''Note: This page is being heavily edited due to the fire alarm system currently getting installed in a new house.''
[[Category:Hobby]]
 
{| style="float:right;border:2px solid black"
|-
!System Specifications
|-
|
|-
|FACP: EST Quickstart QS1<br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR (Panel NACs)
24VDC (Booster)
System Type: Addressable (Hybrid Manner)<br />Date of last upgrade: March 15, 2021<br />Year Built: 1966
|-
|
|}
The original '''Twentytwo22's Garage''' was a small residential garage in Sundance, built in 1994. The system was owned by User:Twentytwo22
The original '''Twentytwo22's Garage''' was a small residential garage in Sundance, built in 1994. The system was owned by User:Twentytwo22
As of September 1st, 2020 Twentytwo22 has moved to a location in Glenbrook. <br> The new garage was built in 1966 and plans to add period specific Initiating Devices (except automatic detection) and Notification Appliances are considered.
As of September 1st, 2020 Twentytwo22 has moved to a location in Glenbrook. <br> The new garage was built in 1966 and plans to add period specific Initiating Devices (except automatic detection) and Notification Appliances are considered.
== System Specifications ==
==System Specifications==
*Note: The system is currently getting installed, so it is not complete.
====FACP====
==== FACP ====
The fire alarm panel is an EST (GE) QuickStart QS1 (addressable) from the early 2010s (circuitboard is from 2008) with the PS6 power supply card and one SLIC card. The system was upgraded from a conventional EST QuickStart QSC (made 2005) in February 2021 due to the failure of the QSC CPU and a QS1 CPU being the only replacement available. The QS1 CPU is on the QSC's cabinet.
 
<br>The panel was transferred over from the old garage. The panel is currently setup in a Single stage manner. When activated the bells do Code-3.
The fire alarm panel is an EST Quickstart QSC (conventional) with the PS6 power supply card and one ZB16 card.
====Notification Appliances====
<br> Most of the zones were unused and simply have a resistor across them due to the small size of the garage. The panel was transferred over from the old garage. The panel will be setup as a timed two-stage system with an "evacuate" key switch to force the system into second stage before the 5 minute timer ends.  
The notification appliances consist of a Wheelock 34T-24 mechanical horn on a Wheelock RSSP-2415W-FR strobe plate (15cd), an ADT horn, an Edwards Durabel 6100D in the attic, and 3 Wheelock "Exceeder" STWC remote strobes (white, ceiling-mount). The horns are on a Notifier FCPS-24S8C 8-amp booster panel, as filtered DC was necessary for these devices.
In first stage the panel will do 20bpm (slow march) and 120bpm March time in second stage.
 
==== Notification Appliances ====
 
The notification appliances consist of a Simplex 2901-9722 10" motor bell. An Edwards "Durabel" 6100D vibrating bell (6" gong, 1964 gen) and an EST Genesis G1-VM (white, no fire marking) remote strobe will be installed in the attic. Twentytwo22 has plans install a Wheelock RSSP-2415W-FR strobe plate, a Notifier KMS-10-24A motor bell, and three Wheelock "Exceder" STWC (white, ceiling) remote strobes.
 
=== Initiating Devices ===
 
==== Pull Stations ====
 
Currently, the only pull station installed as of 12/27/2020 is a Fire-Lite BG-12L (keylock) a section of drywall directly above the BG-12L was temporarily removed to aid in running wires.  
 
==== Automatic Detection Devices ====
 
There was is automatic detection device, a System Sensor C4W-B (i3) smoke detector.
 
== System Specifications (Original Garage) ==


[[File:Ac-bell-modern-panel-circuit.png]]
===Initiating Devices===
====Pull Stations====
Currently, there is is a Simplex 2099-9754 at the man-door. (A section of drywall directly above it was temporarily removed to aid in running wires), a vintage Edwards 270-SPO (1970s) at the overhead door, and another vintage Edwards 270-SPO (2nd Generation) is installed in the attic. (both salvaged from [[7044 Ogden Road SE]])
====Automatic Detection Devices====
There is one automatic detection device, an ADT Rebrand of an EST SIGA-PS (ADT-PS) installed beside the door opener on the main floor.
==System Specifications (Original Garage)==
====FACP====
====FACP====
The fire alarm panel was an EST Quickstart QSC (conventional) with the PS6 power supply card and one ZB16 card. Most of the Zones were unused and simply have a resistor across them due to the small size of the garage. Now in use on the new garage.
The fire alarm panel was an EST Quickstart QSC (conventional) with the PS6 power supply card and one ZB16 card. Most of the Zones were unused and simply had a resistor across them due to the small size of the garage. Now in use on the new garage.
 
====Notification Appliances====
====Notification Appliances====
The two notification appliances were a Simplex 2901-9722 10" motor bell installed to accommodate owner preference and one EST Genesis G1-VM (white, no fire marking) remote strobe. The 2901-9722 was previously used in a school, and is still in use on the new garage. Formerly, there was a Gentex "Commander 3" GEC3-24WR (red, wall) horn/strobe.
The two notification appliances were a Simplex 2901-9722 10" motor bell installed to accommodate owner preference and one EST Genesis G1-VM (white, no fire marking) remote strobe. The 2901-9722 was previously used in a school, and is still in use on the new garage. Formerly, there was a Gentex "Commander 3" GEC3-24WR (red, wall) horn/strobe.
 
