Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

Super 8 by Wyndham St. Johns: Difference between revisions

From FireAlarmPedia
(Another basic EST system.)
 
No edit summary
 
(6 intermediate revisions by 3 users not shown)
Line 5: Line 5:
|  
|  
|-
|-
| FACP: EST Quickstart QS4<br />System Type: Addressable<br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />Date of last known Upgrade: N/A <br />Year Opened: 2006
| FACP: EST QuickStart QS4 <br> FACP Location: Main Entrance<br />System Type: Single-Stage Addressable<br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br> System Coding: Temporal <br> Strobes Synchronized: Yes, EST Self-Sync <br />Date of last known Upgrade: N/A <br />Year Opened: 2006 <br> Floor Count: 4
|}
|}
 
'''Super 8''' is the world’s largest chain of budget hotels. The company was founded in Aberdeen, South Dakota, in 1974. Today, the company is owned and operated by Wyndham, and is headquartered in Parsippany, New Jersey. This particular hotel is located at 175 Higgins Line, St. John's, Newfoundland & Labrador. It opened its doors in 2006, and still retains the original system.
‘’’’Super 8’’’’ is the world’s largest chain of budget hotels. The company was founded in Aberdeen, South Dakota, in 1974. Today, the company is owned and operated by Wyndham, and is headquartered in Parsippany, New Jersey. This particular hotel is located in St. Johns, Newfoundland. It opened its doors in 2006, and still retains the original system.
==System Specifications (2006-present)==
 
==System Specifications==
====FACP====
====FACP====
The hotel is protected by an EST Quickstart QS4 addressable fire alarm system. The panel is located at the main entrance. The system runs EST’s Signature-series addressable protocol, and does code 3 in alarm.
The hotel is protected by an EST QuickStart QS4 addressable fire alarm system. The panel is located at the main entrance. The system runs EST’s Signature addressable protocol, and the system coding is temporal.  
 
=====Annunciators=====
=====Annunciators=====
There is an EST Quickstart QS4-CPU-1 annunciator located behind the front desk.
There is an EST QuickStart QSA-2-S annunciator located behind the front desk. The annunciator is equipped with an EST QS4-CPU-2 control card and two SL30 zone annunciation cards.
 
====Notification Appliances====
====Notification Appliances====
Most notification appliances are EST “Genesis” G1R-HDVM horn/strobes (red, wall-mount, no lettering).  These are located in the hallways, lobby, and pool area. The rooms have Edwards 682-1A-HR mini horns (red, wall-mount).
=====Common Areas=====
 
There are Edwards "Genesis" G1R-HDVM horn/strobes (red, wall-mount, no lettering, set to 15cd) throughout the hotel's common areas.
=====Guest Rooms=====
All guest rooms have Edwards 683-1CR mini-horns (red, wall-mount).
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations are EST SIGA-270 Signature-series addressable single-action pull stations.
All pull stations are EST SIGA-270 addressable single-action pull stations.
====Automatic Detection Devices====
There are EST SIGA-IS addressable ionization smoke detectors throughout the hotel, mounted on EST SIGA-SB bases. Some areas have EST SIGA-PD addressable photoelectric smoke detectors as deficiency replacements.
====Modules====
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches.


====Automatic Detection Devices====
==== EOLs ====
There are EST SIGA-PS Signature-series addressable photoelectric smoke detectors throughout the hotel.
There are Edwards EOL-P1 end-of-line resistor plates on all sprinkler and signal circuits.
[[Category:Facilities]]
[[Category:Newfoundland & Labrador]]
[[Category:Hotels]]

Latest revision as of 00:14, 14 October 2024

System Specifications
FACP: EST QuickStart QS4
FACP Location: Main Entrance
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Temporal
Strobes Synchronized: Yes, EST Self-Sync
Date of last known Upgrade: N/A
Year Opened: 2006
Floor Count: 4

Super 8 is the world’s largest chain of budget hotels. The company was founded in Aberdeen, South Dakota, in 1974. Today, the company is owned and operated by Wyndham, and is headquartered in Parsippany, New Jersey. This particular hotel is located at 175 Higgins Line, St. John's, Newfoundland & Labrador. It opened its doors in 2006, and still retains the original system.

System Specifications (2006-present)[edit | edit source]

FACP[edit | edit source]

The hotel is protected by an EST QuickStart QS4 addressable fire alarm system. The panel is located at the main entrance. The system runs EST’s Signature addressable protocol, and the system coding is temporal.

Annunciators[edit | edit source]

There is an EST QuickStart QSA-2-S annunciator located behind the front desk. The annunciator is equipped with an EST QS4-CPU-2 control card and two SL30 zone annunciation cards.

Notification Appliances[edit | edit source]

Common Areas[edit | edit source]

There are Edwards "Genesis" G1R-HDVM horn/strobes (red, wall-mount, no lettering, set to 15cd) throughout the hotel's common areas.

Guest Rooms[edit | edit source]

All guest rooms have Edwards 683-1CR mini-horns (red, wall-mount).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are EST SIGA-270 addressable single-action pull stations.

Automatic Detection Devices[edit | edit source]

There are EST SIGA-IS addressable ionization smoke detectors throughout the hotel, mounted on EST SIGA-SB bases. Some areas have EST SIGA-PD addressable photoelectric smoke detectors as deficiency replacements.

Modules[edit | edit source]

There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches.

EOLs[edit | edit source]

There are Edwards EOL-P1 end-of-line resistor plates on all sprinkler and signal circuits.