<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Walmart_Supercentre_%28Bedford_Commons%29</id>
	<title>Walmart Supercentre (Bedford Commons) - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Walmart_Supercentre_%28Bedford_Commons%29"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Walmart_Supercentre_(Bedford_Commons)&amp;action=history"/>
	<updated>2026-09-04T10:12:14Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Walmart_Supercentre_(Bedford_Commons)&amp;diff=13883&amp;oldid=prev</id>
		<title>TwentyThree33: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: EST QuickStart QS1&lt;br /&gt;FACP Location: Main Entrance Vestibule&lt;br /&gt;System Type: Single-Stage Addressable&lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VFWR (FACP)&lt;br&gt;24VDC (Booster)&lt;br /&gt;System Coding: Temporal&lt;br&gt;Strobes Synchronized: Yes, Self-Sync&lt;br /&gt;Date of last known Upgrade: N/A&lt;br /&gt;Most Recent Known Modification: N/A&lt;br /&gt;Year Opened: 2007 |}  &#039;&#039;&#039;Walmart Supercentr...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Walmart_Supercentre_(Bedford_Commons)&amp;diff=13883&amp;oldid=prev"/>
		<updated>2026-09-03T23:42:05Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: EST QuickStart QS1&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR (FACP)&amp;lt;br&amp;gt;24VDC (Booster)&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Self-Sync&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2007 |}  &amp;#039;&amp;#039;&amp;#039;Walmart Supercentr...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: EST QuickStart QS1&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR (FACP)&amp;lt;br&amp;gt;24VDC (Booster)&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Self-Sync&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2007&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Walmart Supercentre&amp;#039;&amp;#039;&amp;#039; is a chain of hypermarkets headquartered in Bentonville, Arkansas, USA.  This particular store is located at 141 Damascus Road, in Bedford, Nova Scotia, Canada.  The building was built in 2007, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an EST QuickStart QS1 addressable fire alarm system.  The panel is located in the main entrance vestibule.  The system runs EST&amp;#039;s Signature addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
=====Booster Panels=====&lt;br /&gt;
There are Edwards BPS6AC 6-amp booster power supplies on the system.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances are a mix of Edwards &amp;quot;Genesis&amp;quot; G1R-HDVM and G1-HDVM horn/strobes (red/white, wall-mount, no marking, set to 15cd).  &amp;lt;br&amp;gt;There are Edwards G1R-VM and G1-VM remote strobes (red/white, wall-mount, no marking, set to 15cd) throughout the storefront and in other areas requiring additional visual coverage.&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are EST SIGC-270B addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
None noticed.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are EST SIGA-CT1 addressable monitor modules supervising the kitchen suppression systems, and the sprinkler system&amp;#039;s tamper and flow switches.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Edwards EOL-P1 end of line resistor plates on all kitchen suppression, sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
==Credits==&lt;br /&gt;
Thank you to NSS for submitting this system!&lt;br /&gt;
&lt;br /&gt;
[[Category:Nova Scotia]]&lt;br /&gt;
[[Category:Walmart]]&lt;br /&gt;
[[Category:Retail Stores]]&lt;br /&gt;
[[Category:Edwards]]&lt;/div&gt;</summary>