	<entry>
		<id>https://firealarmpedia.org/index.php?title=True_North_Automation&amp;diff=13585&amp;oldid=prev</id>
		<title>TwentyThree33: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Simplex 4010&lt;br /&gt;FACP Location: Main Floor Elevator Lobby&lt;br /&gt;System Type: Single-Stage Conventional&lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VDC&lt;br /&gt;System Coding: Temporal?&lt;br&gt;Strobes Synchronized: N/A&lt;br /&gt;Date of last known Upgrade: 2000s&lt;br /&gt;Most Recent Known Modification: N/A&lt;br /&gt;Year Opened: 1982 |}  &#039;&#039;&#039;True North Automation&#039;&#039;&#039; is an automation company locate...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=True_North_Automation&amp;diff=13585&amp;oldid=prev"/>
		<updated>2026-03-06T21:29:56Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Simplex 4010&amp;lt;br /&amp;gt;FACP Location: Main Floor Elevator Lobby&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal?&amp;lt;br&amp;gt;Strobes Synchronized: N/A&amp;lt;br /&amp;gt;Date of last known Upgrade: 2000s&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1982 |}  &amp;#039;&amp;#039;&amp;#039;True North Automation&amp;#039;&amp;#039;&amp;#039; is an automation company locate...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Simplex 4010&amp;lt;br /&amp;gt;FACP Location: Main Floor Elevator Lobby&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal?&amp;lt;br&amp;gt;Strobes Synchronized: N/A&amp;lt;br /&amp;gt;Date of last known Upgrade: 2000s&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1982&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;True North Automation&amp;#039;&amp;#039;&amp;#039; is an automation company located at 7180 11 St SE, in Calgary, Alberta, Canada.  The building was built in 1982, and the fire alarm system is mostly original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Simplex 4010 conventional fire alarm system.  The panel is located in the main floor elevator lobby.  The system coding is likely temporal.  &amp;lt;br&amp;gt;This panel replaced a Pyrotronics System 3.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances are Pyr-A-Larm BDC-624C vibrating bells (6&amp;quot; gong).  &amp;lt;br&amp;gt;Some areas have Mircom BL-6B motor bells (6&amp;quot; gong), and other areas have Edwards &amp;quot;Durabel&amp;quot; 6100D vibrating bells (6&amp;quot; gong).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
Most pull stations are Pyrotronics MS-51 conventional single-action pull stations.  &amp;lt;br&amp;gt;Some areas have Mircom MS-401 conventional single-action pull stations as deficiency replacements.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Mirtone 73330 conventional 135°F fixed-temperature heat detectors in some rooms.  &amp;lt;br&amp;gt;There are Potter CR-135W conventional 135°F fixed-temperature/rate-of-rise heat detectors in all kitchens.  &amp;lt;br&amp;gt;There are Edwards C2M-PD conventional photoelectric smoke detectors at the top of each stairwell, and in one automation lab.  &amp;lt;br&amp;gt;There are System Sensor 1400A conventional ionization smoke detectors in all server rooms and in one automation lab.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Simplex 2081-9040C end of line resistor plates on all circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Industrial]]&lt;br /&gt;
[[Category:Simplex]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>