Winfield Agriplex: Difference between revisions

From FireAlarmPedia
(upgrades happening!)
No edit summary
 
(8 intermediate revisions by the same user not shown)
Line 5: Line 5:
|  
|  
|-
|-
| FACP: EST 6601 (Inoperable)<br />FACP Location: Lobby, Hall Side <br />System Type: Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Continuous <br />Date of last known Upgrade: 2024<br />Year Opened: 1950s
| FACP: Mircom FA-106<br />FACP Location: Lobby, Hall Side <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal<br />Date of last known Upgrade: 2024<br />Year Opened: 1950s
|}
|}
'''Winfield Agriplex''' is a multi-use building located at 401 6 St E, Wetaskiwin County, AB. It consists of a hall and arena; it was originally built as the Winfield Arena (now Woody Johnson Arena) in the 1950s, and was expanded around 1986 to add the hall. The fire alarm system was upgraded in the early 1980s for the lobby and arena, and the hall's bells are original; the panel was replaced around 1994.
'''Winfield Agriplex''' is a multi-use building located at 401 6 St E, Wetaskiwin County, AB. It consists of a hall and arena; it was originally built as the Winfield Arena (now Woody Johnson Arena) in the 1950s, and was expanded around 1986 to add the hall. The fire alarm system was upgraded around 1983 for the lobby and arena, the hall's bells are original; the fire alarm system was partially upgraded in 2024.
 
The system will be upgraded this year, as the panel has failed as of 2023 and therefore the system does not work. However, the hall pull stations were upgraded in 2024.
== System Specifications (1980s-present) ==
== System Specifications (1980s-present) ==
==== FACP ====
==== FACP ====
The building is protected by an EST 6601 conventional fire alarm system. The panel is located on the south the lobby near the hall, and is also noticeably mounted high. The system coding is continuous. As of October 2023, the panel has suffered a main board failure, and is stuck in alarm. Therefore, the system is no longer functional; the system was last active around 2020.  
The building is protected by a Mircom FA-106 conventional fire alarm system. The panel is located on the south the lobby near the hall. The system coding is temporal.  
 
The FA-106 replaced an EST 6601 in 2024 after a panel failure, which replaced an Edwards 1527 around 1995.  
==== Notification Appliances ====
==== Notification Appliances ====
All notification appliances in the lobby and arena are Chubb 960-1033 vibrating bells (10” gong). There is also one installed outdoors for exterior notification.  
Most notification appliances in the lobby and arena hallways are Chubb 960-1033 vibrating bells (10” gong).
 
There are some Edwards 439D-10AWC vibrating bells (10" gong) in the same areas, installed in 1986.
 
There is a Mircom BL-10B motor bell (10" gong) in the arena as a deficiency replacement for an Edwards 439D-10AWC.  


The hall has Edwards 439D-6AWC vibrating bells (6" gong).  
The hall portion has Edwards 439D-6AWC vibrating bells (6" gong).  
 
For exterior notification, there is a Chubb 960-1033 vibrating bell outside the entrance. 
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
Most pull stations are Sentron 303 conventional pull stations in the arena and lobby.<br>There are some Sentron 304 conventional two-stage pull stations, wired as single-stage.
The lobby and arena mostly have Sentron 303 conventional single-action pull stations.<br>There are some Sentron 304 conventional two-stage pull stations, wired as single-stage.


The hall has Mircom MS-401 conventional single-action pull stations; these replaced Edwards 274-111 conventional single-action pull stations in 2024.
The hall has Mircom MS-401 conventional single-action pull stations; these replaced Edwards 274-111 conventional single-action pull stations in 2024.
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
Most heat detectors are Edwards 281C rate-of-rise/fixed heat detectors, mostly in the hall but can be found in the arena.  
There are Mircom 5601A conventional 135°F fixed-temperature/rate-of-rise heat detectors throughout the facility, installed in 2024.
 
These replaced Edwards 281C conventional 135°F fixed-temperature/rate-of-rise heat detectors throughout, with some Sentron 320 conventional 135°F fixed-temperature/rate-of-rise heat detectors.  


The arena and Olympia Room also have Sentron 320 rate-of-rise/fixed temperature heat detectors.
==== EOLs ====
There are Edwards EOL-P1 end-of-line resistor plates on all circuits.
[[Category:Arenas]]
[[Category:Community Centres]]
[[Category:Alberta]]

Latest revision as of 00:20, 26 December 2024

System Specifications
FACP: Mircom FA-106
FACP Location: Lobby, Hall Side
System Type: Single-Stage Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Temporal
Date of last known Upgrade: 2024
Year Opened: 1950s

Winfield Agriplex is a multi-use building located at 401 6 St E, Wetaskiwin County, AB. It consists of a hall and arena; it was originally built as the Winfield Arena (now Woody Johnson Arena) in the 1950s, and was expanded around 1986 to add the hall. The fire alarm system was upgraded around 1983 for the lobby and arena, the hall's bells are original; the fire alarm system was partially upgraded in 2024.

System Specifications (1980s-present)[edit | edit source]

FACP[edit | edit source]

The building is protected by a Mircom FA-106 conventional fire alarm system. The panel is located on the south the lobby near the hall. The system coding is temporal.

The FA-106 replaced an EST 6601 in 2024 after a panel failure, which replaced an Edwards 1527 around 1995.

Notification Appliances[edit | edit source]

Most notification appliances in the lobby and arena hallways are Chubb 960-1033 vibrating bells (10” gong).

There are some Edwards 439D-10AWC vibrating bells (10" gong) in the same areas, installed in 1986.

There is a Mircom BL-10B motor bell (10" gong) in the arena as a deficiency replacement for an Edwards 439D-10AWC.

The hall portion has Edwards 439D-6AWC vibrating bells (6" gong).

For exterior notification, there is a Chubb 960-1033 vibrating bell outside the entrance.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

The lobby and arena mostly have Sentron 303 conventional single-action pull stations.
There are some Sentron 304 conventional two-stage pull stations, wired as single-stage.

The hall has Mircom MS-401 conventional single-action pull stations; these replaced Edwards 274-111 conventional single-action pull stations in 2024.

Automatic Detection Devices[edit | edit source]

There are Mircom 5601A conventional 135°F fixed-temperature/rate-of-rise heat detectors throughout the facility, installed in 2024.

These replaced Edwards 281C conventional 135°F fixed-temperature/rate-of-rise heat detectors throughout, with some Sentron 320 conventional 135°F fixed-temperature/rate-of-rise heat detectors.

EOLs[edit | edit source]

There are Edwards EOL-P1 end-of-line resistor plates on all circuits.