Toggle search
Search
Toggle menu
129
57
47
11K
FireAlarmPedia
Navigation
Main page
Recent changes
Random page
All Pages
Facility Page Template
Contact Us
Special pages
Upload file
notifications
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.
user-interface-preferences
Personal tools
Talk
Contributions
Log in
We have switched hosting. Sorry for the recent downtime. :)
Editing
Walmart Supercentre
(Medicine Hat)
(section)
From FireAlarmPedia
Views
Read
Edit
Edit source
View history
associated-pages
Page
Discussion
More actions
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
==Former System Specifications (2008-2020s)== Please note that all former specifications are assumed, and should not be used for official purposes. {| style="float:right;border:2px solid black" |- ! Former System Specifications |- | |- | FACP: EST QuickStart QS1 <br />FACP Location: Home & Pharm. Entrance Vestibule <br />System Type: Single-Stage Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, per-NAC <br />Date of last known Upgrade: N/A <br/> Year Installed: 2008 <br />Year Decommissioned: 2020s |} ====FACP==== The building was protected by an EST QuickStart QS1 addressable fire alarm system. The panel was located in the Home & Pharmacy entrance vestibule. The system ran EST’s Signature addressable protocol, and the system coding was temporal. ====Notification Appliances==== Most notification appliances were Edwards “Genesis” G1R-HDVM horn/strobes (red, wall-mount, no marking, set to 15cd). <br>There were Edwards G1R-VM remote strobes (red, wall-mount, no marking, set to 15cd) in the washrooms and in the main storefront. <br>Throughout the store, the devices were mounted on poles, with 2 horn/strobes and 2 remote strobes facing opposite each other. <br>The notification appliances were not replaced during the 2020s system upgrade. ===Initiating Devices=== ====Pull Stations==== All pull stations were EST SIGA-270 addressable single-action pull stations. ====Automatic Detection Devices==== Not known. ====Modules==== There were EST SIGA-CT1 addressable monitor modules supervising the kitchen suppression systems, and the sprinkler system’s tamper and flow switches. <br>There were EST SIGA-CR addressable relay modules serving various purposes. ====EOLs==== There were Edwards EOL-P1 end of line resistor plates on all kitchen suppression, sprinkler and signal circuits. <br>These were not replaced during the 2020s system upgrade. [[Category:Alberta]] [[Category:Retail Stores]]
Summary:
Please note that all contributions to FireAlarmPedia may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see
FireAlarmPedia:Copyrights
for details).
Do not submit copyrighted work without permission!
Cancel
Editing help
(opens in new window)