Atlantic Superstore (Elmsdale): Difference between revisions

From FireAlarmPedia
(FUCKING APOSTROPHE!!!!!!!!! BLUE BOXES!!!!!!!!!)
No edit summary
 
(5 intermediate revisions by 3 users not shown)
Line 5: Line 5:
|  
|  
|-
|-
| FACP: EST iO500 <br /> FACP Location: Main Entrance Vestibule <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br /> System Coding: Temporal? <br> Strobes Synchronized: N/A <br />Date of last known Upgrade: 2013? <br />Year Opened: 1990s
| FACP: EST iO500 <br /> FACP Location: Main Entrance Vestibule <br />System Type: Single-Stage Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br /> System Coding: Temporal? <br> Strobes Synchronized: N/A <br />Date of last known Upgrade: 2013? <br />Year Opened: 1999
|}
|}
 
'''Atlantic Superstore''' is a chain of grocery stores owned by Loblaws. They have locations in Nova Scotia, New Brunswick, and PEI. This particular store is located at 295 Highway NS-214, Elmsdale, Nova Scotia. The building was built in 1999, and the fire alarm system is mostly original.
'''Atlantic Superstore''' is a chain of grocery stores owned by Loblaws. They have locations in Nova Scotia, New Brunswick, and PEI. This particular store is located in Elmsdale, Nova Scotia. The building was likely built in the mid 1990s, and the fire alarm system is mostly original.
==System Specifications==
==System Specifications==
====FACP====
====FACP====
The building is protected by an EST iO500 addressable fire alarm system. The panel is located in the main entrance vestibule. This panel likely replaced an Edwards 6632 or ESA2000. The system runs EST’s Signature-series addressable protocol, and the system coding is likely temporal.
The building is protected by an EST iO500 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs EST’s Signature addressable protocol, and the system coding is likely temporal.
 
The iO500 replaced an EST 6632.
====Notification Appliances====
====Notification Appliances====
The storefront has General Signal MB10-24 motor bells (10” gong). There is one Edwards MB10-24 motor bell (10” gong) above the seafood counter as a deficiency replacement. The staff areas and the first floor elevator lobby have General Signal MB6-24 motor bells (6” gong). These are also known as the General Signal 74303.
The storefront has General Signal MB10-24 motor bells (10” gong).  
 
There is one Edwards MB10-24 motor bell (10” gong) above the seafood counter as a deficiency replacement.  
 
The staff areas and the first floor elevator lobby have General Signal MB6-24 motor bells (6” gong).
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations are EST SIGC-270B addressable bilingual single-action pull stations.
All pull stations are EST SIGC-270B addressable bilingual single-action pull stations.
====Automatic Detection Devices====
====Automatic Detection Devices====
The storefront is protected by a sprinkler system with waterflow detection. As such, no automatic detection devices are present.
None noticed.
==== Modules ====
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches.
 
==== EOLs ====
There are Edwards EOL-P1 end of line resistor plates on all sprinkler and signal circuits.
[[Category:Nova Scotia]]
[[Category:Retail Stores]]

Latest revision as of 11:37, 8 September 2024

System Specifications
FACP: EST iO500
FACP Location: Main Entrance Vestibule
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Temporal?
Strobes Synchronized: N/A
Date of last known Upgrade: 2013?
Year Opened: 1999

Atlantic Superstore is a chain of grocery stores owned by Loblaws. They have locations in Nova Scotia, New Brunswick, and PEI. This particular store is located at 295 Highway NS-214, Elmsdale, Nova Scotia. The building was built in 1999, and the fire alarm system is mostly original.

System Specifications[edit | edit source]

FACP[edit | edit source]

The building is protected by an EST iO500 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs EST’s Signature addressable protocol, and the system coding is likely temporal.

The iO500 replaced an EST 6632.

Notification Appliances[edit | edit source]

The storefront has General Signal MB10-24 motor bells (10” gong).

There is one Edwards MB10-24 motor bell (10” gong) above the seafood counter as a deficiency replacement.

The staff areas and the first floor elevator lobby have General Signal MB6-24 motor bells (6” gong).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are EST SIGC-270B addressable bilingual single-action pull stations.

Automatic Detection Devices[edit | edit source]

None noticed.

Modules[edit | edit source]

There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches.

EOLs[edit | edit source]

There are Edwards EOL-P1 end of line resistor plates on all sprinkler and signal circuits.