Toggle search
Search
Toggle menu
133
57
47
11.4K
FireAlarmPedia
Navigation
Main page
Recent changes
Random page
All Pages
Facility Page Template
Contact Us
Special pages
Upload file
notifications
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.
user-interface-preferences
Personal tools
Talk
Contributions
Log in
We have switched hosting. Sorry for the recent downtime. :)
Editing
Staybridge Suites Oakville Burlington
(section)
From FireAlarmPedia
Views
Read
Edit
Edit source
View history
associated-pages
Page
Discussion
More actions
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
==System Specifications== ====FACP==== The hotel is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located in the main sprinkler room, located on the northeast side of the building. The system runs Mircom’s CLIP addressable protocol, and the system coding is temporal.. =====Annunciators===== There is a Mircom RAM-1032TZDS annunciator paired with a Mircom RAX-1048TZDS annunciator at the front entrance. Both modules are mounted in a Mircom BB-1002 enclosure. ====Notification Appliances==== All common areas of the hotel have Mircom “Select-A-Horn/Strobe” FHS-240W horn/strobes (white, wall-mount). <br>The guest rooms have Mircom MH-25W mini-horns (white, wall-mount), with FIRE stickers on them. ===Initiating Devices=== ====Pull Stations==== All pull stations are Mircom MS-701AD addressable single-action pull stations. ====Automatic Detection Devices==== There are Mircom MIX-2251BA addressable photoelectric smoke detectors throughout all common areas, mounted on System Sensor B210LPA bases. ====Modules==== There are Mircom MIX-M500MA addressable monitor modules supervising the sprinkler system’s tamper and flow switches. <br>There are Mircom MIX-M500RA addressable relay modules serving various purposes. <br>There are System Sensor M500XA isolator modules on the SLC. ====EOLs==== There are Mircom MP-300 end of line resistor plates on all sprinkler and Class-B signal circuits. [[Category:Ontario]] [[Category:Hotels]]
Summary:
Please note that all contributions to FireAlarmPedia may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see
FireAlarmPedia:Copyrights
for details).
Do not submit copyrighted work without permission!
Cancel
Editing help
(opens in new window)