Toggle search
Search
Toggle menu
129
57
47
11K
FireAlarmPedia
Navigation
Main page
Recent changes
Random page
All Pages
Facility Page Template
Contact Us
Special pages
Upload file
notifications
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.
user-interface-preferences
Personal tools
Talk
Contributions
Log in
We have switched hosting. Sorry for the recent downtime. :)
Editing
Costco Wholesale
(Deerfoot Meadows)
(section)
From FireAlarmPedia
Views
Read
Edit
Edit source
View history
associated-pages
Page
Discussion
More actions
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
==System Specifications (Liquor Store)== {| style="float:right;border:2px solid black" |- ! System Specifications (Liquor Store) |- | |- | FACP: Notifier AFP-200 <br />FACP Location: Main Entrance Vestibule <br />System Type: Single-Stage Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br>Strobes Synchronized: No <br />Date of last known Upgrade: N/A <br />Year Opened: 2006 |} ====FACP==== The liquor store is protected by a Notifier AFP-200 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Notifier's CLIP addressable protocol, and the system coding is temporal. ====Notification Appliances==== All notification appliances are System Sensor "SpectrAlert" P2415A horn/strobes (red, wall-mount, 15cd). ===Initiating Devices=== ====Pull Stations==== All pull stations are Notifier MPS-950B conventional single-action pull stations, wired to Notifier FMM-101A addressable monitor modules. ====Automatic Detection Devices==== None noticed. ====Modules==== There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system's tamper and flow switches. ====EOLs==== There are Notifier EOL-CR end of line resistor plates on all sprinkler and signal circuits. [[Category:Calgary]] [[Category:Retail Stores]]
Summary:
Please note that all contributions to FireAlarmPedia may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see
FireAlarmPedia:Copyrights
for details).
Do not submit copyrighted work without permission!
Cancel
Editing help
(opens in new window)