		<id>https://firealarmpedia.org/index.php?title=Westlink_Park&amp;diff=13523&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Notifier NFS-320C&lt;br /&gt;FACP Location: Main Entrance Vestiuble&lt;br /&gt;System Type: Single-Stage Addressable&lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VDC&lt;br /&gt;System Coding: Temporal&lt;br&gt;Strobes Synchronized: Yes, System Sensor &lt;br /&gt;Date of last known Upgrade: N/A &lt;br /&gt;Most Recent Known Modification: N/A &lt;br /&gt;Year Opened: 2014 |}  &#039;&#039;&#039;Westlink Park&#039;&#039;&#039; is an office building...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Westlink_Park&amp;diff=13523&amp;oldid=prev"/>
		<updated>2026-02-15T06:46:11Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Notifier NFS-320C&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestiuble&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor &amp;lt;br /&amp;gt;Date of last known Upgrade: N/A &amp;lt;br /&amp;gt;Most Recent Known Modification: N/A &amp;lt;br /&amp;gt;Year Opened: 2014 |}  &amp;#039;&amp;#039;&amp;#039;Westlink Park&amp;#039;&amp;#039;&amp;#039; is an office building...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Notifier NFS-320C&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestiuble&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor &amp;lt;br /&amp;gt;Date of last known Upgrade: N/A &amp;lt;br /&amp;gt;Most Recent Known Modification: N/A &amp;lt;br /&amp;gt;Year Opened: 2014&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Westlink Park&amp;#039;&amp;#039;&amp;#039; is an office building located at 16826 107 Ave NW, Edmonton, Alberta. The building was completed in 2014, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
== System Specifications ==&lt;br /&gt;
&lt;br /&gt;
==== FACP ====&lt;br /&gt;
&lt;br /&gt;
The building is protected by a Notifier NFS-320C addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Notifier&amp;#039;s FlashScan addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
==== Notification Appliances ====&lt;br /&gt;
&lt;br /&gt;
All indoor notification appliances are System Sensor &amp;quot;SpectrAlert Advance&amp;quot; P2RA horn/strobes (red, wall-mount, set to 15cd). &amp;lt;br&amp;gt; For exterior notification, there is a System Sensor P2RKA weatherproof horn/strobe (red, wall-mount, set to 75cd) outside the main entrance.&lt;br /&gt;
&lt;br /&gt;
=== Initiating Devices ===&lt;br /&gt;
&lt;br /&gt;
==== Pull Stations ====&lt;br /&gt;
&lt;br /&gt;
All pull stations are Notifier NBG-12LX addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
==== Automatic Detection Devices ====&lt;br /&gt;
&lt;br /&gt;
There are Notifier FSP-851A addressable photoelectric smoke detectors throughout the building. &amp;lt;br&amp;gt; Some rooms have Notifier FST-851A addressable 135°F fixed-temperature heat detectors. &amp;lt;br&amp;gt; All detectors are mounted on System Sensor B210LPA bases.&lt;br /&gt;
&lt;br /&gt;
==== Modules ====&lt;br /&gt;
&lt;br /&gt;
There are Notifier FDM-1A addressable dual-input monitor modules supervising the sprinkler system&amp;#039;s tamper and flow switches. &amp;lt;br&amp;gt; There are Notifier FRM-1A addressable relay modules serving various purposes. &amp;lt;br&amp;gt; There are Notifier ISO-XA isolator modules on the SLC.&lt;br /&gt;
&lt;br /&gt;
==== EOLs ====&lt;br /&gt;
&lt;br /&gt;
There are Notifier EOL-CR end-of-line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;