Encore Tower, Edmonton: Difference between revisions

From FireAlarmPedia
(Notifier is good.)
 
No edit summary
 
(One intermediate revision by the same user not shown)
Line 5: Line 5:
|  
|  
|-
|-
| FACP: Notifier NFS2-3030C <br /> FACP Location: Unknown <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 70.7VRMS (Audible) <br> 24VDC (Visual) <br /> System Coding: Temporal <br> Strobes Synchronized: Yes, SS <br />Date of last known Upgrade: N/A <br />Year Opened: 2020
| FACP: Notifier NFS2-3030C <br /> FACP Location: Unknown <br />System Type: Single-Stage Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 70.7VRMS (Audible) <br> 24VDC (Visual) <br /> System Coding: Temporal <br> Strobes Synchronized: Yes, System Sensor <br />Date of last known Upgrade: N/A <br />Year Opened: 2020
|}
|}
 
'''Encore Tower''' is a condo tower located at 10180 103 Street Northwest, in Edmonton, Alberta, Canada. The building was built in 2020, and the fire alarm system is original.
'''Encore Tower''' is a condo tower located at 10180 103 Street Northwest, in Edmonton, Alberta, Canada. The building opened in 2020, and the fire alarm system is original.
 
==System Specifications==
==System Specifications==
====FACP====
====FACP====
The building is protected by a Notifier NFS2-3030C addressable fire alarm system. The panel location is unknown. The system runs Notifier’s FlashScan addressable protocol, and is equipped with Notifier’s “Digital Voice Command” voice evacuation system. The evacuation signal is a temporal tone, possibly followed by a message.
The building is protected by a Notifier NFS2-3030C addressable fire alarm system. The panel location is unknown. The system runs Notifier’s FlashScan addressable protocol, and is equipped with Notifier’s “Digital Voice Command” voice evacuation system. The evacuation signal is a temporal tone, possibly followed by a message.
 
=====Annunciators=====
=====Annunciators=====
There is a Notifier LCD-160 annunciator in the main entrance vestibule.
There is a Notifier LCD-160 annunciator in the main entrance vestibule.
====Notification Appliances====
====Notification Appliances====
All known notification appliances are System Sensor “L-Series” SPSWLA speaker/strobes (white, wall-mount, set to 70V/15cd).
All known notification appliances are System Sensor “L-Series” SPSWLA speaker/strobes (white, wall-mount, set to 70V/15cd).
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations are Notifier NBG-12LX addressable dual-action pull stations.
All pull stations are Notifier NBG-12LX addressable dual-action pull stations.
====Automatic Detection Devices====
====Automatic Detection Devices====
There are Notifier FSP-951A addressable photoelectric smoke detectors throughout the building, mounted on System Sensor B300A-6 low-profile bases. The building is equipped with a wet sprinkler system.
There are Notifier FSP-951A addressable photoelectric smoke detectors throughout the building, mounted on System Sensor B300A-6 low-profile bases. The building is equipped with a wet sprinkler system.
 
====Modules====
====Modules====
There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
There are Notifier FRM-1A addressable relay modules serving various purposes.
There are Notifier ISO-XA isolator modules on all SLCs.
==== EOLs ====
There are Notifier EOL-CR end of line resistor plates on all sprinkler and signal circuits.
[[Category:Edmonton]]
[[Category:Residential]]

Latest revision as of 18:55, 26 September 2024

System Specifications
FACP: Notifier NFS2-3030C
FACP Location: Unknown
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 70.7VRMS (Audible)
24VDC (Visual)
System Coding: Temporal
Strobes Synchronized: Yes, System Sensor
Date of last known Upgrade: N/A
Year Opened: 2020

Encore Tower is a condo tower located at 10180 103 Street Northwest, in Edmonton, Alberta, Canada. The building was built in 2020, and the fire alarm system is original.

System Specifications[edit | edit source]

FACP[edit | edit source]

The building is protected by a Notifier NFS2-3030C addressable fire alarm system. The panel location is unknown. The system runs Notifier’s FlashScan addressable protocol, and is equipped with Notifier’s “Digital Voice Command” voice evacuation system. The evacuation signal is a temporal tone, possibly followed by a message.

Annunciators[edit | edit source]

There is a Notifier LCD-160 annunciator in the main entrance vestibule.

Notification Appliances[edit | edit source]

All known notification appliances are System Sensor “L-Series” SPSWLA speaker/strobes (white, wall-mount, set to 70V/15cd).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are Notifier NBG-12LX addressable dual-action pull stations.

Automatic Detection Devices[edit | edit source]

There are Notifier FSP-951A addressable photoelectric smoke detectors throughout the building, mounted on System Sensor B300A-6 low-profile bases. The building is equipped with a wet sprinkler system.

Modules[edit | edit source]

There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system’s tamper and flow switches.

There are Notifier FRM-1A addressable relay modules serving various purposes.

There are Notifier ISO-XA isolator modules on all SLCs.

EOLs[edit | edit source]

There are Notifier EOL-CR end of line resistor plates on all sprinkler and signal circuits.