Crowfoot Library: Difference between revisions

From FireAlarmPedia
mNo edit summary
 
(8 intermediate revisions by 3 users not shown)
Line 5: Line 5:
|  
|  
|-
|-
| FACP: Notifier NFS-320C <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />Date of last known Upgrade: 2014 <br />Year Opened: 2004
| FACP: Notifier NFS-320C <br /> FACP Location: Main Entrance <br> System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br /> System Coding: Temporal <br> Strobes Synchronized: Yes <br> Date of last known Upgrade: 2014 <br />Year Opened: 2004
|}
|}
 
The '''Crowfoot Library''' is a public library located at 8665 Nose Hill Drive Northwest, in Calgary, Alberta, Canada. It is part of the Calgary Public Library. The building opened in 2004, and the fire alarm system is mostly from 2014. All of the notification appliances are original.  
The '''Crowfoot Library''' is a public library in Crowfoot, NW Calgary. It is part of the Calgary Public Library, and it was built in 2004, but the current system is from 2014. All of the notification appliances are original.  
 
== System Specifications (2014-present) ==
== System Specifications (2014-present) ==
==== FACP ====
==== FACP ====
 
The building is protected by a Notifier NFS-320C addressable fire alarm system. The panel is located in the main entrance vestibule, between two book return slots. The system runs Notifier's FlashScan addressable protocol, and the system coding is temporal.
The fire alarm control panel is a Notifier NFS-320C (addressable) installed in 2014. It replaced a Simplex 4010 from 2004. The panel is located at the entrance, in between two book return slots.  
 
==== Notification Appliances ====
==== Notification Appliances ====
 
All notification appliances are the original System Sensor "SpectrAlert" P2415A horn/strobes (red, wall-mount, 15cd). These are mounted on the ceiling throughout the library.
The notification appliances are original from 2004. They are System Sensor "SpectrAlert" P1224MC (red, wall) horn/strobes. Though they are wall orientated, they are on the ceilings for unknown reasons. These are the only devices that remained from the system change.
 
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
 
All pull stations are Notifier NBG-12LX addressable dual-action pull stations.
All of the pull stations are Notifier NBG-12LX (addressable). They are flashing green due to the FlashScan technology in ONYX series panels. Installed 2014.
 
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
There are Notifier FSP-851A addressable photoelectric smoke detectors throughout the library, mounted on System Sensor B210LPA low-profile bases. There is also a sprinkler system with waterflow detection.
==== Modules ====
There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system's tamper and flow switches.


The smoke detectors are Notifier FSP-851 addressable photoelectric smoke detectors with FlashScan, also from 2014.
==== EOLs ====
There are Notifier EOL-CR end-of-line resistor plates on all sprinkler and signal circuits.


== Former System Specifications ==
== Former System Specifications (2004-2014) ==
{| style="float:right;border:2px solid black"
{| style="float:right;border:2px solid black"
|-
|-
! System Specifications
! Former System Specifications
|-
|-
|  
|  
|-
|-
| FACP: Simplex 4010 <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />Date of last known Upgrade: N/A <br />Year Decommissioned: 2014
| FACP: Simplex 4010 <br /> FACP Location: Main Entrance <br> System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br /> System Coding: Temporal <br> Strobes Synchronized: No <br> Date of last known Upgrade: N/A <br />Year Decommissioned: 2014
|}
|}
==== FACP ====
==== FACP ====
 
The building was protected by a Simplex 4010 addressable fire alarm system. The panel was located in the main entrance vestibule. The system ran Simplex's IDNet addressable protocol, and the system coding was temporal.
The fire alarm panel was a Simplex 4010 (addressable). It was installed in 2004 when the library was built. The system was replaced in 2014 with a Notifier NFS-320C system.
 
