'''1611 36 Ave SW''' is the address given to a walk-up apartment building in Calgary, AB. It was built in 1957, and the fire alarm system was upgraded in the late 1980s.
'''1611 36 Ave SW''' is the address given to a walk-up apartment building in Calgary, AB. It was built in 1957, and the fire alarm system was upgraded in the late 1980s.
Line 18: Line 18:
All pull stations are Edwards 275-C111 conventional single-action pull stations.
All pull stations are Edwards 275-C111 conventional single-action pull stations.
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
None noticed
None noticed.
 
==== EOLs ====
There are Edwards EOL-P1 end of line resistor plates on all circuits.
[[Category:Calgary]]
[[Category:Calgary]]
[[Category:Residential]]
[[Category:Residential]]

Latest revision as of 11:52, 19 August 2024

System Specifications
FACP: Edwards 1527
FACP Location: Unknown
System Type: Single-Stage Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Continuous
Date of last known Upgrade: Late 1980s
Year Opened: 1957

1611 36 Ave SW is the address given to a walk-up apartment building in Calgary, AB. It was built in 1957, and the fire alarm system was upgraded in the late 1980s.

System Specifications (late 1980s-present)

  • Please note that some system details are unconfirmed. This page should not be used for official purposes.

FACP

The building is protected by an Edwards 1527 conventional fire alarm system. The panel location is unknown, and it is unknown if it was replaced. The system coding is continuous.

Notification Appliances

All notification appliances are Edwards “Durabel” 6100D vibrating bells (6” gong).

Initiating Devices

Pull Stations

All pull stations are Edwards 275-C111 conventional single-action pull stations.

Automatic Detection Devices

None noticed.

EOLs

There are Edwards EOL-P1 end of line resistor plates on all circuits.