	<entry>
		<id>https://firealarmpedia.org/index.php?title=University_at_Albany_School_of_Business&amp;diff=9412&amp;oldid=prev</id>
		<title>Alberta Fire Alarms at 06:00, 28 May 2024</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=University_at_Albany_School_of_Business&amp;diff=9412&amp;oldid=prev"/>
		<updated>2024-05-28T06:00:57Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 00:00, 28 May 2024&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l23&quot;&gt;Line 23:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 23:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;====Automatic Detection Devices====&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;====Automatic Detection Devices====&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;There are Simplex 4098-9714 addressable photoelectric smoke detectors throughout the building, mounted on 4098-9792 bases. In open-ceiling areas, there are System Sensor BEAM1224 4-wire conventional projected beam smoke detectors, wired to Simplex 4090-9001 addressable modules.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;There are Simplex 4098-9714 addressable photoelectric smoke detectors throughout the building, mounted on 4098-9792 bases. In open-ceiling areas, there are System Sensor BEAM1224 4-wire conventional projected beam smoke detectors, wired to Simplex 4090-9001 addressable modules.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[Category:New York]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[Category:Post-Secondary]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Alberta Fire Alarms</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=University_at_Albany_School_of_Business&amp;diff=6749&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: the last UAlbany page! Credits to weatherdan882002.</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=University_at_Albany_School_of_Business&amp;diff=6749&amp;oldid=prev"/>
		<updated>2024-01-02T18:44:19Z</updated>

		<summary type="html">&lt;p&gt;the last UAlbany page! Credits to weatherdan882002.&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!System Specifications&lt;br /&gt;
|-&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|FACP: Simplex 4100ES&amp;lt;br /&amp;gt;FACP Location: Fire Command Center&amp;lt;br /&amp;gt;System Type: Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 70VRMS (audible)&lt;br /&gt;
24VDC (Visual)&amp;lt;br /&amp;gt;System Coding: Unknown&amp;lt;br&amp;gt;Strobes Synchronized: Yes, SmartSync&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Year Opened: 2013&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
The University at Albany is a public research university with campuses in Albany, Rensselaer and Guilderland, NY. It was founded in 1844, is part of the State University of New York system, and enrolls over 17,900 students. The Uptown Campus in Albany is most known for being in weatherdan882002’s UAlbany fire alarm and fire drill videos. This page will cover the School of Business, which replaced the Business Administration building/Catskill building. The building was built in 2013 and has the original fire alarm system. &lt;br /&gt;
==System Specifications (2013-present)==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Simplex 4100ES addressable fire alarm system. The panel is most likely in the Fire Command Center which is near the entrance, and was installed during construction. The system runs Simplex’s IDNet addressable protocol, and is equipped with voice-evacuation. The tones are unknown, but are most likely slow whoop with the default message. &lt;br /&gt;
=====Annunciators=====&lt;br /&gt;
There is a Simplex 4100ES Remote Command Center at the south entrance. It consists of a Simplex 4100-1292 panel-mounted LCD annunciator unit, a 4100-1244 microphone, and two 4100-1255 8-channel switches, in a 2-bay cabinet.&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All of the notification appliances are from Simplex’s “TrueAlert” line of products. Throughout the building, there are Simplex 4906-9151 (red, wall-mount, multi-candela) speaker/strobes, also installed in the restrooms. In the lobby and other large areas where more sound coverage is required, there are Simplex 4902-9716 (red, wall-mount) speakers. In the classrooms, group study areas and other places where more visual coverage is needed, there are Simplex 4906-9101 (red, wall-mount, multi-candela) remote strobes.&lt;br /&gt;
===Initating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Simplex 4099-9003 addressable dual-action pull stations.&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Simplex 4098-9714 addressable photoelectric smoke detectors throughout the building, mounted on 4098-9792 bases. In open-ceiling areas, there are System Sensor BEAM1224 4-wire conventional projected beam smoke detectors, wired to Simplex 4090-9001 addressable modules.&lt;/div&gt;</summary>