		<id>https://firealarmpedia.org/index.php?title=Westshore_Town_Centre&amp;diff=13450&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Edwards EST3&lt;br /&gt;FACP Location: Security Office&lt;br /&gt;System Type: Two-Stage Addressable&lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VDC&lt;br /&gt;System Coding: 20BPM (Alert)&lt;br&gt;Temporal (Alarm)&lt;br&gt;Strobes Synchronized: Yes, EST&lt;br /&gt;Date of last known Upgrade: 2010&lt;br /&gt;Most Recent Known Modification: N/A&lt;br /&gt;Year Opened: 1984 |}  &#039;&#039;&#039;Westshore Town Centre&#039;&#039;&#039; is a shopping mal...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Westshore_Town_Centre&amp;diff=13450&amp;oldid=prev"/>
		<updated>2025-12-19T04:48:45Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Edwards EST3&amp;lt;br /&amp;gt;FACP Location: Security Office&amp;lt;br /&amp;gt;System Type: Two-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: 20BPM (Alert)&amp;lt;br&amp;gt;Temporal (Alarm)&amp;lt;br&amp;gt;Strobes Synchronized: Yes, EST&amp;lt;br /&amp;gt;Date of last known Upgrade: 2010&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1984 |}  &amp;#039;&amp;#039;&amp;#039;Westshore Town Centre&amp;#039;&amp;#039;&amp;#039; is a shopping mal...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Edwards EST3&amp;lt;br /&amp;gt;FACP Location: Security Office&amp;lt;br /&amp;gt;System Type: Two-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: 20BPM (Alert)&amp;lt;br&amp;gt;Temporal (Alarm)&amp;lt;br&amp;gt;Strobes Synchronized: Yes, EST&amp;lt;br /&amp;gt;Date of last known Upgrade: 2010&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1984&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Westshore Town Centre&amp;#039;&amp;#039;&amp;#039; is a shopping mall located at 2945 Jacklin Road, in Langford, British Columbia, Canada.  The mall was built in 1984, and the fire alarm system was upgraded in 2010.&lt;br /&gt;
&lt;br /&gt;
==System Specifications (2010-present)==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an Edwards EST3 addressable fire alarm system.  The panel is located in the security office.  The system runs Edwards&amp;#039; Signature addressable protocol, and is configured for two-stage operation.  The alert signal coding is 20BPM, and the alarm signal coding is temporal.&lt;br /&gt;
&lt;br /&gt;
=====Annunciators=====&lt;br /&gt;
There is an Edwards EST3-6ANN annunciator at the northwest entrance, equipped with an LCDXL1 display.&lt;br /&gt;
&lt;br /&gt;
=====Booster Panels=====&lt;br /&gt;
There are likely Edwards BPS6A 6-amp booster power supplies on the system.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances are Edwards 439D-10AWC vibrating bells (10&amp;quot; gong), mounted remotely in the main mall, and mounted on Edwards 403-5A-R strobe plates (15cd) in Winners and other areas.  &amp;lt;br&amp;gt;Some areas of the main mall have Edwards &amp;quot;Durabel&amp;quot; 6100D vibrating bells (10&amp;quot; gong), remaining from the original system.&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are EST SIGA-270P addressable two-stage single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are EST SIGA-PS addressable photoelectric smoke detectors in some areas.  &amp;lt;br&amp;gt;There are EST SIGA-HRS addressable 135°F fixed-temperature/rate-of-rise heat detectors in some areas.  &amp;lt;br&amp;gt;All aforementioned detectors are mounted on EST SIGA-SB bases.  &amp;lt;br&amp;gt;There are EST &amp;quot;SuperDuct&amp;quot; SIGA-SD addressable photoelectric duct smoke detectors on all air handling units.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are EST SIGA-CT1 addressable monitor modules supervising all kitchen suppression systems, and the sprinkler system&amp;#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are EST SIGA-CR addressable relay modules serving various purposes.  &amp;lt;br&amp;gt;There are EST SIGA-CC1 addressable control modules triggering all booster panels.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Edwards EOL-P1 end of line resistor plates on all kitchen suppression, sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Shopping Malls]]&lt;br /&gt;
[[Category:British Columbia]]&lt;br /&gt;
[[Category:Edwards]]&lt;/div&gt;</summary>