system runs Simplex&amp;#039;s IDNet addressable protocol, and is equipped with voice-evacuation. The system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
===== Annunciators =====&lt;br /&gt;
&lt;br /&gt;
There is a Simplex 4100 Operator Interface (FUI) at each entrance vestibule.&lt;br /&gt;
&lt;br /&gt;
==== Notification Appliances ====&lt;br /&gt;
&lt;br /&gt;
All notification appliances are Simplex 2902-9313 speakers (4&amp;quot;, square, 70V, ceiling-mount).&lt;br /&gt;
&lt;br /&gt;
=== Initiating Devices ===&lt;br /&gt;
&lt;br /&gt;
==== Pull Stations ====&lt;br /&gt;
&lt;br /&gt;
All pull stations are Simplex 4099-9004 addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
==== Automatic Detection Devices ====&lt;br /&gt;
&lt;br /&gt;
There are Simplex &amp;quot;TrueAlarm&amp;quot; 4098-9714 addressable photoelectric smoke detectors in some areas, mounted on Simplex 4098-9792 bases. &amp;lt;br&amp;gt; Each air handling unit has a Simplex 4098-9755 addressable photoelectric duct smoke detector.&lt;br /&gt;
&lt;br /&gt;
==== Modules ====&lt;br /&gt;
&lt;br /&gt;
There are Simplex 4090-9001 addressable monitor modules supervising the generator, and sprinkler system&amp;#039;s tamper and flow switches. &amp;lt;br&amp;gt; There are Simplex 4090-9002 addressable relay modules serving various purposes. &amp;lt;br&amp;gt; There are Simplex 4090-9116 addressable isolator modules on the SLC.&lt;br /&gt;
&lt;br /&gt;
==== EOLs ====&lt;br /&gt;
&lt;br /&gt;
There are Simplex 2081-9040C end-of-line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:British Columbia]]&lt;br /&gt;
[[Category:Office Buildings]]&lt;br /&gt;
[[Category:Simplex]]&lt;/div&gt;</summary>