Drumheller Memorial Arena: Difference between revisions

From FireAlarmPedia
(ass)
 
No edit summary
 
(One intermediate revision by the same user not shown)
Line 5: Line 5:
|  
|  
|-
|-
| FACP: Simplex 4010 <br />FACP Location: Main Exit Vestibule <br />System Type: Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br>Strobes Synchronized: No <br />Date of last known Upgrade: 2002 <br />Year Opened: 1967
| FACP: Simplex 4010 <br />FACP Location: Main Exit Vestibule <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br>Strobes Synchronized: No <br />Date of last known Upgrade: 2002 <br />Year Opened: 1967
|}
|}
 
The '''Drumheller Memorial Arena''' is an 1800-seat hockey arena located at 100 Riverside Dr. W, Drumheller, Alberta. The arena is home to the Drumheller Dragons of the Alberta Junior Hockey League (AJHL). The arena was built in 1967, and was renovated in 2002. The fire alarm system was upgraded in 2002, and the panel was replaced in the late 2000s.
The '''Drumheller Memorial Arena''' is an 1800-seat hockey arena located at 100 Riverside Dr. W, Drumheller, Alberta. The arena is home to the Drumheller Dragons of the Alberta Junior Hockey League (AJHL). The arena was built in 1967, and was renovated in 2002. The fire alarm system was upgraded in 2002, and the panel was replaced in the late 2000s.
 
==System Specifications (2002-present)==
==System Specifications (2002-present)==
This information is accurate to 2017, however some information cannot be confirmed. This page should not be used for official purposes.
This information is accurate to 2017, however some information cannot be confirmed. This page should not be used for official purposes.
====FACP====
====FACP====
The building is protected by a Simplex 4010 conventional fire alarm system. The panel is located in the main exit vestibule. This panel has Simplex 4090-9001 and 4090-9101 addressable monitor modules supervising all conventional zones. The system coding is temporal.
The building is protected by a Simplex 4010 conventional fire alarm system. The panel is located in the main exit vestibule. This panel has Simplex 4090-9001 and 4090-9101 addressable monitor modules supervising all conventional zones. The system coding is temporal.
 
====Notification Appliances====
====Notification Appliances====
All notification appliances are Mirtone “Integrity” INT-5AT horn/strobes (red, wall-mount, 15cd).
All notification appliances are Mirtone “Integrity” INT-5AT horn/strobes (red, wall-mount, 15cd).
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations are Mirtone 73353 conventional single-action pull stations.
All pull stations are Mirtone 73353 conventional single-action pull stations.
====Automatic Detection Devices====
====Automatic Detection Devices====
There are likely System Sensor C2W-BA conventional photoelectric smoke detectors in most areas.
There are likely System Sensor C2W-BA conventional photoelectric smoke detectors in most areas.
[[Category:Alberta]]
[[Category:Arenas]]

Latest revision as of 16:57, 25 September 2024

System Specifications
FACP: Simplex 4010
FACP Location: Main Exit Vestibule
System Type: Single-Stage Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: No
Date of last known Upgrade: 2002
Year Opened: 1967

The Drumheller Memorial Arena is an 1800-seat hockey arena located at 100 Riverside Dr. W, Drumheller, Alberta. The arena is home to the Drumheller Dragons of the Alberta Junior Hockey League (AJHL). The arena was built in 1967, and was renovated in 2002. The fire alarm system was upgraded in 2002, and the panel was replaced in the late 2000s.

System Specifications (2002-present)[edit | edit source]

This information is accurate to 2017, however some information cannot be confirmed. This page should not be used for official purposes.

FACP[edit | edit source]

The building is protected by a Simplex 4010 conventional fire alarm system. The panel is located in the main exit vestibule. This panel has Simplex 4090-9001 and 4090-9101 addressable monitor modules supervising all conventional zones. The system coding is temporal.

Notification Appliances[edit | edit source]

All notification appliances are Mirtone “Integrity” INT-5AT horn/strobes (red, wall-mount, 15cd).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are Mirtone 73353 conventional single-action pull stations.

Automatic Detection Devices[edit | edit source]

There are likely System Sensor C2W-BA conventional photoelectric smoke detectors in most areas.