Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

Mail is now working! Feel free to request an account. Accounts are available to invested enthusiasts/technicians in the industry. :)

Recent changes

More actions

Track the most recent changes to the wiki on this page.

Recent changes options Show last 50 | 100 | 250 | 500 changes in last 1 | 3 | 7 | 14 | 30 days
Hide registered users | Hide anonymous users | Hide my edits | Show bots | Hide minor edits
Show new changes starting from 09:49, 15 May 2025
   
 
List of abbreviations:
N
This edit created a new page (also see list of new pages)
m
This is a minor edit
b
This edit was performed by a bot
(±123)
The page size changed by this number of bytes

14 May 2025

     22:05  R.T. Alderman School diffhist −8 Alberta Fire Alarms talk contribs Tag: Visual edit
     22:05  292135 Crosspointe Dr, Rocky View, AB diffhist −10 Alberta Fire Alarms talk contribs Tag: Visual edit
     22:03  Infinity at Marda Loop diffhist +2 Alberta Fire Alarms talk contribs Tag: Visual edit
     22:03  Edmonton Brewery District diffhist +2 Alberta Fire Alarms talk contribs Tag: Visual edit
     22:03  Belmont Secondary School diffhist −77 Alberta Fire Alarms talk contribs Tag: Visual edit
     22:00  Wyndham Garden Edmonton Airport diffhist +132 Alberta Fire Alarms talk contribs Tag: Visual edit
     21:59  Canadian Tire (Deerfoot City) diffhist +2 Alberta Fire Alarms talk contribs Tag: Visual edit
     21:59  545 Airways Road NE, Calgary diffhist +17 Alberta Fire Alarms talk contribs Tag: Visual edit
     21:59  50 Sage Hill Plaza NW, Calgary diffhist +2 Alberta Fire Alarms talk contribs Tag: Visual edit
     21:59  Ralph's Motorsports diffhist −1 Alberta Fire Alarms talk contribs Tag: Visual edit
     21:57  55 Sage Hill Plaza NW, Calgary, AB diffhist +2 Alberta Fire Alarms talk contribs (updating to ULC model) Tag: Visual edit
     21:57  Century Mile Racetrack and Casino diffhist +4 Alberta Fire Alarms talk contribs (ULC listed) Tag: Visual edit

