<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Willow_Lodge_J2</id>
	<title>Willow Lodge J2 - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Willow_Lodge_J2"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Willow_Lodge_J2&amp;action=history"/>
	<updated>2026-04-28T00:18:13Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Willow_Lodge_J2&amp;diff=12732&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Mircom FA-1000 &lt;br /&gt;FACP Location: Centre Hallway Exit &lt;br /&gt;System Type: Single-Stage Conventional &lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VFWR &lt;br /&gt;System Coding: Temporal &lt;br&gt;Strobes Synchronized: Yes, Mircom &lt;br /&gt;Date of last known Upgrade: N/A &lt;br /&gt;Most Recent Known Modification: 2023, FACP&lt;br /&gt; Year Opened: 2014 |}  &#039;&#039;&#039;Willow Lodge&#039;&#039;&#039; is a Suncor camp locate...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Willow_Lodge_J2&amp;diff=12732&amp;oldid=prev"/>
		<updated>2025-05-13T04:20:28Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Mircom FA-1000 &amp;lt;br /&amp;gt;FACP Location: Centre Hallway Exit &amp;lt;br /&amp;gt;System Type: Single-Stage Conventional &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: Yes, Mircom &amp;lt;br /&amp;gt;Date of last known Upgrade: N/A &amp;lt;br /&amp;gt;Most Recent Known Modification: 2023, FACP&amp;lt;br /&amp;gt; Year Opened: 2014 |}  &amp;#039;&amp;#039;&amp;#039;Willow Lodge&amp;#039;&amp;#039;&amp;#039; is a Suncor camp locate...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Mircom FA-1000 &amp;lt;br /&amp;gt;FACP Location: Centre Hallway Exit &amp;lt;br /&amp;gt;System Type: Single-Stage Conventional &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: Yes, Mircom &amp;lt;br /&amp;gt;Date of last known Upgrade: N/A &amp;lt;br /&amp;gt;Most Recent Known Modification: 2023, FACP&amp;lt;br /&amp;gt; Year Opened: 2014&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Willow Lodge&amp;#039;&amp;#039;&amp;#039; is a Suncor camp located in Wood Buffalo, Alberta, Canada.  This page will cover Building J2, which was built around 2014. The fire alarm system is mostly original, with an FACP replacement occurring in 2023.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Mircom FA-1000 conventional fire alarm system.  The panel is located at the centre hallway exit.  The system coding is temporal.  &amp;lt;br&amp;gt;This panel replaced a Mircom FA-101T.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All common areas have Mircom &amp;quot;Select-a-Horn/Strobe&amp;quot; FHS-340R horn/strobes (red, wall-mount, set to 15cd/electromechanical).  &amp;lt;br&amp;gt;All dorm rooms have Mircom FS-400-RR remote strobes (red, wall-mount, set to 15cd) paired with Mircom MH-S25WA silenceable mini-horns (white).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Mircom MS-401 conventional single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are System Sensor 5601A conventional 135°F fixed-temperature/rate-of-rise heat detectors in all service and dorm rooms.  &amp;lt;br&amp;gt;There are System Sensor 5604A conventional 194°F fixed-temperature heat detectors in all water heater and laundry rooms.  &amp;lt;br&amp;gt;There are Mircom SD-100-2WP conventional photoelectric smoke detectors throughout all corridors.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There is a Mircom MIX-4050 sync module synchronizing all strobes.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Mircom MP-300 end of line resistor plates on all circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Alberta]]&lt;br /&gt;
[[Category:Lodging]]&lt;/div&gt;</summary>
		<author><name>Alberta Fire Alarms</name></author>
	</entry>
</feed>