Safeway (Dalhousie): Difference between revisions

From FireAlarmPedia
(Well, the 6632 is no more after 25 years of service. A moment of silence for the now-gone system. Typical Simplex 4007ES Safeway system. XD)
No edit summary
 
(10 intermediate revisions by 3 users not shown)
Line 5: Line 5:
|  
|  
|-
|-
| FACP: Simplex 4007ES <br />System Type: Hybrid <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />Date of last known Upgrade: 2021 <br />Year Opened: 1996
| FACP: Simplex 4007ES <br /> FACP Location: Main Entrance Vestibule <br />System Type: Single-Stage Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br /> System Coding: Temporal <br> Strobes Synchronized: Yes, SmartSync<br />Date of last known Upgrade: 2021 <br />Year Opened: 1996
|}
|}
'''Safeway Canada''' is a Canadian grocery store chain owned by Sobeys. This particular store is located at 5005 Dalhousie Drive Northwest #100, in Calgary, Alberta, Canada. The store opened in 1996, and the fire alarm system is from 2021.
==System Specifications (2021-present)==
Please note that some system information is unconfirmed. This page should not be used for official purposes.
====FACP====
The building is protected by a Simplex 4007ES conventional fire alarm system. The panel is located in the main entrance vestibule. The system coding is temporal.
====Notification Appliances====
All notification appliances are from Simplex's "TrueAlert" line of products. Most notification appliances are Simplex “TrueAlert” 4906-9127 horn/strobes (red, wall-mount, set to 15cd). There are Simplex 4906-9104 remote strobes (white, ceiling-mount, set to 30cd) located throughout the store on the ceiling.


'''Safeway''' is a chain of grocery stores in Alberta. This particular location is in Dalhousie, NW Calgary. It is officially called Safeway Dalhousie Station, due to being adjacent to the Dalhousie station on the CTrain line. It was built in 1996, and the fire alarm system was recently replaced, and only a few pull stations remain. The store is in a large plaza, however only the Safeway is protected by a fire alarm system.
There is a Simplex 4906-9105 weatherproof remote strobe (red, wall-mount) outside the building.
===Initiating Devices===
====Pull Stations====
All storefront pull stations are Simplex 2099-9754 conventional single-action pull stations. The backroom has Edwards 270-SPO conventional single-action pull stations, leftover from the old system.
====Automatic Detection Devices====
The store is equipped with a sprinkler system, and no detectors are present in the storefront.


== System Specifications ==
==== EOLs ====
There are Simplex 2081-9040C end-of-line resistor plates on all circuits.


==== FACP ====
==System Specifications (1996-2021)==
 
The fire alarm panel is a Simplex 4007ES, specifically 4007-9202 (Platinum cabinet). It is located in the entrance on the right. It replaced the original EST 6632 in 2021 most likely due to a CPU failure, and because the 6632 was large, there is drywall covering the 6632's space. The permit issued for this upgrade was "Fire Alarm System Modification - Replace Fire Alarm Panel and select initiating/signaling devices." on February 12, 2021.
 
==== Notification Appliances ====
 
The notification appliances are all from Simplex's "TrueAlert" lineup. The store has Simplex 4906-9127 (red, wall-mount, SmartSync) horn/strobes installed in the original bell/strobes places, leaving the area not covered by the horn/strobe unpainted. On the ceilings, there are Simplex 4906-9104 (white, ceiling-mount, SmartSync) remote strobes, installed in place of the previous strobes. Outside the entrance, there is a Simplex 4906-9131 (red, wall-mount, SmartSync) weatherproof remote strobe.
 
=== Initiating Devices ===
 
==== Pull Stations ====
 
The pull stations are still mostly the original Edwards 270-SPO pull stations, but there is one Simplex 2099-9754 at the entrance, installed during the upgrade.
 
==== Automatic Detection Devices ====
 
None noticed.
 
== Former System Specifications ==
{| style="float:right;border:2px solid black"
{| style="float:right;border:2px solid black"
|-
|-
! System Specifications
!Former System Specifications
|-
|-
|  
|
|-
|-
| FACP: EST 6632 <br />System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />Date of last known Upgrade: Early 2010s <br />Year Decommissioned: 2021
|FACP: EST 6632<br /> FACP Location: Main Entrance Vestibule <br />System Type: Single-Stage Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR<br /> System Coding: Continuous<br> Strobes Synchronized: No<br />Date of last known Upgrade: 2010s<br />Year Decomissioned: 2021
|}
|}
==== FACP ====
====FACP====
 
The building was protected by an EST 6632 conventional fire alarm system. The panel was located in the main entrance vestibule. The system coding was continuous. The panel was replaced due to a main board failure.
The fire alarm control panel was an EST 6632. It was original and was located in the entrance on the right. In 2021, it was replaced with a Simplex 4007ES.  
====Notification Appliances====
 