12 May 2025

N    23:12  Willow Lodge T2 diffhist +1,910 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FA-1000 <br />FACP Location: Centre Hallway Exit <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Mircom <br />Date of last known Upgrade: N/A <br />Most Recent Known Modification: 2023, FACP<br /> Year Opened: 2018 |} '''Willow Lodge''' is a Suncor camp locate...")
N    23:12  Willow Lodge T1 diffhist +1,910 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FA-1000 <br />FACP Location: Centre Hallway Exit <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Mircom <br />Date of last known Upgrade: N/A <br />Most Recent Known Modification: 2023, FACP<br /> Year Opened: 2019 |} '''Willow Lodge''' is a Suncor camp locate...")
N    23:05  Willow Lodge S2 diffhist +1,945 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FA-1000 <br />FACP Location: Centre Hallway Exit <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Mircom <br />Date of last known Upgrade: N/A <br />Most Recent Known Modification: 2023, FACP<br /> Year Opened: Mid 2010s |} '''Willow Lodge''' is a Suncor camp l...")
N    23:04  Willow Lodge S1 diffhist +1,945 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FA-1000 <br />FACP Location: Centre Hallway Exit <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Mircom <br />Date of last known Upgrade: N/A <br />Most Recent Known Modification: 2023, FACP<br /> Year Opened: Mid 2010s |} '''Willow Lodge''' is a Suncor camp l...")
N    22:28  Willow Lodge R2 diffhist +2,086 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FA-1000<br />FACP Location: Centre Hallway Exit<br />System Type: Single-Stage Conventional<br/>System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR<br />System Coding: Temporal<br>Strobes Synchronized: Yes, Mircom<br />Date of last known Upgrade: N/A<br />Most Recent Known Modification: 2023, FACP<br /> Year Opened: 2008 |} '''Willow Lodge''' is a Suncor camp located in Woo...")
N    22:28  Willow Lodge R1 diffhist +1,988 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FA-1000<br />FACP Location: Centre Hallway Exit<br />System Type: Single-Stage Conventional<br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR<br />System Coding: Temporal<br>Strobes Synchronized: Yes, Mircom<br />Date of last known Upgrade: N/A<br />Most Recent Known Modification: 2023, FACP<br /> Year Opened: 2020s |} '''Willow Lodge''' is a Suncor camp located in W...")
N    22:28  Willow Lodge Q2 diffhist +2,125 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FA-1000<br />FACP Location: Centre Hallway Exit<br />System Type: Single-Stage Conventional<br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR<br />System Coding: Temporal<br>Strobes Synchronized: Yes, Mircom<br />Date of last known Upgrade: N/A<br />Most Recent Known Modification: 2023 (FACP)<br /> Year Opened: 2009 |} '''Willow Lodge''' is a Suncor camp located in W...")
N    22:28  Willow Lodge Q1 diffhist +2,410 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FA-1000<br />FACP Location: Centre Hallway Exit<br />System Type: Single-Stage Conventional<br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR<br />System Coding: Temporal<br>Strobes Synchronized: Yes, Mircom<br />Date of last known Upgrade: N/A<br />Most Recent Known Modification: 2023, FACP<br /> Year Opened: 2003 |} '''Willow Lodge''' is a Suncor camp located in Wo...")
N    22:24  Willow Lodge O1 diffhist +1,906 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FA-1000<br />FACP Location: Centre Hallway Exit<br />System Type: Single-Stage Conventional<br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR<br />System Coding: Temporal<br>Strobes Synchronized: Yes, Mircom<br />Date of last known Upgrade: N/A<br />Most Recent Known Modification: 2023, FACP<br /> Year Opened: 2017 |} '''Willow Lodge''' is a Suncor camp located in Wo...")
N    22:24  Willow Lodge N2 diffhist +2,205 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FA-1000 <br />FACP Location: Centre Hallway Exit <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Mircom <br />Date of last known Upgrade: N/A <br />Most Recent Known Modification: 2023, FACP <br /> Year Opened: 1990s |} '''Willow Lodge''' is a Suncor camp loca...")
N    22:24  Willow Lodge P1 diffhist +2,471 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FA-1000 <br />FACP Location: Centre Hallway Exit <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Mircom <br />Date of last known Upgrade: N/A <br />Most Recent Known Modification: 2023, FACP <br /> Year Opened: Early 2010s |} '''Willow Lodge''' is a Suncor ca...")
N    22:24  Willow Lodge P2 diffhist +2,176 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FA-1000 <br />FACP Location: Centre Hallway Exit <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Mircom <br />Date of last known Upgrade: N/A <br />Most Recent Known Modification: 2023, FACP <br /> Year Opened: Late 2000s |} '''Willow Lodge''' is a Suncor camp...")
N    22:21  Willow Lodge L2 diffhist +1,953 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FA-1000 <br />FACP Location: Centre Hallway Exit <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Mircom <br />Date of last known Upgrade: N/A <br />Most Recent Known Modification: 2023, FACP<br /> Year Opened: Early 2010s |} '''Willow Lodge''' is a Suncor camp...")
N    22:21  Willow Lodge M2 diffhist +2,084 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FA-1000 <br />FACP Location: Centre Hallway Exit <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Mircom <br />Date of last known Upgrade: N/A <br />Most Recent Known Modification: 2023, FACP<br /> Year Opened: Late 2000s |} '''Willow Lodge''' is a Suncor camp...")
N    22:21  Willow Lodge N1 diffhist +1,953 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FA-1000 <br />FACP Location: Centre Hallway Exit <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Mircom <br />Date of last known Upgrade: N/A <br />Most Recent Known Modification: 2023, FACP<br /> Year Opened: Early 2010s |} '''Willow Lodge''' is a Suncor camp...")
N    22:21  Willow Lodge O2 diffhist +2,017 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FA-1000<br />FACP Location: Centre Hallway Exit<br />System Type: Single-Stage Conventional<br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR<br />System Coding: Temporal<br>Strobes Synchronized: Yes, Mircom<br />Date of last known Upgrade: N/A<br />Most Recent Known Modification: 2023, FACP<br /> Year Opened: 2017 |} '''Willow Lodge''' is a Suncor camp located in Wo...")
N    22:20  Willow Lodge J2 diffhist +1,936 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FA-1000 <br />FACP Location: Centre Hallway Exit <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Mircom <br />Date of last known Upgrade: N/A <br />Most Recent Known Modification: 2023, FACP<br /> Year Opened: 2014 |} '''Willow Lodge''' is a Suncor camp locate...")
N    22:20  Willow Lodge K1 diffhist +2,094 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FA-1000 <br />FACP Location: Centre Hallway Exit <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Mircom <br />Date of last known Upgrade: 2015? <br />Most Recent Known Modification: 2023, FACP<br /> Year Opened: 2000s |} '''Willow Lodge''' is a Suncor camp loc...")
N    22:19  Willow Lodge L1 diffhist +1,955 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FA-1000 <br />FACP Location: Centre Hallway Exit <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Mircom <br />Date of last known Upgrade: N/A <br />Most Recent Known Modification: 2023, FACP<br /> Year Opened: Early 2010s |} '''Willow Lodge''' is a Suncor camp...")
N    22:19  Willow Lodge K2 diffhist +1,953 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FA-1000 <br />FACP Location: Centre Hallway Exit <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Mircom <br />Date of last known Upgrade: N/A <br />Most Recent Known Modification: 2023, FACP<br /> Year Opened: Early 2010s |} '''Willow Lodge''' is a Suncor camp...")
N    22:19  Willow Lodge M1 diffhist +1,953 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FA-1000 <br />FACP Location: Centre Hallway Exit <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Mircom <br />Date of last known Upgrade: N/A <br />Most Recent Known Modification: 2023, FACP<br /> Year Opened: Early 2010s |} '''Willow Lodge''' is a Suncor camp...")

