1000 Peaks Lodge: Difference between revisions

From FireAlarmPedia
(Added additional system type info in accordance with new rules.)
(Added province category. Previous update was adding isolators, relays and EOLs. Removed sprinkler info from ADD section.)
 
(One intermediate revision by the same user not shown)
Line 24: Line 24:
All pull stations are EST SIGA-270 addressable single-action pull stations.
All pull stations are EST SIGA-270 addressable single-action pull stations.
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
There are EST SIGA2-PS addressable photoelectric smoke detectors throughout the building, mounted on EST SIGA-SB bases. There is also a sprinkler system with waterflow detection.
There are EST SIGA2-PS addressable photoelectric smoke detectors throughout the building, mounted on EST SIGA-SB bases.
==== Modules ====
==== Modules ====
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches.
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches.
There are EST SIGA-CR addressable relay modules serving various purposes.
There are EST SIGA-IM addressable isolator modules on the SLC.
==== EOLs ====
There are Edwards EOL-P1 end of line resistor plates on all sprinkler and signal circuits.
[[Category:British Columbia]]
[[Category:Hotels]]
[[Category:Hotels]]

Latest revision as of 13:11, 22 December 2024

System Specifications
FACP: EST iO500
FACP Location: Unknown
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Temporal
Strobes Synchronized: N/A
Date of last known Upgrade: N/A
Year Opened: 2015

1000 Peaks Lodge, also known as Peaks Lodge, is a 5-story condo building located at 2064 Summit Drive, Panorama Mountain Resort, in British Columbia, Canada. The lodge opened in 2015, and replaced the original lodge which was lost to a fire in 2013. The fire alarm system is original.


System Specifications (2015-present)[edit | edit source]

FACP[edit | edit source]

The building is protected by an EST iO500 addressable fire alarm system. The panel location is unknown. The system runs EST's Signature addressable protocol, and the system coding is temporal.

Annunciators[edit | edit source]

There is an EST RLCD-C annunciator paired with an EST RLED24 LED annunciator in the elevator area. Both annunciators are mounted inside an EST RA-ENC2 enclosure.

Notification Appliances[edit | edit source]

Common Areas[edit | edit source]

All common area notification appliances are Edwards 439D-10AWC vibrating bells (10" gong).

Units[edit | edit source]

The units have Edwards 683-1C silenceable mini-horns (white, wall-mount).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are EST SIGA-270 addressable single-action pull stations.

Automatic Detection Devices[edit | edit source]

There are EST SIGA2-PS addressable photoelectric smoke detectors throughout the building, mounted on EST SIGA-SB bases.

Modules[edit | edit source]

There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches.

There are EST SIGA-CR addressable relay modules serving various purposes.

There are EST SIGA-IM addressable isolator modules on the SLC.

EOLs[edit | edit source]

There are Edwards EOL-P1 end of line resistor plates on all sprinkler and signal circuits.