Toggle search
Search
Toggle menu
129
57
47
11K
FireAlarmPedia
Navigation
Main page
Recent changes
Random page
All Pages
Facility Page Template
Contact Us
Special pages
Upload file
notifications
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.
user-interface-preferences
Personal tools
Talk
Contributions
Log in
We have switched hosting. Sorry for the recent downtime. :)
Editing
Walmart Supercentre
(Wainwright)
(section)
From FireAlarmPedia
Views
Read
Edit
Edit source
View history
associated-pages
Page
Discussion
More actions
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
== System Specifications (2007-present) == ==== FACP ==== The building is protected by an Edwards iO1000 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Edwards’ Signature addressable protocol, and the system coding is temporal. <br> The iO1000 replaced the original EST QuickStart QS1 in the early 2020s. ===== Power Supplies ===== There is an Edwards BPS10C 10-amp booster panel on the system. ==== Notification Appliances ==== Most notification appliances are Edwards “Genesis” G1R-HDVM horn/strobes (red, wall-mount, no marking, set to 15cd). <br>There are Edwards G1R-VM remote strobes (red, wall-mount, no marking, set to 15cd) in the washrooms and in the main storefront. <br>Throughout the store, the devices are mounted on poles, with 2 horn/strobes and 2 remote strobes facing opposite each other. === Initiating Devices === ==== Pull Stations ==== All pull stations are EST SIGA-270 addressable single-action pull stations. ==== Automatic Detection Devices ==== None noticed. ==== Modules ==== There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system’s tamper and flow switches. <br> There are EST SIGA-CR addressable relay modules serving various purposes. <br> There is an EST SIGA-CC1 control module for supervising and triggering the booster panel. ==== EOLs ==== There are Edwards EOL-P1 end-of-line resistor plates on all sprinkler and signal circuits. [[Category:Wainwright]] [[Category:Retail Stores]]
Summary:
Please note that all contributions to FireAlarmPedia may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see
FireAlarmPedia:Copyrights
for details).
Do not submit copyrighted work without permission!
Cancel
Editing help
(opens in new window)