Line 5: Line 5:
|  
|  
|-
|-
| FACP: Notifier NFS-320C <br /> FACP Location: Unknown <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br /> System Coding: Temporal <br> Strobes Synchronized: Yes, SS <br />Date of last known Upgrade: N/A <br />Year Opened: 2014
| FACP: Notifier NFS-320C <br />FACP Location: Unknown <br />System Type: Single-Stage Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br>Strobes Synchronized: Yes, System Sensor <br />Date of last known Upgrade: N/A <br />Year Opened: 2014
|}
|}


 
'''Michaels''' is a North American chain of arts and crafts stores. This particular store is located at 2771 Main Street SW, in Airdrie, Alberta, Canada. The store was built in 2014, and the fire alarm system is original.
'''Michaels''' is a North American chain of arts and crafts stores. This particular store is located at 2771 Main Street Southwest, in Airdrie, Alberta, Canada. The store opened in 2014, and the fire alarm system is original.
==System Specifications==
==System Specifications==
====FACP====
====FACP====
Line 21: Line 20:
All pull stations are Notifier NBG-12LX addressable dual-action pull stations.
All pull stations are Notifier NBG-12LX addressable dual-action pull stations.
====Automatic Detection Devices====
====Automatic Detection Devices====
There is a Notifier FSP-851A addressable photoelectric smoke detector in the electrical room, mounted on a System Sensor B210LPA low-profile base. There are System Sensor DNRA duct smoke detectors with Notifier FSP-851A addressable photoelectric heads on all air handling units.
There is a Notifier FSP-851A addressable photoelectric smoke detector in the electrical room, mounted on a System Sensor B210LPA base.  
 
There are System Sensor DNRA duct smoke detector housings with Notifier FSP-851A addressable photoelectric heads on all air handling units.
 
==== Modules ====
There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system's tamper and flow switches.
 
There are Notifier FRM-1A addressable relay modules serving various purposes.
 
==== EOLs ====
There are Notifier EOL-CR end of line resistor plates on all sprinkler and signal circuits.
[[Category:Alberta]]
[[Category:Alberta]]
[[Category:Retail Stores]]
[[Category:Retail Stores]]

Latest revision as of 22:15, 12 October 2024

System Specifications
FACP: Notifier NFS-320C
FACP Location: Unknown
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: Yes, System Sensor
Date of last known Upgrade: N/A
Year Opened: 2014

Michaels is a North American chain of arts and crafts stores. This particular store is located at 2771 Main Street SW, in Airdrie, Alberta, Canada. The store was built in 2014, and the fire alarm system is original.

System Specifications[edit | edit source]

FACP[edit | edit source]

The building is protected by a Notifier NFS-320C addressable fire alarm system. The panel location is unknown. The system runs Notifier’s FlashScan addressable protocol, and the system coding is temporal.

Annunciators[edit | edit source]

There is a Notifier LCD2-80 annunciator paired with a Notifier ACM-24AT annunciator in the main entrance vestibule.

Notification Appliances[edit | edit source]

All notification appliances are System Sensor “SpectrAlert Advance” P2RA horn/strobes (red, wall-mount, set to 15cd).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are Notifier NBG-12LX addressable dual-action pull stations.

Automatic Detection Devices[edit | edit source]

There is a Notifier FSP-851A addressable photoelectric smoke detector in the electrical room, mounted on a System Sensor B210LPA base.

There are System Sensor DNRA duct smoke detector housings with Notifier FSP-851A addressable photoelectric heads on all air handling units.

Modules[edit | edit source]

There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system's tamper and flow switches.

There are Notifier FRM-1A addressable relay modules serving various purposes.

EOLs[edit | edit source]

There are Notifier EOL-CR end of line resistor plates on all sprinkler and signal circuits.