| FACP: Notifier NFS-320C <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />Date of last known Upgrade: 2010s <br />Year Opened: 2005
| FACP: Notifier NFS-320C <br /> FACP Location: Unconfirmed<br />System Type: Single-Stage Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br /> System Coding: Temporal <br /> Strobes Synchronized: Yes<br />Date of last known Upgrade: 2010s <br />Year Opened: 2005
|}
|}
 
'''Real Canadian Superstore''' is a chain of supermarkets owned by Loblaws. This particular store is located at Unit 100 3633 Westwinds Dr NE in the Westwinds neighborhood of Northeast Calgary. The store opened in 2005, and had its system replaced in the 2010s.
'''Real Canadian Superstore''' is a chain of supermarkets owned by Loblaws. This particular store is located in the Westwinds neighborhood of Northeast Calgary. The store opened in 2005, and had its system replaced in the 2010s.
==System Specifications (2010s-present)==
 
==System Specifications==
====FACP====
====FACP====
The store is protected by a Notifier NFS-320C addressable fire alarm system. The panel is likely located in one entrance, but this is unconfirmed. The system runs Notifier’s FlashScan addressable protocol, and does code 3 in alarm.
The store is protected by a Notifier NFS-320C addressable fire alarm system. The panel is likely located in one entrance, but this is unconfirmed. The system runs Notifier’s FlashScan addressable protocol, and the system coding is temporal.
 
=====Annunciators=====
=====Annunciators=====
There are two annunciator modules at the south entrance. One is a Notifier LCD2-80 annunciator, and the other is a Notifier ACM-24AT 24-LED annunciator.
There are two annunciator modules at the south entrance. One is a Notifier LCD2-80 annunciator, and the other is a Notifier ACM-24AT 24-LED annunciator.
 
====Notification Appliances====
====Notification Appliances====
All notification appliances are System Sensor “SpectrAlert Advance” P2RA horn/strobes (red, wall-mount).
All notification appliances are System Sensor “SpectrAlert Advance” P2RA horn/strobes (red, wall-mount).
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations are Notifier N-MPS-SA addressable single-action pull stations.
All pull stations are Notifier N-MPS-SA addressable single-action pull stations.
====Automatic Detection Devices====
There may be some smoke detectors, although this is unconfirmed. There is also a sprinkler system with waterflow detection.
==== Modules ====
There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system's flow and tamper switches.


====Automatic Detection Devices====
==== EOLs ====
There may be some smoke detectors, although this is unconfirmed.
There are Notifier EOL-CR end-of-line resistor plates on all sprinkler and signal circuits.


==System Specifications (2005-2010s)==
==System Specifications (2005-2010s)==
Line 34: Line 33:
|  
|  
|-
|-
| FACP: EST QuickStart QS1 <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />Date of last known Upgrade: N/A <br />Final Year in Service: 2010s
| FACP: EST QuickStart QS1
FACP Location: Main Entrance<br />System Type: Single-Stage Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR  
 
System Coding: Temporal
 
Strobes Synchronized: Yes<br />Date of last known Upgrade: N/A <br />Final Year in Service: 2010s
|}
|}
Please note that this is purely speculation, and is based off the previous system at the Deerfoot Meadows location.
Please note that this is purely speculation, and is based off the previous system at the Deerfoot Meadows location.
====FACP====
====FACP====
The store was protected by an EST QuickStart QS1 addressable fire alarm system. The panel was located in one entrance. The system ran EST’s Signature-series addressable protocol, and did code 3 in alarm.
The store was protected by an EST QuickStart QS1 addressable fire alarm system. The panel was located in one entrance. The system ran EST’s Signature addressable protocol, and the system coding was temporal.
 
====Notification Appliances====
====Notification Appliances====
All notification appliances were EST “Genesis” G1R-HDVM horn/strobes (red, wall-mount).
All notification appliances were EST “Genesis” G1R-HDVM horn/strobes (red, wall-mount).
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations were EST SIGA-270 addressable single-action pull stations.
All pull stations were EST SIGA-270 addressable single-action pull stations.
====Automatic Detection Devices====
Not known. There was a sprinkler system with waterflow detection.
==== Modules ====
There were EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's flow and tamper switches.


====Automatic Detection Devices====
==== EOLs ====
Not known.
There were Edwards EOL-P1 end-of-line resistor plates on all sprinkler and signal circuits.
[[Category:Facilities]]
[[Category:Calgary]]
[[Category:Retail Stores]]

Latest revision as of 22:06, 11 October 2024

System Specifications
FACP: Notifier NFS-320C
FACP Location: Unconfirmed
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: Yes
Date of last known Upgrade: 2010s
Year Opened: 2005

Real Canadian Superstore is a chain of supermarkets owned by Loblaws. This particular store is located at Unit 100 3633 Westwinds Dr NE in the Westwinds neighborhood of Northeast Calgary. The store opened in 2005, and had its system replaced in the 2010s.

System Specifications (2010s-present)[edit | edit source]

FACP[edit | edit source]

The store is protected by a Notifier NFS-320C addressable fire alarm system. The panel is likely located in one entrance, but this is unconfirmed. The system runs Notifier’s FlashScan addressable protocol, and the system coding is temporal.

Annunciators[edit | edit source]

There are two annunciator modules at the south entrance. One is a Notifier LCD2-80 annunciator, and the other is a Notifier ACM-24AT 24-LED annunciator.

Notification Appliances[edit | edit source]

All notification appliances are System Sensor “SpectrAlert Advance” P2RA horn/strobes (red, wall-mount).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are Notifier N-MPS-SA addressable single-action pull stations.

Automatic Detection Devices[edit | edit source]

There may be some smoke detectors, although this is unconfirmed. There is also a sprinkler system with waterflow detection.

Modules[edit | edit source]

There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system's flow and tamper switches.

EOLs[edit | edit source]

There are Notifier EOL-CR end-of-line resistor plates on all sprinkler and signal circuits.

System Specifications (2005-2010s)[edit | edit source]

System Specifications
FACP: EST QuickStart QS1

FACP Location: Main Entrance
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR

System Coding: Temporal

Strobes Synchronized: Yes
Date of last known Upgrade: N/A
Final Year in Service: 2010s

Please note that this is purely speculation, and is based off the previous system at the Deerfoot Meadows location.

FACP[edit | edit source]

The store was protected by an EST QuickStart QS1 addressable fire alarm system. The panel was located in one entrance. The system ran EST’s Signature addressable protocol, and the system coding was temporal.

Notification Appliances[edit | edit source]

All notification appliances were EST “Genesis” G1R-HDVM horn/strobes (red, wall-mount).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations were EST SIGA-270 addressable single-action pull stations.

Automatic Detection Devices[edit | edit source]

Not known. There was a sprinkler system with waterflow detection.

Modules[edit | edit source]

There were EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's flow and tamper switches.

EOLs[edit | edit source]

There were Edwards EOL-P1 end-of-line resistor plates on all sprinkler and signal circuits.