West Edmonton Mall Inn: Difference between revisions

From FireAlarmPedia
No edit summary
 
(3 intermediate revisions by the same user not shown)
Line 5: Line 5:
|  
|  
|-
|-
| FACP: EST QuickStart QS4 <br />FACP Location: Unknown <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br />Date of last known Upgrade: 2005 <br />Year Opened: Unknown
| FACP: Edwards EST2<br />FACP Location: Unknown <br />System Type: Single-Stage Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC<br />System Coding: Temporal
Strobes Synchronized: Yes, EST<br />Date of last known Upgrade: N/A<br />Year Opened: 2000
|}
|}


Line 11: Line 12:
This page is for the West Edmonton Mall Inn across the street from the mall. If you are looking for the in-mall Fantasyland Hotel, see [[West Edmonton Mall]].
This page is for the West Edmonton Mall Inn across the street from the mall. If you are looking for the in-mall Fantasyland Hotel, see [[West Edmonton Mall]].


The West Edmonton Mall Inn is a budget hotel that is located steps away from West Edmonton Mall. It located at 17504 90 Ave NW, Edmonton, AB, and is commonly used if the Fantasyland Hotel is full, or for budget. The hotel spans 3 floors, and has an underground parkade. The build date is currently unknown, but underwent a renovation in 2005. The system was most likely installed following the renovation.
The West Edmonton Mall Inn is a budget hotel that is located steps away from West Edmonton Mall. It located at 17504 90 Ave NW, Edmonton, AB, and is commonly used if the Fantasyland Hotel is full, or for budget. The hotel spans 3 floors, and has an underground parkade. The hotel opened in 2000, and the fire alarm system is original.
== System Specifications ==
== System Specifications ==
==== FACP ====
==== FACP ====
The hotel is most likely protected by an EST QuickStart QS4 addressable fire alarm system. The panel location is unknown, and the model is unconfirmed. However, given the size of the building and the initiating devices, it is most likely a QS4. The system runs EST’s Signature addressable protocol, and the system coding is likely temporal.
The hotel is protected by an Edwards EST2 addressable fire alarm system. The panel location is unknown, and the model is unconfirmed. The system runs EST’s Signature addressable protocol, and the system coding is temporal.
==== Notification Appliances ====
==== Notification Appliances ====
===== Common Areas =====
===== Common Areas =====
The notification appliances are Edwards 439D-10AWC vibrating bells (10" gong) behind metal grills throughout the hotel.  
The notification appliances are Edwards "Integrity" 757-5A-T horn/strobes (red, wall-mount, 15cd).  
===== Guest Rooms =====
===== Guest Rooms =====
The guest rooms have EST 683-1C mini-horns (white, silenceable).
The guest rooms have General Signal 683-1C mini-horns (white, silenceable).
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
All pull stations are EST SIGA-270 addressable pull stations.  
All pull stations are EST SIGA-270 addressable pull stations.  
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
There are EST SIGA-PS addressable photoelectric smoke detectors located throughout, mounted on SIGA-SB bases. There is also a sprinkler system with waterflow detection.
There are EST SIGA-PS addressable photoelectric smoke detectors located throughout, mounted on SIGA-SB bases.
 
The breakfast room has an Edwards 281B-PL conventional 135°F fixed-temperature/rate-of-rise heat detectors, wired to EST SIGA-CT1 addressable monitor modules.
 
There is also a sprinkler system with waterflow detection.
==== Modules ====
==== Modules ====
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches.
There are EST SIGA-WTM addressable monitor modules supervising the sprinkler system's tamper and flow switches.
 
==== EOLs ====
There are Edwards EOL-P1 end-of-line resistor plates on all sprinkler and signal circuits.
[[Category:Edmonton]]
[[Category:Hotels]]

Latest revision as of 20:25, 14 October 2024

System Specifications
FACP: Edwards EST2
FACP Location: Unknown
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal

Strobes Synchronized: Yes, EST
Date of last known Upgrade: N/A
Year Opened: 2000


This page is for the West Edmonton Mall Inn across the street from the mall. If you are looking for the in-mall Fantasyland Hotel, see West Edmonton Mall.

The West Edmonton Mall Inn is a budget hotel that is located steps away from West Edmonton Mall. It located at 17504 90 Ave NW, Edmonton, AB, and is commonly used if the Fantasyland Hotel is full, or for budget. The hotel spans 3 floors, and has an underground parkade. The hotel opened in 2000, and the fire alarm system is original.

System Specifications[edit | edit source]

FACP[edit | edit source]

The hotel is protected by an Edwards EST2 addressable fire alarm system. The panel location is unknown, and the model is unconfirmed. The system runs EST’s Signature addressable protocol, and the system coding is temporal.

Notification Appliances[edit | edit source]

Common Areas[edit | edit source]

The notification appliances are Edwards "Integrity" 757-5A-T horn/strobes (red, wall-mount, 15cd).

Guest Rooms[edit | edit source]

The guest rooms have General Signal 683-1C mini-horns (white, silenceable).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are EST SIGA-270 addressable pull stations.

Automatic Detection Devices[edit | edit source]

There are EST SIGA-PS addressable photoelectric smoke detectors located throughout, mounted on SIGA-SB bases.

The breakfast room has an Edwards 281B-PL conventional 135°F fixed-temperature/rate-of-rise heat detectors, wired to EST SIGA-CT1 addressable monitor modules.

There is also a sprinkler system with waterflow detection.

Modules[edit | edit source]

There are EST SIGA-WTM addressable monitor modules supervising the sprinkler system's tamper and flow switches.

EOLs[edit | edit source]

There are Edwards EOL-P1 end-of-line resistor plates on all sprinkler and signal circuits.