Toggle search
Search
Toggle menu
129
57
47
11K
FireAlarmPedia
Navigation
Main page
Recent changes
Random page
All Pages
Facility Page Template
Contact Us
Special pages
Upload file
notifications
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.
user-interface-preferences
Personal tools
Talk
Contributions
Log in
We have switched hosting. Sorry for the recent downtime. :)
Editing
Sandman Signature Lethbridge Lodge
(section)
From FireAlarmPedia
Views
Read
Edit
Edit source
View history
associated-pages
Page
Discussion
More actions
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
==System Specifications== ====FACP==== The hotel is protected by an EST QuickStart QS4 addressable fire alarm system. The panel model and location are unconfirmed, but the model is based on the initiating and signaling devices. The system runs EST’s SIGA addressable protocol, and the system coding is temporal. ====Notification Appliances==== The notification appliances in most of the hotel are EST “Genesis” G1R-HDVM horn/strobes (red, wall-mount, no FIRE, set to 15cd). Some are mounted on G1RT-FIRE trim plates, and some are flush-mounted with no trim plate. One area of the hotel has a horn/strobe missing the strobe assembly. The guest rooms have EST SIGA-PS addressable photoelectric smoke detectors mounted on SIGA-AB4G sounder bases. ===Initiating Devices=== ====Pull Stations==== All pull stations are EST SIGA-270 addressable single-action pull stations. ====Automatic Detection Devices ==== There are EST SIGA-PS addressable photoelectric smoke detectors throughout the hotel. In most areas, they are mounted on SIGA-SB bases, but in the guest rooms, they are mounted on EST SIGA-AB4G sounder bases. ==== EOLs ==== There are Edwards EOL-P1 end-of-line resistor plates on all signal circuits. [[Category:Facilities]] [[Category:Lethbridge]] [[Category:Hotels]]
Summary:
Please note that all contributions to FireAlarmPedia may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see
FireAlarmPedia:Copyrights
for details).
Do not submit copyrighted work without permission!
Cancel
Editing help
(opens in new window)