| FACP: Notifier NFS-320C
| FACP: Notifier NFS-320C
FACP Location: Main Entrance Vestibule<br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC  
FACP Location: Main Entrance Vestibule<br />System Type: Single-Stage Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC  


System Coding: Temporal
System Coding: Temporal


Strobes Synchronized: Yes<br />Date of last known Upgrade: N/A <br />Year Opened: 2012
Strobes Synchronized: Yes, SS<br />Date of last known Upgrade: N/A <br />Year Opened: 2012
|}
|}
'''Royal Vista Professional Building''' is a 3-story mixed-use building in Royal Vista, NW Calgary. It was built in 2012, and has its original fire alarm system. There are many tenants on the ground floor, they include Mad Rose Pub, My Gym Children's Fitness Centre, etc. It is also an office building on the two floors above.  
'''Royal Vista Professional Building''' is a 3-story mixed-use building located at 15 Royal Vista Place NW, Calgary, AB. It was built in 2012, and has its original fire alarm system. There are many tenants on the ground floor, they include Mad Rose Pub, My Gym Children's Fitness Centre, etc. It is also an office building on the two floors above.  
== System Specifications ==
== System Specifications (2012-present) ==
==== FACP ====
==== FACP ====
The building is protected by a Notifier NFS-320C addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Notifier's FlashScan addressable protocol, and the system coding is temporal.  
The building is protected by a Notifier NFS-320C addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Notifier's FlashScan addressable protocol, and the system coding is temporal.  
==== Notification Appliances ====
==== Notification Appliances ====
All of the notification appliances are from System Sensor's "SpectrAlert Advance" line of products. The notification appliances in the tenants and on the ground floor are System Sensor P2RA (red, wall-mount) horn/strobe. The upper floors have System Sensor PC2WA (white, ceiling-mount) horn/strobes on the wall or ceiling. It is unknown why they installed some PC2WA horn/strobes on the walls, likely a supply issue. There is a System Sensor SRKA (red, wall-mount) weatherproof remote strobe outside the main entrance.
All of the notification appliances are from System Sensor's "SpectrAlert Advance" line of products.  
 
The notification appliances in the tenants and on the ground floor are System Sensor P2RA (red, wall-mount) horn/strobe.  
 
The upper floors have System Sensor PC2WA (white, ceiling-mount) horn/strobes on the wall or ceiling. It is unknown why they installed some PC2WA horn/strobes on the walls, likely a supply issue.  
 
There is a System Sensor SRKA (red, wall-mount) weatherproof remote strobe outside the main entrance.
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
The main pull stations are Notifier N-MPS-SA bilingual, addressable pull stations.
All pull stations are Notifier N-MPS-SA bilingual addressable single-action pull stations.
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
There are Notifier FSP-851A addressable photoelectric smoke detectors on the 2nd floor, mounted on B210LPA bases. There is also additional protection by waterflow.
There are Notifier FSP-851A addressable photoelectric smoke detectors on the 2nd floor, mounted on B210LPA bases. There is also additional protection by waterflow.
==== Modules ====
There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system's tamper and flow switches.
==== EOLs ====
There are Notifier EOL-CR end-of-line resistor plates on all sprinkler and signal circuits.
[[Category:Facilities]]
[[Category:Calgary]]
[[Category:Restaurants]]
[[Category:Commercial]]

Latest revision as of 23:26, 11 October 2024

System Specifications
FACP: Notifier NFS-320C

FACP Location: Main Entrance Vestibule
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC

System Coding: Temporal

Strobes Synchronized: Yes, SS
Date of last known Upgrade: N/A
Year Opened: 2012

Royal Vista Professional Building is a 3-story mixed-use building located at 15 Royal Vista Place NW, Calgary, AB. It was built in 2012, and has its original fire alarm system. There are many tenants on the ground floor, they include Mad Rose Pub, My Gym Children's Fitness Centre, etc. It is also an office building on the two floors above.

System Specifications (2012-present)[edit | edit source]

FACP[edit | edit source]

The building is protected by a Notifier NFS-320C addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Notifier's FlashScan addressable protocol, and the system coding is temporal.

Notification Appliances[edit | edit source]

All of the notification appliances are from System Sensor's "SpectrAlert Advance" line of products.

The notification appliances in the tenants and on the ground floor are System Sensor P2RA (red, wall-mount) horn/strobe.

The upper floors have System Sensor PC2WA (white, ceiling-mount) horn/strobes on the wall or ceiling. It is unknown why they installed some PC2WA horn/strobes on the walls, likely a supply issue.

There is a System Sensor SRKA (red, wall-mount) weatherproof remote strobe outside the main entrance.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are Notifier N-MPS-SA bilingual addressable single-action pull stations.

Automatic Detection Devices[edit | edit source]

There are Notifier FSP-851A addressable photoelectric smoke detectors on the 2nd floor, mounted on B210LPA bases. There is also additional protection by waterflow.

Modules[edit | edit source]

There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system's tamper and flow switches.

EOLs[edit | edit source]

There are Notifier EOL-CR end-of-line resistor plates on all sprinkler and signal circuits.