More actions
No edit summary |
|||
(9 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
'''Tillebrook Provincial Park''' is a provincial park | {| style="float:right;border:2px solid black" | ||
|- | |||
! System Specifications | |||
|- | |||
| | |||
|- | |||
| FACP: EST FireShield FS302G <br /> FACP Location: Main Entrancee <br />System Type: Single-Stage Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br /> System Coding: Temporal <br> Strobes Synchronized <br />Date of System Installation: 2007? <br />Year Opened: 1969 | |||
|} | |||
'''Tillebrook Provincial Park''' is a provincial park located on Township Road 183A, in Tilley, Alberta, Canada. The park contains a day use area and five campground loops. This page will cover the park office, which is the only building with a fire alarm system. The building opened in 1969, and the fire alarm system is from 2007. | |||
== System Specifications == | Note: This fire alarm system is not in use. The system does not have power, and will not detect a fire or warn people. | ||
==System Specifications (2007-present)== | |||
====FACP==== | |||
The building is protected by an EST FireShield FS302G conventional fire alarm system. The panel is located next to the main entrance. The system coding is temporal. | |||
====Notification Appliances==== | |||
The only notification appliance is an EST “Genesis” G1R-HDVM horn/strobe (red, wall-mount). | |||
===Initiating Devices=== | |||
====Pull Stations==== | |||
Both pull stations are Edwards 270-SPO conventional single-action pull stations. | |||
====Automatic Detection Devices==== | |||
There are two Edwards EC30U-3 conventional photoelectric smoke detectors in the building. | |||
==== | ==== EOLs ==== | ||
There are Edwards EOL-P1 end-of-line resistor plates on all circuits. | |||
[[Category:Facilities]] | |||
[[Category:Alberta]] | |||
[[Category:Campgrounds]] | |||
Latest revision as of 16:35, 14 October 2024
System Specifications |
---|
FACP: EST FireShield FS302G FACP Location: Main Entrancee System Type: Single-Stage Conventional System Line Voltage: 120VAC NAC Voltage: 24VFWR System Coding: Temporal Strobes Synchronized Date of System Installation: 2007? Year Opened: 1969 |
Tillebrook Provincial Park is a provincial park located on Township Road 183A, in Tilley, Alberta, Canada. The park contains a day use area and five campground loops. This page will cover the park office, which is the only building with a fire alarm system. The building opened in 1969, and the fire alarm system is from 2007.
Note: This fire alarm system is not in use. The system does not have power, and will not detect a fire or warn people.
System Specifications (2007-present)[edit | edit source]
FACP[edit | edit source]
The building is protected by an EST FireShield FS302G conventional fire alarm system. The panel is located next to the main entrance. The system coding is temporal.
Notification Appliances[edit | edit source]
The only notification appliance is an EST “Genesis” G1R-HDVM horn/strobe (red, wall-mount).
Initiating Devices[edit | edit source]
Pull Stations[edit | edit source]
Both pull stations are Edwards 270-SPO conventional single-action pull stations.
Automatic Detection Devices[edit | edit source]
There are two Edwards EC30U-3 conventional photoelectric smoke detectors in the building.
EOLs[edit | edit source]
There are Edwards EOL-P1 end-of-line resistor plates on all circuits.