<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Vista_Pointe_B</id>
	<title>Vista Pointe B - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Vista_Pointe_B"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Vista_Pointe_B&amp;action=history"/>
	<updated>2026-04-27T19:24:43Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Vista_Pointe_B&amp;diff=12067&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Alberta Fire Alarms moved page Vista Pointe 408 to Vista Pointe B without leaving a redirect</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Vista_Pointe_B&amp;diff=12067&amp;oldid=prev"/>
		<updated>2025-01-18T04:14:59Z</updated>

		<summary type="html">&lt;p&gt;Alberta Fire Alarms moved page &lt;a href=&quot;/index.php?title=Vista_Pointe_408&amp;amp;action=edit&amp;amp;redlink=1&quot; class=&quot;new&quot; title=&quot;Vista Pointe 408 (page does not exist)&quot;&gt;Vista Pointe 408&lt;/a&gt; to &lt;a href=&quot;/index.php/Vista_Pointe_B&quot; title=&quot;Vista Pointe B&quot;&gt;Vista Pointe B&lt;/a&gt; without leaving a redirect&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;1&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;1&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 22:14, 17 January 2025&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-notice&quot; lang=&quot;en&quot;&gt;&lt;div class=&quot;mw-diff-empty&quot;&gt;(No difference)&lt;/div&gt;
&lt;/td&gt;&lt;/tr&gt;&lt;/table&gt;</summary>
		<author><name>Alberta Fire Alarms</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Vista_Pointe_B&amp;diff=11916&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Mircom FX-2000 &lt;br /&gt;FACP Location: Main Entrance Vestibule &lt;br /&gt;System Type: Single-Stage Addressable &lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VFWR &lt;br /&gt;System Coding: Temporal &lt;br&gt;Strobes Synchronized: Yes, Mircom &lt;br /&gt;Date of last known Upgrade: N/A &lt;br /&gt;Year Opened: 2013 |}  &#039;&#039;&#039;Vista Pointe&#039;&#039;&#039; is an apartment complex owned by Broadstreet.  This page will cover B...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Vista_Pointe_B&amp;diff=11916&amp;oldid=prev"/>
		<updated>2024-12-29T07:39:09Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Mircom FX-2000 &amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule &amp;lt;br /&amp;gt;System Type: Single-Stage Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: Yes, Mircom &amp;lt;br /&amp;gt;Date of last known Upgrade: N/A &amp;lt;br /&amp;gt;Year Opened: 2013 |}  &amp;#039;&amp;#039;&amp;#039;Vista Pointe&amp;#039;&amp;#039;&amp;#039; is an apartment complex owned by Broadstreet.  This page will cover B...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Mircom FX-2000 &amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule &amp;lt;br /&amp;gt;System Type: Single-Stage Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: Yes, Mircom &amp;lt;br /&amp;gt;Date of last known Upgrade: N/A &amp;lt;br /&amp;gt;Year Opened: 2013&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Vista Pointe&amp;#039;&amp;#039;&amp;#039; is an apartment complex owned by Broadstreet.  This page will cover Building 408, located at 408 McConachie Way NW, in Edmonton, Alberta, Canada.  The building was built in 2013, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
== System Specifications (2013-present) ==&lt;br /&gt;
&lt;br /&gt;
==== FACP ====&lt;br /&gt;
&lt;br /&gt;
The building is protected by a Mircom FX-2000 addressable fire alarm system.  The panel is located in the main entrance vestibule.  The system runs Mircom’s CLIP addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
==== Notification Appliances ====&lt;br /&gt;
&lt;br /&gt;
Most common area notification appliances are Mircom “Select-a-Horn/Strobe” FHS-340R horn/strobes (red, wall-mount, set to 15cd/electromechanical). &amp;lt;br&amp;gt; There is a Mircom FHS-400-RR horn/strobes (red, wall-mount, set to 15cd) on the 2nd and 4th floor each as deficiency replacements. &amp;lt;br&amp;gt; All suite bedrooms have Mircom MH-S25WA silenceable mini-horns (white).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Mircom MS-401AD addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Mircom MIX-2251BA addressable photoelectric smoke detectors throughout all common areas.  &amp;lt;br&amp;gt; There is a Mircom MIX-2251APA addressable photoelectric smoke detector in the lobby as a deficiency replacement. &amp;lt;br&amp;gt; There are Mircom MIX-5251HBA addressable 190°F fixed-temperature/rate-of-rise heat detectors in the mechanical room.  &amp;lt;br&amp;gt;All aforementioned detectors are mounted on System Sensor B210LPA bases.  &amp;lt;br&amp;gt;There are System Sensor DNRA duct smoke detector housings with Mircom MIX-2251BA addressable photoelectric head on all make up air units.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are Mircom MIX-M500MA addressable monitor modules supervising the sprinkler system’s tamper and flow switches.  &amp;lt;br&amp;gt;There are Mircom MIX-M500RA addressable relay modules for elevator recall and MUA shutdown.  &amp;lt;br&amp;gt;There are System Sensor M500XA isolator modules at each stairwell on each floor.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Mircom MP-300 end of line resistor plates on all sprinkler and Class-B signal circuits.&lt;br /&gt;