| FACP: Simplex 4010ES <br />FACP Location: Main Entrance Vestibule <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: | | FACP: Simplex 4010ES <br />FACP Location: Main Entrance Vestibule <br />System Type: Single-Stage Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br>Strobes Synchronized: Yes, SmartSync <br />Date of last known Upgrade: 2012? <br />Year Opened: 1990 | ||
|} | |} | ||
The '''Forest Lawn Radio Site''' is a radio tower located at 2774 2 Ave SE, Calgary, AB. It transmits the Calgary Municipal Radio Network. It was built in 1990, and the fire alarm system was upgraded around 2012. | The '''Forest Lawn Radio Site''' is a radio tower located at 2774 2 Ave SE, Calgary, AB. It transmits the Calgary Municipal Radio Network. It was built in 1990, and the fire alarm system was upgraded around 2012. | ||
== System Specifications (2012-present) == | == System Specifications (2012-present) == | ||
==== FACP ==== | ==== FACP ==== | ||
The building is protected by a Simplex 4010ES addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Simplex’s IDNet addressable protocol, and the system coding is temporal. | The building is protected by a Simplex 4010ES addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Simplex’s IDNet addressable protocol, and the system coding is temporal. | ||
==== Notification Appliances ==== | ==== Notification Appliances ==== | ||
All notification appliances are Simplex “TrueAlert” 4906-9127 horn/strobes (red, wall-mount, set to 15cd). <br> For outdoor notification, there is a Simplex 4906-9105 weatherproof remote strobe (red, wall-mount, set to 60cd). | All notification appliances are Simplex “TrueAlert” 4906-9127 horn/strobes (red, wall-mount, set to 15cd). <br> For outdoor notification, there is a Simplex 4906-9105 weatherproof remote strobe (red, wall-mount, set to 60cd). | ||
=== Initiating Devices === | === Initiating Devices === | ||
==== Pull Stations ==== | ==== Pull Stations ==== | ||
Most pull stations are Simplex 4099-9001 addressable single-action pull stations. <br> The server room has Simplex 4099-9003 addressable dual-action pull stations. | Most pull stations are Simplex 4099-9001 addressable single-action pull stations. <br> The server room has Simplex 4099-9003 addressable dual-action pull stations. | ||
==== Automatic Detection Devices ==== | ==== Automatic Detection Devices ==== | ||
There are Simplex 4098-9714 addressable photoelectric smoke detectors, mounted on 4098-9792 bases. | There are Simplex 4098-9714 addressable photoelectric smoke detectors, mounted on 4098-9792 bases. | ||
==== Modules ==== | ==== Modules ==== | ||
There is a Sapphire fire suppression system, connected via a Simplex 4090-9001 module. <br>There are also Simplex 4090-9002 addressable relay modules serving various purposes. | |||
There is a Sapphire fire suppression system, connected via a Simplex 4090-9001 module. <br> There are also Simplex 4090-9002 addressable relay modules serving various purposes. | [[Category:Calgary]] |
Latest revision as of 20:42, 27 September 2024
System Specifications |
---|
FACP: Simplex 4010ES FACP Location: Main Entrance Vestibule System Type: Single-Stage Addressable System Line Voltage: 120VAC NAC Voltage: 24VDC System Coding: Temporal Strobes Synchronized: Yes, SmartSync Date of last known Upgrade: 2012? Year Opened: 1990 |
The Forest Lawn Radio Site is a radio tower located at 2774 2 Ave SE, Calgary, AB. It transmits the Calgary Municipal Radio Network. It was built in 1990, and the fire alarm system was upgraded around 2012.
System Specifications (2012-present)[edit | edit source]
FACP[edit | edit source]
The building is protected by a Simplex 4010ES addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Simplex’s IDNet addressable protocol, and the system coding is temporal.
Notification Appliances[edit | edit source]
All notification appliances are Simplex “TrueAlert” 4906-9127 horn/strobes (red, wall-mount, set to 15cd).
For outdoor notification, there is a Simplex 4906-9105 weatherproof remote strobe (red, wall-mount, set to 60cd).
Initiating Devices[edit | edit source]
Pull Stations[edit | edit source]
Most pull stations are Simplex 4099-9001 addressable single-action pull stations.
The server room has Simplex 4099-9003 addressable dual-action pull stations.
Automatic Detection Devices[edit | edit source]
There are Simplex 4098-9714 addressable photoelectric smoke detectors, mounted on 4098-9792 bases.
Modules[edit | edit source]
There is a Sapphire fire suppression system, connected via a Simplex 4090-9001 module.
There are also Simplex 4090-9002 addressable relay modules serving various purposes.