More actions
mNo edit summary |
No edit summary |
||
(6 intermediate revisions by 3 users not shown) | |||
Line 5: | Line 5: | ||
| | | | ||
|- | |- | ||
| FACP: EST3X<br />System Type:Addressable<br /> System Line Voltage: 120VAC<br />NAC Voltage:24VDC <br />Date of last known Upgrade: | | FACP: Edwards EST3X <br /> FACP Location: Main Lobby by Escalators <br />System Type: Two-Stage Addressable<br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br /> System Coding: 20BPM (Alert)<br> Temporal (Alarm)<br> Strobes Synchronized: Yes <br />Date of last known Upgrade: 2017 <br />Year Opened: 2001 | ||
|} | |} | ||
'''Scotiabank Theatre | '''Scotiabank Theatre''' is a theatre chain owned by Cineplex. This particular theatre is located at 6455 Macleod Trail Southwest, in Calgary, Alberta, Canada. The theatre is attached to [[CF Chinook Centre]], however the fire alarm systems are not connected. The theatre opened in 2001, following the large expansion and renovation of the mall. The fire alarm system is original with the exception of the FACP and smoke detectors. | ||
==System Specifications== | |||
====FACP==== | |||
The building is protected by an Edwards EST3X addressable fire alarm system. The panel is located in the main lobby, to the left of the escalators. The system runs EST’s Signature addressable protocol, and is configured for two-stage operation. The alert signal coding is 20BPM, followed by temporal in for the alarm coding. This panel replaced an Edwards EST3, of which the cabinet remains, and is used as a junction box. | |||
=====Annunciators===== | |||
There is an Edwards EST3-LCDANN annunciator near the west entrance. | |||
====Notification Appliances==== | |||
All notification appliances are Edwards 439D-10AWC vibrating bells (10” gong) on EST 403-5A-R strobe plates (15cd). | |||
===Initiating Devices=== | |||
====Pull Stations==== | |||
All pull stations are EST SIGA-270P addressable two-stage single-action pull stations. | |||
====Automatic Detection Devices==== | |||
There are Edwards SIGA-PD addressable photoelectric smoke detectors throughout the building, mounted on SIGA-SB bases. | |||
==== Modules ==== | |||
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches. There are also EST SIGA-CR addressable relays serving various purposes. | |||
== | ==== EOLs ==== | ||
There are Edwards EOL-P1 end-of-line resistor plates on all sprinkler and signal circuits. | |||
[[Category:Facilities]] | |||
[[Category:Calgary]] | |||
[[Category:Movie Theatres]] | |||
Latest revision as of 21:02, 12 October 2024
System Specifications |
---|
FACP: Edwards EST3X FACP Location: Main Lobby by Escalators System Type: Two-Stage Addressable System Line Voltage: 120VAC NAC Voltage: 24VDC System Coding: 20BPM (Alert) Temporal (Alarm) Strobes Synchronized: Yes Date of last known Upgrade: 2017 Year Opened: 2001 |
Scotiabank Theatre is a theatre chain owned by Cineplex. This particular theatre is located at 6455 Macleod Trail Southwest, in Calgary, Alberta, Canada. The theatre is attached to CF Chinook Centre, however the fire alarm systems are not connected. The theatre opened in 2001, following the large expansion and renovation of the mall. The fire alarm system is original with the exception of the FACP and smoke detectors.
System Specifications[edit | edit source]
FACP[edit | edit source]
The building is protected by an Edwards EST3X addressable fire alarm system. The panel is located in the main lobby, to the left of the escalators. The system runs EST’s Signature addressable protocol, and is configured for two-stage operation. The alert signal coding is 20BPM, followed by temporal in for the alarm coding. This panel replaced an Edwards EST3, of which the cabinet remains, and is used as a junction box.
Annunciators[edit | edit source]
There is an Edwards EST3-LCDANN annunciator near the west entrance.
Notification Appliances[edit | edit source]
All notification appliances are Edwards 439D-10AWC vibrating bells (10” gong) on EST 403-5A-R strobe plates (15cd).
Initiating Devices[edit | edit source]
Pull Stations[edit | edit source]
All pull stations are EST SIGA-270P addressable two-stage single-action pull stations.
Automatic Detection Devices[edit | edit source]
There are Edwards SIGA-PD addressable photoelectric smoke detectors throughout the building, mounted on SIGA-SB bases.
Modules[edit | edit source]
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches. There are also EST SIGA-CR addressable relays serving various purposes.
EOLs[edit | edit source]
There are Edwards EOL-P1 end-of-line resistor plates on all sprinkler and signal circuits.