| FACP: Notifier NFS-320C <br />FACP Location: Electrical Room? <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br>Strobes Synchronized: Yes, SS <br />Date of last known Upgrade: N/A <br />Year Opened: 2012
| FACP: Notifier NFS-320C <br />FACP Location: Electrical Room? <br />System Type: Single-Stage Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br>Strobes Synchronized: Yes, SS <br />Date of last known Upgrade: N/A <br />Year Opened: 2012
|}
|}
 
'''The Keg''' is a Canadian chain of upscale steakhouse restaurants. This particular restaurant is located at 130 Crowfoot Terrace NW, in Calgary, Alberta, Canada. The restaurant was built in 2012, and the fire alarm system is original.
'''The Keg''' is a Canadian chain of upscale steakhouse restaurants. This particular restaurant is located at 130 Crowfoot Terrace NW, in Calgary, Alberta, Canada. The restaurant was built in 2012, and the fire alarm system is original.
 
==System Specifications==
==System Specifications==
====FACP====
====FACP====
The building is protected by a Notifier NFS-320C addressable fire alarm system. The panel is likely located in an electrical room. The system runs Notifier’s FlashScan addressable protocol, and the system coding is temporal.
The building is protected by a Notifier NFS-320C addressable fire alarm system. The panel is likely located in an electrical room. The system runs Notifier’s FlashScan addressable protocol, and the system coding is temporal.
 
=====Annunciators=====
=====Annunciators=====
There is a Notifier ACM-24AT annunciator in the main entrance vestibule.
There is a Notifier ACM-24AT annunciator in the main entrance vestibule.
====Notification Appliances====
====Notification Appliances====
Most notification appliances are System Sensor “SpectrAlert” P2RA horn/strobes (red, wall-mount, set to 15cd). <br>The bar area has System Sensor PC2WA horn/strobes (white, ceiling-mount, set to 15cd). <br>The outdoor patio and exterior main entrance have System Sensor P2RKA weatherproof horn/strobes (red, wall-mount).
Most notification appliances are System Sensor “SpectrAlert” P2RA horn/strobes (red, wall-mount, set to 15cd). <br>The bar area has System Sensor PC2WA horn/strobes (white, ceiling-mount, set to 15cd). <br>The outdoor patio and exterior main entrance have System Sensor P2RKA weatherproof horn/strobes (red, wall-mount).
 
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations are Notifier N-MPS-SA addressable single-action pull stations.
All pull stations are Notifier N-MPS-SA addressable single-action pull stations.
====Automatic Detection Devices====
====Automatic Detection Devices====
There are Notifier FSP-851A addressable photoelectric smoke detectors throughout the restaurant, mounted on System Sensor B210LPA bases.
There are Notifier FSP-851A addressable photoelectric smoke detectors throughout the restaurant, mounted on System Sensor B210LPA bases.
==== EOLs ====
There are Notifier EOL-CR end-of-line resistor plates on all circuits.
[[Category:Restaurants]]
[[Category:Calgary]]

Latest revision as of 13:04, 14 October 2024

System Specifications
FACP: Notifier NFS-320C
FACP Location: Electrical Room?
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: Yes, SS
Date of last known Upgrade: N/A
Year Opened: 2012

The Keg is a Canadian chain of upscale steakhouse restaurants. This particular restaurant is located at 130 Crowfoot Terrace NW, in Calgary, Alberta, Canada. The restaurant was built in 2012, and the fire alarm system is original.

System Specifications[edit | edit source]

FACP[edit | edit source]

The building is protected by a Notifier NFS-320C addressable fire alarm system. The panel is likely located in an electrical room. The system runs Notifier’s FlashScan addressable protocol, and the system coding is temporal.

Annunciators[edit | edit source]

There is a Notifier ACM-24AT annunciator in the main entrance vestibule.

Notification Appliances[edit | edit source]

Most notification appliances are System Sensor “SpectrAlert” P2RA horn/strobes (red, wall-mount, set to 15cd).
The bar area has System Sensor PC2WA horn/strobes (white, ceiling-mount, set to 15cd).
The outdoor patio and exterior main entrance have System Sensor P2RKA weatherproof horn/strobes (red, wall-mount).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are Notifier N-MPS-SA addressable single-action pull stations.

Automatic Detection Devices[edit | edit source]

There are Notifier FSP-851A addressable photoelectric smoke detectors throughout the restaurant, mounted on System Sensor B210LPA bases.

EOLs[edit | edit source]

There are Notifier EOL-CR end-of-line resistor plates on all circuits.