| FACP: Notifier NFS-320C <br />FACP Location: Electrical Room <br>System Type: Single-Stage Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage:24VDC<br />System Coding: Temporal <br>Strobes Synchronized: Yes, System Sensor <br>Date of last known Upgrade: 2021<br />Year Opened: 1979 | | FACP: Notifier NFS-320C <br />FACP Location: Electrical Room <br>System Type: Single-Stage Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC<br />System Coding: Temporal <br>Strobes Synchronized: Yes, System Sensor <br>Date of last known Upgrade: 2021<br />Year Opened: 1979 | ||
|} | |} | ||
The '''Midnapore Mall''' is a strip mall located at 240 Midpark Way SE, in Calgary, Alberta, Canada. The building was built in 1979 as an indoor shopping mall, and was converted into a strip mall in 2000. The fire alarm system was upgraded in 2021. | The '''Midnapore Mall''' is a strip mall located at 240 Midpark Way SE, in Calgary, Alberta, Canada. The building was built in 1979 as an indoor shopping mall, and was converted into a strip mall in 2000. The fire alarm system was upgraded in 2021. | ||
Line 36: | Line 36: | ||
The building was protected by a Mircom Series 1000 conventional fire alarm system. The panel was located in an electrical room. The system coding was likely temporal. | The building was protected by a Mircom Series 1000 conventional fire alarm system. The panel was located in an electrical room. The system coding was likely temporal. | ||
====Notification Appliances==== | ====Notification Appliances==== | ||
Most notification appliances were Edwards 439D-6AWC vibrating bells (6" gong). | |||
Some areas had Mircom BL-6B motor bells (6" gong) as deficiency replacements. | |||
Value Village had Edwards "Durabel" 6100D vibrating bells (10" gong). | |||
===Initiating Devices=== | ===Initiating Devices=== | ||
====Pull Stations==== | ====Pull Stations==== | ||
All pull stations were Mircom MS-401 (single action, conventional) pull stations. | All pull stations were Mircom MS-401 (single action, conventional) pull stations. | ||
====Automatic Detection Devices==== | ====Automatic Detection Devices==== | ||
There were System Sensor C2W-BA conventional photoelectric smoke detectors in some areas. | |||
[[Category:Facilities]] | [[Category:Facilities]] | ||
[[Category:Calgary]] | [[Category:Calgary]] | ||
[[Category:Shopping Malls]] | [[Category:Shopping Malls]] |
Latest revision as of 13:02, 13 October 2024
System Specifications |
---|
FACP: Notifier NFS-320C FACP Location: Electrical Room System Type: Single-Stage Addressable System Line Voltage: 120VAC NAC Voltage: 24VDC System Coding: Temporal Strobes Synchronized: Yes, System Sensor Date of last known Upgrade: 2021 Year Opened: 1979 |
The Midnapore Mall is a strip mall located at 240 Midpark Way SE, in Calgary, Alberta, Canada. The building was built in 1979 as an indoor shopping mall, and was converted into a strip mall in 2000. The fire alarm system was upgraded in 2021.
System Specifications[edit | edit source]
FACP[edit | edit source]
The building is protected by a Notifier NFS-320C addressable fire alarm system. The panel is located in an electrical room. The system runs Notifier's FlashScan addressable protocol, and the system coding is temporal.
Notification Appliances[edit | edit source]
All notification appliances are System Sensor "L-Series" P2RLA horn/strobes (red, wall-mount, set to 15cd).
Initiating Devices[edit | edit source]
Pull Stations[edit | edit source]
All pull stations are Notifier N-MPS-SA addressable single-action pull stations.
Automatic Detection Devices[edit | edit source]
None noticed.
Modules[edit | edit source]
There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system's tamper and flow switches.
EOLs[edit | edit source]
There are Notifier EOL-CR end of line resistor plates on all sprinkler and signal circuits.
Former System Specifications[edit | edit source]
System Specifications |
---|
FACP: Mircom FA-1000 FACP Location: Electrical Room System Type: Single-Stage Conventional System Line Voltage: 120VAC NAC Voltage: 24VFWR System Coding: Temporal Date of last known Upgrade: Mid-2000s Year Decommissioned: 2020 |
FACP[edit | edit source]
The building was protected by a Mircom Series 1000 conventional fire alarm system. The panel was located in an electrical room. The system coding was likely temporal.
Notification Appliances[edit | edit source]
Most notification appliances were Edwards 439D-6AWC vibrating bells (6" gong).
Some areas had Mircom BL-6B motor bells (6" gong) as deficiency replacements.
Value Village had Edwards "Durabel" 6100D vibrating bells (10" gong).
Initiating Devices[edit | edit source]
Pull Stations[edit | edit source]
All pull stations were Mircom MS-401 (single action, conventional) pull stations.
Automatic Detection Devices[edit | edit source]
There were System Sensor C2W-BA conventional photoelectric smoke detectors in some areas.