Line 6: | Line 6: | ||
| | | | ||
|- | |- | ||
| FACP: Siemens TXL-1000 <br />FACP Location: Electrical Room? <br />System Type: Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal? <br />Date of last known Upgrade: Late 2010s <br />Year Opened: 1990 | | FACP: Siemens TXL-1000 <br />FACP Location: Electrical Room? <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal? <br />Date of last known Upgrade: Late 2010s <br />Year Opened: 1990 | ||
|} | |} | ||
'''Bertram Place''' is a 55+ apartment building located 1385 Bertram St, Kelowna, BC. It was built in 1990, and the fire alarm system is mostly original, with parts replaced as deficiencies occur. | '''Bertram Place''' is a 55+ apartment building located 1385 Bertram St, Kelowna, BC. It was built in 1990, and the fire alarm system is mostly original, with parts replaced as deficiencies occur. | ||
== System Specifications (1990-present) == | == System Specifications (1990-present) == | ||
==== FACP ==== | ==== FACP ==== | ||
The building is protected by a Siemens TXL-1000 conventional fire alarm system. The panel is likely located in an electrical room. The system coding is likely temporal. | The building is protected by a Siemens TXL-1000 conventional fire alarm system. The panel is likely located in an electrical room. The system coding is likely temporal. | ||
===== Annunciators ===== | ===== Annunciators ===== | ||
There is a Mircom RAM-1032TZDS LED annunciator at the entrance, mounted in Siemens-branded cabinet. | There is a Mircom RAM-1032TZDS LED annunciator at the entrance, mounted in Siemens-branded cabinet. | ||
==== Notification Appliances ==== | ==== Notification Appliances ==== | ||
All notification appliances are Edwards 439D-10AWC vibrating bells (10” gong). | All notification appliances are Edwards 439D-10AWC vibrating bells (10” gong). | ||
=== Initiating Devices === | === Initiating Devices === | ||
==== Pull Stations ==== | ==== Pull Stations ==== | ||
All pull stations are Edwards 275-C111 conventional single-action pull stations. | All pull stations are Edwards 275-C111 conventional single-action pull stations. | ||
==== Automatic Detection Devices ==== | ==== Automatic Detection Devices ==== | ||
There are Edwards 6250C conventional ionization smoke detectors throughout. <br> Some areas, including all units, have Edwards 281C conventional 135-degree fixed-temperature/rate-of-rise heat detectors. <br> There are System Sensor 5601A conventional 135-degree fixed-temperature/rate-of-rise heat detectors as deficiency replacements. | There are Edwards 6250C conventional ionization smoke detectors throughout. <br> Some areas, including all units, have Edwards 281C conventional 135-degree fixed-temperature/rate-of-rise heat detectors. <br> There are System Sensor 5601A conventional 135-degree fixed-temperature/rate-of-rise heat detectors as deficiency replacements. | ||
==== EOLs ==== | |||
There are Edwards EOL-P1 end of line resistor plates on all circuits. | |||
[[Category:British Columbia]] | |||
[[Category:Residential]] |
Latest revision as of 14:18, 8 September 2024
System Specifications |
---|
FACP: Siemens TXL-1000 FACP Location: Electrical Room? System Type: Single-Stage Conventional System Line Voltage: 120VAC NAC Voltage: 24VFWR System Coding: Temporal? Date of last known Upgrade: Late 2010s Year Opened: 1990 |
Bertram Place is a 55+ apartment building located 1385 Bertram St, Kelowna, BC. It was built in 1990, and the fire alarm system is mostly original, with parts replaced as deficiencies occur.
System Specifications (1990-present)[edit | edit source]
FACP[edit | edit source]
The building is protected by a Siemens TXL-1000 conventional fire alarm system. The panel is likely located in an electrical room. The system coding is likely temporal.
Annunciators[edit | edit source]
There is a Mircom RAM-1032TZDS LED annunciator at the entrance, mounted in Siemens-branded cabinet.
Notification Appliances[edit | edit source]
All notification appliances are Edwards 439D-10AWC vibrating bells (10” gong).
Initiating Devices[edit | edit source]
Pull Stations[edit | edit source]
All pull stations are Edwards 275-C111 conventional single-action pull stations.
Automatic Detection Devices[edit | edit source]
There are Edwards 6250C conventional ionization smoke detectors throughout.
Some areas, including all units, have Edwards 281C conventional 135-degree fixed-temperature/rate-of-rise heat detectors.
There are System Sensor 5601A conventional 135-degree fixed-temperature/rate-of-rise heat detectors as deficiency replacements.
EOLs[edit | edit source]
There are Edwards EOL-P1 end of line resistor plates on all circuits.