| FACP: Notifier NFS-640C <br /> FACP Location: Main Entrance <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br /> System Coding: Temporal <br> Strobes Synchronized: Yes, SS <br />Date of last known Upgrade: N/A <br />Year Opened: 2007
| FACP: Notifier NFS-640C <br />FACP Location: Main Entrance Vestibule<br />System Type: Single-Stage Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br>Strobes Synchronized: Yes, System Sensor<br />Date of last known Upgrade: N/A <br />Year Opened: 2007
|}
|}
'''Morris Lofts''' is a condo complex located at 10154 103 Street Northwest, in Edmonton, Alberta, Canada. The building opened in 2007, and the fire alarm system is original.
'''Morris Lofts''' is a condo complex located at 10154 103 St NW, in Edmonton, Alberta, Canada. The building was built in 2007, and the fire alarm system is original.
==System Specifications==
==System Specifications==
====FACP====
====FACP====
Line 15: Line 15:
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations are Notifier MPS-950B conventional single-action pull stations. All stations have Notifier FMM-101A addressable monitor modules attached to them.
All pull stations are Notifier MPS-950B conventional single-action pull stations, wired to Notifier FMM-101A addressable monitor modules.
====Automatic Detection Devices====
====Automatic Detection Devices====
There are likely Notifier FSP-851A addressable photoelectric smoke detectors throughout the common areas, mounted on System Sensor B710LPA low-profile bases.
There are likely Notifier FSP-851A addressable photoelectric smoke detectors throughout the common areas, mounted on Notifier B710LPA low-profile bases.
 
==== EOLs ====
There are Notifier EOL-CR end of line resistor plates on all signal circuits.
[[Category:Residential]]
[[Category:Residential]]
[[Category:Edmonton]]
[[Category:Edmonton]]

Latest revision as of 12:20, 24 October 2024

System Specifications
FACP: Notifier NFS-640C
FACP Location: Main Entrance Vestibule
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: Yes, System Sensor
Date of last known Upgrade: N/A
Year Opened: 2007

Morris Lofts is a condo complex located at 10154 103 St NW, in Edmonton, Alberta, Canada. The building was built in 2007, and the fire alarm system is original.

System Specifications[edit | edit source]

FACP[edit | edit source]

The building is protected by a Notifier NFS-640C addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Notifier’s FlashScan addressable protocol, and the system coding is temporal.

Notification Appliances[edit | edit source]

All known notification appliances are System Sensor “SpectrAlert” P2415A horn/strobes (red, wall-mount, 15cd).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are Notifier MPS-950B conventional single-action pull stations, wired to Notifier FMM-101A addressable monitor modules.

Automatic Detection Devices[edit | edit source]

There are likely Notifier FSP-851A addressable photoelectric smoke detectors throughout the common areas, mounted on Notifier B710LPA low-profile bases.

EOLs[edit | edit source]

There are Notifier EOL-CR end of line resistor plates on all signal circuits.