==== Notification Appliances ====
==== Notification Appliances ====
 
All notification appliances were System Sensor "SpectrAlert" P2415A horn/strobes (red, wall-mount, 15cd). These are still in use on the Notifier system, and were likely installed due to customer preference.  
The notification appliances were System Sensor "SpectrAlert" P1224MC horn/strobes. They were installed in 2004 when the library was built, and still remain there on the Notifier system today. It is unknown why the installers went with System Sensor horn/strobes.  
 
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
 
All pull stations were Simplex 4099-9001 addressable single-action pull stations.
The pull stations were Simplex 4099-9001 addressable, single-action T-bars. Removed in 2014 when the Notifier system was installed due to not being compatible.
 
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
There were Simplex "TrueAlarm" 4098-9714 addressable photoelectric smoke detectors throughout the library, mounted on Simplex 4098-9792 addressable bases. There is also a sprinkler system with waterflow detection.
==== Modules ====
There were Simplex 4090-9001 addressable monitor modules supervising the sprinkler system's tamper and flow switches.


The smoke detectors were Simplex 4098-9714 "TrueAlarm" addressable, photoelectric smoke detectors. Removed in 2014 when the Notifier system was installed due to not being compatible.
==== EOLs ====
There were Simplex 2081-9040C end-of-line resistor plates on all sprinkler and signal circuits.
[[Category:Calgary]]
[[Category:Libraries]]

Latest revision as of 10:01, 24 September 2024

System Specifications
FACP: Notifier NFS-320C
FACP Location: Main Entrance
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: Yes
Date of last known Upgrade: 2014
Year Opened: 2004

The Crowfoot Library is a public library located at 8665 Nose Hill Drive Northwest, in Calgary, Alberta, Canada. It is part of the Calgary Public Library. The building opened in 2004, and the fire alarm system is mostly from 2014. All of the notification appliances are original.

System Specifications (2014-present)[edit | edit source]

FACP[edit | edit source]

The building is protected by a Notifier NFS-320C addressable fire alarm system. The panel is located in the main entrance vestibule, between two book return slots. The system runs Notifier's FlashScan addressable protocol, and the system coding is temporal.

Notification Appliances[edit | edit source]

All notification appliances are the original System Sensor "SpectrAlert" P2415A horn/strobes (red, wall-mount, 15cd). These are mounted on the ceiling throughout the library.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are Notifier NBG-12LX addressable dual-action pull stations.

Automatic Detection Devices[edit | edit source]

There are Notifier FSP-851A addressable photoelectric smoke detectors throughout the library, mounted on System Sensor B210LPA low-profile bases. There is also a sprinkler system with waterflow detection.

Modules[edit | edit source]

There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system's tamper and flow switches.

EOLs[edit | edit source]

There are Notifier EOL-CR end-of-line resistor plates on all sprinkler and signal circuits.

Former System Specifications (2004-2014)[edit | edit source]

Former System Specifications
FACP: Simplex 4010
FACP Location: Main Entrance
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: No
Date of last known Upgrade: N/A
Year Decommissioned: 2014

FACP[edit | edit source]

The building was protected by a Simplex 4010 addressable fire alarm system. The panel was located in the main entrance vestibule. The system ran Simplex's IDNet addressable protocol, and the system coding was temporal.

Notification Appliances[edit | edit source]

All notification appliances were System Sensor "SpectrAlert" P2415A horn/strobes (red, wall-mount, 15cd). These are still in use on the Notifier system, and were likely installed due to customer preference.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations were Simplex 4099-9001 addressable single-action pull stations.

Automatic Detection Devices[edit | edit source]

There were Simplex "TrueAlarm" 4098-9714 addressable photoelectric smoke detectors throughout the library, mounted on Simplex 4098-9792 addressable bases. There is also a sprinkler system with waterflow detection.

Modules[edit | edit source]

There were Simplex 4090-9001 addressable monitor modules supervising the sprinkler system's tamper and flow switches.

EOLs[edit | edit source]

There were Simplex 2081-9040C end-of-line resistor plates on all sprinkler and signal circuits.