11 May 2025

Nm   19:41  User:SK6820 diffhist +37 Twentytwo22 talk contribs (Creating user page for new user.)
Nm   19:41  User talk:SK6820 diffhist +312 Twentytwo22 talk contribs (Welcome!)
     19:41 User creation log User account SK6820 talk contribs was created by Twentytwo22 talk contribs and password was sent by email ‎
     17:28  Spruce Ridge Estates Building 3362/3364 diffhist +22 TwentyThree33 talk contribs (→‎Notification Appliances) Tag: Visual edit

8 May 2025

N    22:33  Ecole Chavigny diffhist +2,735 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Edwards iO1000<br />FACP Location: CACF Room <br />System Type: Single-Stage Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR (FACP) <br>24VDC (Boosters) <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Genesis <br />Date of last known Upgrade: 2018 <br />Most Recent Known Modification: N/A <br /> Year Opened: 1973 |} '''Ecole Chavigny''' is a scho...")
N    22:33  Jim Gauthier Chevrolet diffhist +1,458 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Notifier System 5000 <br />FACP Location: Main Showroom <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Continuous <br />Date of last known Upgrade: N/A <br />Most Recent Known Modification: 2010s (Smoke Detectors) <br /> Year Opened: 1990 |} '''Jim Gauthier Chevrolet''' is a General Motors car dealership...")
N    22:32  Willow Lodge G2 diffhist +1,872 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FA-1000 <br />FACP Location: Centre Hallway Exit <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Mircom <br />Date of last known Upgrade: N/A <br />Most Recent Known Modification: 2023, FACP<br /> Year Opened: 2022 |} '''Willow Lodge''' is a Suncor camp locate...")
N    22:32  Willow Lodge I2 diffhist +1,933 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FA-1000 <br />FACP Location: Centre Hallway Exit <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Mircom <br />Date of last known Upgrade: N/A <br />Most Recent Known Modification: 2023, FACP<br /> Year Opened: 2018 |} '''Willow Lodge''' is a Suncor camp locate...")
N    22:32  Willow Lodge I1 diffhist +1,933 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FA-1000 <br />FACP Location: Centre Hallway Exit <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Mircom <br />Date of last known Upgrade: N/A <br />Most Recent Known Modification: 2023, FACP<br /> Year Opened: 2011 |} '''Willow Lodge''' is a Suncor camp locate...")
N    22:28  Willow Lodge H1 diffhist +1,911 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FA-1000 <br />FACP Location: Centre Hallway Exit <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Mircom <br />Date of last known Upgrade: N/A <br />Most Recent Known Modification: 2023, FACP<br /> Year Opened: 2017 |} '''Willow Lodge''' is a Suncor camp locate...")
N    22:28  Willow Lodge H2 diffhist +1,872 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FA-1000 <br />FACP Location: Centre Hallway Exit <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Mircom <br />Date of last known Upgrade: N/A <br />Most Recent Known Modification: 2023, FACP<br /> Year Opened: 2022 |} '''Willow Lodge''' is a Suncor camp locate...")
N    22:27  Willow Lodge G1 diffhist +1,941 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FA-1000 <br />FACP Location: Centre Hallway Exit <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Mircom <br />Date of last known Upgrade: N/A <br />Most Recent Known Modification: 2023, FACP<br /> Year Opened: 2012? |} '''Willow Lodge''' is a Suncor camp locat...")
N    22:27  Willow Lodge J1 diffhist +1,910 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FA-1000 <br />FACP Location: Centre Hallway Exit <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Mircom <br />Date of last known Upgrade: N/A <br />Most Recent Known Modification: 2023, FACP<br /> Year Opened: 2017 |} '''Willow Lodge''' is a Suncor camp locate...")
N    22:27  Willow Lodge F2 diffhist +1,872 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FA-1000 <br />FACP Location: Centre Hallway Exit <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Mircom <br />Date of last known Upgrade: N/A <br />Most Recent Known Modification: 2023, FACP<br /> Year Opened: 2022 |} '''Willow Lodge''' is a Suncor camp locate...")
N    22:26  Willow Lodge F1 diffhist +1,911 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FA-1000 <br />FACP Location: Centre Hallway Exit <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Mircom <br />Date of last known Upgrade: N/A <br />Most Recent Known Modification: 2023, FACP<br /> Year Opened: 2017 |} '''Willow Lodge''' is a Suncor camp locate...")
N    22:26  Willow Lodge (Main Building)‎‎ 2 changes history +4,314 [Alberta Fire Alarms‎ (2×)]
     
22:26 (cur | prev) +12 Alberta Fire Alarms talk contribs (→‎FACP) Tag: Visual edit
N    
22:25 (cur | prev) +4,302 Alberta Fire Alarms talk contribs (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FleX-Net<br />FACP Location: Various <br />System Type: Single-Stage Networked Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Mircom <br />Date of last known Upgrade: 2024 <br />Most Recent Known Modification: 2020s (Some Detectors)<br /> Year Opened: 2012, 2018 |} '''Willow Lodge''' is a Su...")