| FACP: EST 6616 | | FACP: EST 6616 <br>FACP Location: Main Lobby<br />System Type: Single-Stage Conventional <br>System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br>System Coding: Continuous <br>Strobes Synchronized: No<br />Date of last known Upgrade: Mid-1990s<br />Year Opened: 1968 | ||
FACP Location: Main Lobby<br />System Type: Conventional <br | |} | ||
'''Anchor Inn and Suites''' is a hotel located at 3 Path End, Twillingate, Newfoundland. It also contains Georgie's Restaurant. The building was built in 1968, and the fire alarm system was upgraded in the mid-1990s. | |||
==System Specifications (mid 1990s-present)== | |||
Please note that these system details are accurate as of 2019, and the system may have been upgraded since. This page should not be used for official purposes. | |||
====FACP==== | ====FACP==== | ||
The building is protected by an EST 6616 16-zone conventional fire alarm system. The panel is located across from the front desk | The building is protected by an EST 6616 16-zone conventional fire alarm system. The panel is located across from the front desk. The system coding is likely continuous. | ||
====Notification Appliances==== | ====Notification Appliances==== | ||
Most notification appliances are Edwards 439D-6AWC vibrating bells (6" gong). There are also EST "Integrity" 202-5A- | Most notification appliances are Edwards 439D-6AWC vibrating bells (6" gong). | ||
Captain's Pub has an Edwards 439D-10AWC vibrating bell (10" gong) due to higher ambient noise levels. | |||
There are also EST "Integrity" 202-5A-001 remote strobes (red, wall-mount, 15cd) throughout the hotel. | |||
===Initiating Devices=== | ===Initiating Devices=== | ||
====Pull Stations==== | ====Pull Stations==== | ||
All pull stations are Edwards 270-SPO conventional single-action pull stations. | All pull stations are Edwards 270-SPO conventional single-action pull stations. | ||
====Automatic Detection Devices==== | ====Automatic Detection Devices==== | ||
There are Edwards | There are Edwards 6250B conventional ionization smoke detectors throughout the hotel. | ||
==== EOLs ==== | |||
There are Edwards EOL-P1 end of line resistor plates on all circuits. | |||
==Bonus Information== | ==Bonus Information== | ||
*The restaurant in this hotel, Georgie's, is very good, and is highly recommended by the staff of this Wiki. | *The restaurant in this hotel, Georgie's, is very good, and is highly recommended by the staff of this Wiki. | ||
[[Category:Newfoundland & Labrador]] | |||
[[Category:Hotels]] | |||
Latest revision as of 13:08, 22 December 2024
| System Specifications |
|---|
| FACP: EST 6616 FACP Location: Main Lobby System Type: Single-Stage Conventional System Line Voltage: 120VAC NAC Voltage: 24VFWR System Coding: Continuous Strobes Synchronized: No Date of last known Upgrade: Mid-1990s Year Opened: 1968 |
Anchor Inn and Suites is a hotel located at 3 Path End, Twillingate, Newfoundland. It also contains Georgie's Restaurant. The building was built in 1968, and the fire alarm system was upgraded in the mid-1990s.
System Specifications (mid 1990s-present)
Please note that these system details are accurate as of 2019, and the system may have been upgraded since. This page should not be used for official purposes.
FACP
The building is protected by an EST 6616 16-zone conventional fire alarm system. The panel is located across from the front desk. The system coding is likely continuous.
Notification Appliances
Most notification appliances are Edwards 439D-6AWC vibrating bells (6" gong).
Captain's Pub has an Edwards 439D-10AWC vibrating bell (10" gong) due to higher ambient noise levels.
There are also EST "Integrity" 202-5A-001 remote strobes (red, wall-mount, 15cd) throughout the hotel.
Initiating Devices
Pull Stations
All pull stations are Edwards 270-SPO conventional single-action pull stations.
Automatic Detection Devices
There are Edwards 6250B conventional ionization smoke detectors throughout the hotel.
EOLs
There are Edwards EOL-P1 end of line resistor plates on all circuits.
Bonus Information