More actions
(BRBNST) |
No edit summary |
||
(2 intermediate revisions by 2 users not shown) | |||
Line 5: | Line 5: | ||
| | | | ||
|- | |- | ||
| FACP: Simplex 4007ES <br />FACP Location: | | FACP: Simplex 4007ES <br />FACP Location: Main Entrance Vestibule <br />System Type: Single-Stage Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br>Strobes Synchronized: Yes, SmartSync <br />Date of last known Upgrade: N/A <br />Year Opened: 2020 | ||
|} | |} | ||
'''Japanese Village''' is a Japanese restaurant located at 1638 BRBN ST, West Edmonton Mall, at 8882 170 St NW, Edmonton, AB. It opened in 2020 and the fire alarm system is original. | '''Japanese Village''' is a Japanese restaurant located at 1638 BRBN ST, West Edmonton Mall, at 8882 170 St NW, Edmonton, AB. It opened in 2020 and the fire alarm system is original. | ||
== System Specifications (2020-present) == | == System Specifications (2020-present) == | ||
Note: This system does not supervise Mai Vietnamese Fusion despite being next to each other and having the same devices. | Note: This system does not supervise Mai Vietnamese Fusion despite being next to each other and having the same devices. | ||
==== FACP ==== | ==== FACP ==== | ||
The restaurant is protected by a Simplex 4007ES addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Simplex’s IDNet addressable protocol, and the system coding is temporal. | |||
The restaurant is protected by a Simplex 4007ES addressable fire alarm system. The panel is located in the main entrance. The system runs Simplex’s IDNet addressable protocol, and the system coding is temporal. | |||
==== Notification Appliances ==== | ==== Notification Appliances ==== | ||
All notification appliances are Simplex “TrueAlert” 4906-9127 horn/strobes (red, wall-mount, set to 15cd). | All notification appliances are Simplex “TrueAlert” 4906-9127 horn/strobes (red, wall-mount, set to 15cd). | ||
=== Initiating Devices === | === Initiating Devices === | ||
==== Pull Stations ==== | ==== Pull Stations ==== | ||
All pull stations are Simplex 4099-9004 addressable single-action pull stations. | All pull stations are Simplex 4099-9004 addressable single-action pull stations. | ||
==== Automatic Detection Devices ==== | ==== Automatic Detection Devices ==== | ||
None noticed. | |||
==== Modules ==== | ==== Modules ==== | ||
There are Simplex 4090-9001 addressable monitor modules supervising the sprinkler system’s tamper and flow switches. | |||
There are Simplex | ==== EOLs ==== | ||
There are Simplex 2081-9040C end of line resistor plates on all sprinkler and signal circuits. | |||
[[Category:Edmonton]] | |||
[[Category:Restaurants]] |
Latest revision as of 11:43, 30 September 2024
System Specifications |
---|
FACP: Simplex 4007ES FACP Location: Main Entrance Vestibule System Type: Single-Stage Addressable System Line Voltage: 120VAC NAC Voltage: 24VDC System Coding: Temporal Strobes Synchronized: Yes, SmartSync Date of last known Upgrade: N/A Year Opened: 2020 |
Japanese Village is a Japanese restaurant located at 1638 BRBN ST, West Edmonton Mall, at 8882 170 St NW, Edmonton, AB. It opened in 2020 and the fire alarm system is original.
System Specifications (2020-present)[edit | edit source]
Note: This system does not supervise Mai Vietnamese Fusion despite being next to each other and having the same devices.
FACP[edit | edit source]
The restaurant is protected by a Simplex 4007ES addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Simplex’s IDNet addressable protocol, and the system coding is temporal.
Notification Appliances[edit | edit source]
All notification appliances are Simplex “TrueAlert” 4906-9127 horn/strobes (red, wall-mount, set to 15cd).
Initiating Devices[edit | edit source]
Pull Stations[edit | edit source]
All pull stations are Simplex 4099-9004 addressable single-action pull stations.
Automatic Detection Devices[edit | edit source]
None noticed.
Modules[edit | edit source]
There are Simplex 4090-9001 addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
EOLs[edit | edit source]
There are Simplex 2081-9040C end of line resistor plates on all sprinkler and signal circuits.