Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

Mail is now working! Feel free to request an account. Accounts are available to invested enthusiasts/technicians in the industry. :)

Hoff Elementary School: Difference between revisions

From FireAlarmPedia
mNo edit summary
 
(One intermediate revision by the same user not shown)
Line 3: Line 3:
!System Specifications
!System Specifications
|-
|-
|FACP: Simplex 4010 <br />
|FACP: Simplex 4010 <br />FACP Location: Unknown <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br />Strobes Synchronized Yes, SmartSync<br>Date of last known Upgrade: N/A <br />Year Opened: 2001
FACP Location: Unknown <br />
System Type: Addressable <br />
System Line Voltage: 120VAC<br />
NAC Voltage: 24VDC <br />
System Coding: Temporal 3 <br />
Strobes Synchronized Yes, SmartSync<br>
Date of last known Upgrade: N/A <br />
Year Opened: 2001
|}
|}
'''Hoff Elementary School''' is a Elementary School within the Weld County School School District 3J, This School is located in 7558 WCR 59, Keenesburg, Colorado. The school opened for the 2002-03 school year, and the fire alarm system is original.
'''Hoff Elementary School''' is a Elementary School within the Weld County School School District 3J, This School is located in 7558 WCR 59, Keenesburg, Colorado. The school opened for the 2002-03 school year, and the fire alarm system is original.
Line 18: Line 10:
==System Specifications==
==System Specifications==
===FACP===
===FACP===
The building is protected by a Simplex 4010 fire alarm system. The panel location is unknown. The system runs IDNet addressable protocol, and the system coding is Temporal 3.
The building is protected by a Simplex 4010 fire alarm system. The panel location is unknown. The system runs Simplex's IDNet addressable protocol, and the system coding is Temporal.
====Notification Appliances====
====Notification Appliances====
All notification appliances are Simplex "TrueAlert" 4903-9417 Horn Strobes (Red, Wall-Mount, 15cd).
All notification appliances are Simplex "TrueAlert" 4903-9417 Horn Strobes (Red, Wall-Mount, 15cd).

Latest revision as of 10:52, 30 September 2024

System Specifications
FACP: Simplex 4010
FACP Location: Unknown
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized Yes, SmartSync
Date of last known Upgrade: N/A
Year Opened: 2001

Hoff Elementary School is a Elementary School within the Weld County School School District 3J, This School is located in 7558 WCR 59, Keenesburg, Colorado. The school opened for the 2002-03 school year, and the fire alarm system is original.

Note: This page is sourced from The Fire Panel Forums.

System Specifications

FACP

The building is protected by a Simplex 4010 fire alarm system. The panel location is unknown. The system runs Simplex's IDNet addressable protocol, and the system coding is Temporal.

Notification Appliances

All notification appliances are Simplex "TrueAlert" 4903-9417 Horn Strobes (Red, Wall-Mount, 15cd).

Some rooms have Simplex "TrueAlert" 4904-9331 Strobes (Red, Wall-Mount, 15cd).

The outdoor devices are Wheelock MT-24-WM Weatherproof Horn Strobe (Red, Wall-Mount, 177cd, set to horn) with a System Sensor "SpectrAlert Advance" P2RK Weatherproof Horn Strobe (Red, Wall-Mount, set on 75cd) as a deficiency replacement.

Initiating Devices

Pull Stations

No pull stations noticed.

Automatic Detection Devices

All Smoke Detectors are Simplex "TrueAlarm" 4098-9714 Addressable Photoelectric Smoke Detectors, mounted on Simplex 4098-9792 bases.