More actions
mNo edit summary |
Twentytwo22 (talk | contribs) No edit summary |
||
(5 intermediate revisions by 2 users not shown) | |||
Line 5: | Line 5: | ||
| | | | ||
|- | |- | ||
| FACP: EST iO1000 <br />System Type: Hybrid <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />Date of last update: December 2021 <br />Year Installed: | | FACP: EST iO1000 | ||
FACP Location: Basement Furnace Room<br />System Type: Hybrid <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR | |||
System Coding: Temporal<br />Date of last update: December 2021 <br />Year Installed: 2017 | |||
|} | |} | ||
'''ThePurpleMage’s''' house is a split level house in the community of Lake Bonavista. | |||
ThePurpleMage’s house is a split level house in the community of Lake Bonavista. | |||
The house was built in 1973. | The house was built in 1973. | ||
<br> Note: This system is owned and controlled by a user of this wiki, and can activate it at any time because it is in a controlled environment. NEVER pull a fire alarm unless there is actually a fire emergency. The staff on this wiki are not responsible for your actions if you get fined. | <br> Note: This system is owned and controlled by a user of this wiki, and can activate it at any time because it is in a controlled environment. NEVER pull a fire alarm unless there is actually a fire emergency. The staff on this wiki are not responsible for your actions if you get fined. | ||
==System Specifications== | == System Specifications== | ||
====FACP==== | ====FACP ==== | ||
The house is protected by an EST iO1000 Addressable fire alarm | The house is protected by an EST iO1000 Addressable fire alarm system. The panel is located in the basement furnace/boiler room. The panel replaced an Edwards 2280 in December of 2021. | ||
The system runs EST's Signature-series addressable protocol, and the system coding is Temporal. | |||
====Notification Appliances==== | ====Notification Appliances ==== | ||
The Notification Appliances consist of a mix of Edwards 439D-6AWC (6 | The Notification Appliances consist of a mix of Edwards 439D-6AWC (6" gong) vibrating bells and Simplex 2901-9723 motor bells (6" gong) | ||
===Initiating Devices=== | ===Initiating Devices=== | ||
====Pull Stations==== | ====Pull Stations==== | ||
The manual pull stations consist of Notifier MPS-950B | The manual pull stations consist of Notifier MPS-950B conventional single action pull stations and Notifier LNG-1R (Red) dual action conventional pull stations. These pull stations are wired into EST SIGA CT-1 monitor modules. | ||
====Automatic Detection Devices==== | ====Automatic Detection Devices==== | ||
The Automatic Detection Devices consist of EST SIGA | The Automatic Detection Devices consist of EST SIGA-PD addressable photoelectric smoke detectors. | ||
[[Category:Facilities]] |
Latest revision as of 15:09, 2 April 2023
System Specifications |
---|
FACP: EST iO1000
FACP Location: Basement Furnace Room System Coding: Temporal |
ThePurpleMage’s house is a split level house in the community of Lake Bonavista.
The house was built in 1973.
Note: This system is owned and controlled by a user of this wiki, and can activate it at any time because it is in a controlled environment. NEVER pull a fire alarm unless there is actually a fire emergency. The staff on this wiki are not responsible for your actions if you get fined.
System Specifications[edit | edit source]
FACP[edit | edit source]
The house is protected by an EST iO1000 Addressable fire alarm system. The panel is located in the basement furnace/boiler room. The panel replaced an Edwards 2280 in December of 2021.
The system runs EST's Signature-series addressable protocol, and the system coding is Temporal.
Notification Appliances[edit | edit source]
The Notification Appliances consist of a mix of Edwards 439D-6AWC (6" gong) vibrating bells and Simplex 2901-9723 motor bells (6" gong)
Initiating Devices[edit | edit source]
Pull Stations[edit | edit source]
The manual pull stations consist of Notifier MPS-950B conventional single action pull stations and Notifier LNG-1R (Red) dual action conventional pull stations. These pull stations are wired into EST SIGA CT-1 monitor modules.
Automatic Detection Devices[edit | edit source]
The Automatic Detection Devices consist of EST SIGA-PD addressable photoelectric smoke detectors.