More actions
(Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FX-2000 <br />FACP Location: Fire Hall Apparatus Room <br />System Type: Addre...") |
No edit summary |
||
Line 5: | Line 5: | ||
| | | | ||
|- | |- | ||
| FACP: Mircom FX-2000 <br />FACP Location: Fire Hall Apparatus Room <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: No <br />Date of last known Upgrade: 2010s <br />Year Opened: 1965 | | FACP: Mircom FX-2000 <br />FACP Location: Fire Hall Apparatus Room <br />System Type: Single-Stage Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: No <br />Date of last known Upgrade: 2010s <br />Year Opened: 1965 | ||
|} | |} | ||
'''1928 14 Avenue Northwest''' is the address of a building in Calgary, Alberta, Canada. The building contains Calgary Fire Department Station 10, and the Hounsfield Heights-Briar Hill Community Centre. The building opened in 1965, and the fire alarm system was upgraded in the 2010s. | |||
'''1928 14 Avenue Northwest''' is the address of a building in Calgary, Alberta, Canada. | |||
==System Specifications (2010s-present)== | ==System Specifications (2010s-present)== | ||
====FACP==== | ====FACP==== | ||
The building is protected by a Mircom FX-2000 addressable fire alarm system. | The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located in the back apparatus room of the fire station. The system runs Mircom’s CLIP addressable protocol, and the system coding is temporal. | ||
=====Annunciators===== | =====Annunciators===== | ||
There is a Mircom RAX-1032TZDS annunciator in the main entrance vestibule. | There is a Mircom RAX-1032TZDS annunciator in the main entrance vestibule. | ||
====Notification Appliances==== | ====Notification Appliances==== | ||
All notification appliances are Mircom “Select-A-Horn/Strobe” FHS-340W horn/strobes (white, wall-mount, set to electromechanical/15cd). | All notification appliances are Mircom “Select-A-Horn/Strobe” FHS-340W horn/strobes (white, wall-mount, set to electromechanical/15cd). | ||
===Initiating Devices=== | ===Initiating Devices=== | ||
====Pull Stations==== | ====Pull Stations==== | ||
All pull stations are Mircom MS-401AD addressable single-action pull stations. | All pull stations are Mircom MS-401AD addressable single-action pull stations. | ||
====Automatic Detection Devices==== | ====Automatic Detection Devices==== | ||
There are Mircom MIX-2251BA addressable photoelectric smoke detectors in some areas, mounted on Mircom B710LPA bases. | There are Mircom MIX-2251BA addressable photoelectric smoke detectors in some areas, mounted on Mircom B710LPA bases. | ||
====Modules==== | ====Modules==== | ||
There are Mircom MIX-M500MA addressable monitor modules supervising the sprinkler system’s tamper and flow switches. | There are Mircom MIX-M500MA addressable monitor modules supervising the sprinkler system’s tamper and flow switches. | ||
==== EOLs ==== | |||
There are Mircom MP-300 end of line resistor plates on all sprinkler and signal circuits. | |||
[[Category:Calgary]] | |||
[[Category:Emergency Services]] | |||
[[Category:Community Centres]] |
Latest revision as of 12:00, 19 August 2024
System Specifications |
---|
FACP: Mircom FX-2000 FACP Location: Fire Hall Apparatus Room System Type: Single-Stage Addressable System Line Voltage: 120VAC NAC Voltage: 24VFWR System Coding: Temporal Strobes Synchronized: No Date of last known Upgrade: 2010s Year Opened: 1965 |
1928 14 Avenue Northwest is the address of a building in Calgary, Alberta, Canada. The building contains Calgary Fire Department Station 10, and the Hounsfield Heights-Briar Hill Community Centre. The building opened in 1965, and the fire alarm system was upgraded in the 2010s.
System Specifications (2010s-present)[edit | edit source]
FACP[edit | edit source]
The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located in the back apparatus room of the fire station. The system runs Mircom’s CLIP addressable protocol, and the system coding is temporal.
Annunciators[edit | edit source]
There is a Mircom RAX-1032TZDS annunciator in the main entrance vestibule.
Notification Appliances[edit | edit source]
All notification appliances are Mircom “Select-A-Horn/Strobe” FHS-340W horn/strobes (white, wall-mount, set to electromechanical/15cd).
Initiating Devices[edit | edit source]
Pull Stations[edit | edit source]
All pull stations are Mircom MS-401AD addressable single-action pull stations.
Automatic Detection Devices[edit | edit source]
There are Mircom MIX-2251BA addressable photoelectric smoke detectors in some areas, mounted on Mircom B710LPA bases.
Modules[edit | edit source]
There are Mircom MIX-M500MA addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
EOLs[edit | edit source]
There are Mircom MP-300 end of line resistor plates on all sprinkler and signal circuits.