Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

Toby Creek Lodge: Difference between revisions

From FireAlarmPedia
mNo edit summary
No edit summary
 
(8 intermediate revisions by 2 users not shown)
Line 5: Line 5:
|  
|  
|-
|-
| FACP: Mircom FA-1000 <br />System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />Date of last known Upgrade: Early 2010s <br />Year Opened: 1979
| FACP: Mircom Series FA-1000
FACP Location: Main Entrance Vestibule<br />System Type: Single-Stage Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR  
 
System Coding: Temporal<br />Date of last known Upgrade: Early 2010s <br />Year Opened: 1979
|}
|}
 
'''Toby Creek Lodge''' was the first lodge to be built in Panorama Mountain Resort. It is a condo building located at 2035 Panorama Drive, Panorama, British Columbia. It also houses the general store. It was built in 1979, and the system was upgraded in 2012, but most of the pull stations are original.
'''Toby Creek Lodge''' is a 2-story condo building in Panorama Mountain Resort, BC. It was the first ever lodge to be in Panorama Mountain Resort, and was built in 1979. It doesn't have its original system, but has the original pull stations. It also has the general store.
== System Specifications (2012-present) ==
 
== System Specifications ==
 
==== FACP ====
==== FACP ====
The building is protected by a Mircom Series FA-1000 conventional fire alarm system. The panel is located in the main entrance vestibule (for the lodge). The system coding is temporal.


The fire alarm panel is a Mircom FA-1000, installed somewhere in 2012-2013. The panel is located in one of the entrances. It likely replaced an Edwards 6500 that was likely original.
The Series 1000 was installed in 2012, replacing the original Edwards Custom 6500.  
 
==== Notification Appliances ====
==== Notification Appliances ====
All notification appliances are Mircom "Select-A-Horn" FH-340R horns (red, wall-mount, set to Broadband).


The notification appliances are Mircom FH-340R horns. They replaced Edwards Adaptabels/Durabels in 2012-2013, because some horns have a round outline behind them.  
They replaced Edwards "Durabel" 6100D vibrating bells, as some horns have a round outline behind them.  
 
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
All pull stations except for one are the original Edwards 270-SPO conventional pull stations.


The pull stations are all original, they are 2nd generation Edwards 270-SPO (classic shield logo, no FIRE ALARM at top). By the doors to the first floor in the right stairwell, there is a Mircom MS-401 which replaced an original Edwards pull station around the early 2010s.
There is one Mircom MS-401 by the doors in the east stairwell, installed as a deficiency replacement.  
 
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
There are Mircom 2W-B "i3" photoelectric smoke detectors in the hallways of the lodge.


There are Mircom 2W-B "i3" photoelectric smoke detectors in the hallways of the lodge. They were installed when the FA-1000 was.
==== EOLs ====
There are Edwards EOL-P1 end-of-line resistor plates on all circuits.
[[Category:Facilities]]
[[Category:British Columbia]]
[[Category:Hotels]]

Latest revision as of 16:36, 14 October 2024

System Specifications
FACP: Mircom Series FA-1000

FACP Location: Main Entrance Vestibule
System Type: Single-Stage Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VFWR

System Coding: Temporal
Date of last known Upgrade: Early 2010s
Year Opened: 1979

Toby Creek Lodge was the first lodge to be built in Panorama Mountain Resort. It is a condo building located at 2035 Panorama Drive, Panorama, British Columbia. It also houses the general store. It was built in 1979, and the system was upgraded in 2012, but most of the pull stations are original.

System Specifications (2012-present)[edit | edit source]

FACP[edit | edit source]

The building is protected by a Mircom Series FA-1000 conventional fire alarm system. The panel is located in the main entrance vestibule (for the lodge). The system coding is temporal.

The Series 1000 was installed in 2012, replacing the original Edwards Custom 6500.

Notification Appliances[edit | edit source]

All notification appliances are Mircom "Select-A-Horn" FH-340R horns (red, wall-mount, set to Broadband).

They replaced Edwards "Durabel" 6100D vibrating bells, as some horns have a round outline behind them.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations except for one are the original Edwards 270-SPO conventional pull stations.

There is one Mircom MS-401 by the doors in the east stairwell, installed as a deficiency replacement.

Automatic Detection Devices[edit | edit source]

There are Mircom 2W-B "i3" photoelectric smoke detectors in the hallways of the lodge.

EOLs[edit | edit source]

There are Edwards EOL-P1 end-of-line resistor plates on all circuits.