Most notification appliances were Edwards 439D-10AWC vibrating bells (10” gong), mounted on Edwards 403-5A-001 strobe plates (15cd). There was one Wheelock RSSP-24MCW strobe plate in the floral department as a deficiency replacement; the Edwards bell remained intact. The centre areas of the store had Edwards 202-5A-001 remote strobes (red, wall-mount, 15cd) and Edwards 202-5A-101 remote strobes (white, wall-mount, 15cd) on the ceiling. There were also System Sensor “SpectrAlert Advance” SRA (red, wall-mount, set to 15cd) remote strobes on the ceiling, as deficiency replacements.  
==== Notification Appliances ====
 
The notification appliances mainly consisted of the original Edwards 439D-10AWC vibrating bells on EST "Integrity" 403-5A-R strobe plates. In the floral section, there was an Edwards 439D-10AWC bell on a Wheelock RSSP-24MCW strobe plate, the Wheelock strobe plate replaced an EST strobe plate that stopped working. On the ceiling, there was a mix of EST "Integrity" 202-5A-T (red) and 202-5A-TW (white) remote strobes scattered around, all with the standard wall "FIRE" lenses. They were original, and they are for additional visual coverage. Some of them had been replaced with System Sensor "SpectrAlert Advance" SR (red, wall) remote strobes, again on the ceiling. For outdoor notification, the  there was an Edwards 439D-10AWC vibrating bell on an EST 403-5A-R strobe plate at the entrance.
 
=== Initiating Devices ===
 
==== Pull Stations ====
 
The pull stations were all the original Edwards 270-SPO. Some are still installed.


==== Automatic Detection Devices ====
For exterior notification, there was an Edwards 439D-10AWC bell on EST 403-5A-001 strobe plate outside the entrance.
===Initiating Devices===
====Pull Stations====
All pull stations were Edwards 270-SPO conventional single-action pull stations.
====Automatic Detection Devices====
Not known. There was a sprinkler system with waterflow detection, wired as a zone on the 6632.


None noticed.
==== EOLs ====
There were Edwards EOL-P1 end-of-line resistor plates on all circuits.
[[Category:Facilities]]
[[Category:Calgary]]
[[Category:Retail Stores]]

Latest revision as of 23:31, 11 October 2024

System Specifications
FACP: Simplex 4007ES
FACP Location: Main Entrance Vestibule
System Type: Single-Stage Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: Yes, SmartSync
Date of last known Upgrade: 2021
Year Opened: 1996

Safeway Canada is a Canadian grocery store chain owned by Sobeys. This particular store is located at 5005 Dalhousie Drive Northwest #100, in Calgary, Alberta, Canada. The store opened in 1996, and the fire alarm system is from 2021.

System Specifications (2021-present)[edit | edit source]

Please note that some system information is unconfirmed. This page should not be used for official purposes.

FACP[edit | edit source]

The building is protected by a Simplex 4007ES conventional fire alarm system. The panel is located in the main entrance vestibule. The system coding is temporal.

Notification Appliances[edit | edit source]

All notification appliances are from Simplex's "TrueAlert" line of products. Most notification appliances are Simplex “TrueAlert” 4906-9127 horn/strobes (red, wall-mount, set to 15cd). There are Simplex 4906-9104 remote strobes (white, ceiling-mount, set to 30cd) located throughout the store on the ceiling.

There is a Simplex 4906-9105 weatherproof remote strobe (red, wall-mount) outside the building.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All storefront pull stations are Simplex 2099-9754 conventional single-action pull stations. The backroom has Edwards 270-SPO conventional single-action pull stations, leftover from the old system.

Automatic Detection Devices[edit | edit source]

The store is equipped with a sprinkler system, and no detectors are present in the storefront.

EOLs[edit | edit source]

There are Simplex 2081-9040C end-of-line resistor plates on all circuits.

System Specifications (1996-2021)[edit | edit source]

Former System Specifications
FACP: EST 6632
FACP Location: Main Entrance Vestibule
System Type: Single-Stage Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Continuous
Strobes Synchronized: No
Date of last known Upgrade: 2010s
Year Decomissioned: 2021

FACP[edit | edit source]

The building was protected by an EST 6632 conventional fire alarm system. The panel was located in the main entrance vestibule. The system coding was continuous. The panel was replaced due to a main board failure.

Notification Appliances[edit | edit source]

Most notification appliances were Edwards 439D-10AWC vibrating bells (10” gong), mounted on Edwards 403-5A-001 strobe plates (15cd). There was one Wheelock RSSP-24MCW strobe plate in the floral department as a deficiency replacement; the Edwards bell remained intact. The centre areas of the store had Edwards 202-5A-001 remote strobes (red, wall-mount, 15cd) and Edwards 202-5A-101 remote strobes (white, wall-mount, 15cd) on the ceiling. There were also System Sensor “SpectrAlert Advance” SRA (red, wall-mount, set to 15cd) remote strobes on the ceiling, as deficiency replacements.

For exterior notification, there was an Edwards 439D-10AWC bell on EST 403-5A-001 strobe plate outside the entrance.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations were Edwards 270-SPO conventional single-action pull stations.

Automatic Detection Devices[edit | edit source]

Not known. There was a sprinkler system with waterflow detection, wired as a zone on the 6632.

EOLs[edit | edit source]

There were Edwards EOL-P1 end-of-line resistor plates on all circuits.