| FACP: Edwards FireShield <br /> FACP Location: Main Entrance <br />System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br /> System Coding: Temporal <br />Date of last known Upgrade: 2010s <br />Year Opened: 1980
| FACP: EST FireShield FS1004G<br /> FACP Location: Main Entrance <br />System Type: Single-Stage Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br /> System Coding: Temporal <br />Date of last known Upgrade: 2010s <br />Year Opened: 1980
|}
|}
 
'''HealthPlus Midnapore''' is a multitenant medical building located at 290 Midpark Way Southeast, in Calgary, Alberta, Canada. The building opened in 1980, and the fire alarm system has been slowly upgraded over the years; only some pull stations and one bell remain original.
'''HealthPlus Midnapore''' is a multitenant medical building located at 290 Midpark Way Southeast, in Calgary, Alberta, Canada. The building opened in 1980, and the fire alarm system has been slowly upgraded over the years; only some pull stations and one bell remain original.
==System Specifications (1980-present)==
 
==System Specifications==
====FACP====
====FACP====
The building is protected by an Edwards FireShield FS1004G conventional fire alarm system. The panel is located in the main entrance vestibule. The system coding is temporal. This panel was installed in about 2007 replacing an Edwards 2280.
The building is protected by an EST FireShield FS1004G conventional fire alarm system. The panel is located in the main entrance vestibule. The system coding is temporal. This panel was installed circa 2004 replacing an Edwards 2280.
====Notification Appliances====
The notification appliances are a mix of Edwards 439D-10AWC vibrating bells (10” gong) and Mircom BL-10B motor bells (10” gong); the Mircom bells were deficiency replacements.  


====Notification Appliances====
The dental office has an Edwards “Durabel” 6100D vibrating bell (10” gong), the only original bell remaining.  
Most notification appliances are a mix of Edwards 439D-10AWC vibrating bells (10” gong) and Mircom BL-10B motor bells (10” gong).  The dental office has an Edwards “Durabel” 6100D vibrating bell (10” gong), the only original bell remaining.  The atrium has a Mircom BL-6B motor bell (6” gong).


The atrium has a Mircom BL-6B motor bell (6” gong) as a deficiency replacement.
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
Most pull stations are Edwards 270-SPO conventional single-action pull stations.  Some areas have Mircom MS-401 conventional single-action pull stations as deficiency replacements.
Most pull stations are Edwards 270-SPO conventional single-action pull stations.  


Some areas have Mircom MS-401 conventional single-action pull stations as deficiency replacements.
====Automatic Detection Devices====
====Automatic Detection Devices====
There are likely FDD CR-135 conventional 135°F fixed/rate-of-rise heat detectors present, however this is unconfirmed. The building is not equipped with a sprinkler system.
There are likely FDD CR-135 conventional 135°F fixed/rate-of-rise heat detectors present, however this is unconfirmed. The building is not equipped with a sprinkler system.
[[Category:Facilitie]
 
==== EOLs ====
There are Edwards EOL-P1 end-of-line resistor plates on all circuits.
[[Category:Calgary]]
[[Category:Healthcare]]

Latest revision as of 23:42, 29 September 2024

System Specifications
FACP: EST FireShield FS1004G
FACP Location: Main Entrance
System Type: Single-Stage Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Temporal
Date of last known Upgrade: 2010s
Year Opened: 1980

HealthPlus Midnapore is a multitenant medical building located at 290 Midpark Way Southeast, in Calgary, Alberta, Canada. The building opened in 1980, and the fire alarm system has been slowly upgraded over the years; only some pull stations and one bell remain original.

System Specifications (1980-present)[edit | edit source]

FACP[edit | edit source]

The building is protected by an EST FireShield FS1004G conventional fire alarm system. The panel is located in the main entrance vestibule. The system coding is temporal. This panel was installed circa 2004 replacing an Edwards 2280.

Notification Appliances[edit | edit source]

The notification appliances are a mix of Edwards 439D-10AWC vibrating bells (10” gong) and Mircom BL-10B motor bells (10” gong); the Mircom bells were deficiency replacements.

The dental office has an Edwards “Durabel” 6100D vibrating bell (10” gong), the only original bell remaining.

The atrium has a Mircom BL-6B motor bell (6” gong) as a deficiency replacement.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

Most pull stations are Edwards 270-SPO conventional single-action pull stations.

Some areas have Mircom MS-401 conventional single-action pull stations as deficiency replacements.

Automatic Detection Devices[edit | edit source]

There are likely FDD CR-135 conventional 135°F fixed/rate-of-rise heat detectors present, however this is unconfirmed. The building is not equipped with a sprinkler system.

EOLs[edit | edit source]

There are Edwards EOL-P1 end-of-line resistor plates on all circuits.