===Initiating Devices===
=== Initiating Devices ===
====Pull Stations====
====Pull Stations====
The pull stations consisted of one Chinese Pull Station, one Fire-Lite BG-12L and one GE-branded Edwards 270-SPO.
The pull stations consisted of one Chinese Pull Station, one Fire-Lite BG-12L and one GE-branded Edwards 270-SPO.
====Automatic Detection Devices====
====Automatic Detection Devices====
There was one automatic detection device, a System Sensor C4W-B (i3) smoke detector that replaced a two wire equivalent. (C2W-BA)
There was one automatic detection device, a System Sensor C4W-B (i3) smoke detector that replaced a two wire equivalent. (C2W-BA)
[[Category:Facilities]]
[[Category:Facilities]]
==New Garage Installation Photos==
==New Garage Installation Photos==
<gallery>
<gallery>
2222gWiring12272020.jpg|The panel as it looked on December 27th, 2020 at this point the wiring for the back pull station and the Notifier bell had not yet been run.
2222gWiring12272020.jpg|The panel as it looked on December 27th, 2020 at this point the wiring for the back pull station and the Notifier bell had not yet been run.
Line 51: Line 47:
2222gstwc2.jpg|The second STWC in the Wheelock circuit located near the furnace.
2222gstwc2.jpg|The second STWC in the Wheelock circuit located near the furnace.
2222gstwc1.jpg|The first Strobe in the Wheelock circuit wired directly after the RSSP.  
2222gstwc1.jpg|The first Strobe in the Wheelock circuit wired directly after the RSSP.  
G1-avrf.jpg|The modified "Genesis LED" G1-AVRF Horn/Strobe shortly after installation. (Note the piece of plywood required to give the extra clearance needed by the device.)
</gallery>
</gallery>
==Installation Videos==
==Installation Videos==
Testing the Modified G1-AVRF "Genesis LED" horn-strobe (converted to remote strobe)  
Testing the Modified G1-AVRF "Genesis LED" horn-strobe (converted to remote strobe)
[[File:LgenesisTest.mp4]]
[[File:LgenesisTest.mp4]]
==Live "Virtual Printer" Feed==
<html><div id="fTelnetContainer" class="fTelnetContainer"></div>
<script>document.write('<script src="//embed-v2.ftelnet.ca/js/ftelnet-loader.norip.noxfer.js?v=' + (new Date()).getTime() + '"><\/script>');</script>
<script>
    var Options = new fTelnetOptions();
    Options.BareLFtoCRLF = false;
    Options.BitsPerSecond = 57600;
    Options.ConnectionType = 'telnet';
    Options.Emulation = 'ansi-bbs';
    Options.Enter = '\r';
    Options.Font = 'CP866';
    Options.ForceWss = false;
    Options.Hostname = '70.73.84.56';
    Options.LocalEcho = false;
    Options.NegotiateLocalEcho = true;
    Options.Port = 23;
    Options.ProxyHostname = 'proxy-us-ca.ftelnet.ca';
    Options.ProxyPort = 80;
    Options.ProxyPortSecure = 443;
    Options.ScreenColumns = 80;
    Options.ScreenRows = 25;
    Options.SendLocation = false;
    var fTelnet = new fTelnetClient('fTelnetContainer', Options);
    fTelnet.Connect();
</script></html>
You can also view past events [http://70.73.84.56:380/panel.txt here.]
[[Category:Facilities]]

Latest revision as of 15:10, 2 April 2023

System Specifications
FACP: EST Quickstart QS1
System Line Voltage: 120VAC
NAC Voltage: 24VFWR (Panel NACs)

24VDC (Booster) System Type: Addressable (Hybrid Manner)
Date of last upgrade: March 15, 2021
Year Built: 1966

The original Twentytwo22's Garage was a small residential garage in Sundance, built in 1994. The system was owned by User:Twentytwo22 As of September 1st, 2020 Twentytwo22 has moved to a location in Glenbrook.
The new garage was built in 1966 and plans to add period specific Initiating Devices (except automatic detection) and Notification Appliances are considered.

System Specifications[edit | edit source]

FACP[edit | edit source]

The fire alarm panel is an EST (GE) QuickStart QS1 (addressable) from the early 2010s (circuitboard is from 2008) with the PS6 power supply card and one SLIC card. The system was upgraded from a conventional EST QuickStart QSC (made 2005) in February 2021 due to the failure of the QSC CPU and a QS1 CPU being the only replacement available. The QS1 CPU is on the QSC's cabinet.
The panel was transferred over from the old garage. The panel is currently setup in a Single stage manner. When activated the bells do Code-3.

Notification Appliances[edit | edit source]

The notification appliances consist of a Wheelock 34T-24 mechanical horn on a Wheelock RSSP-2415W-FR strobe plate (15cd), an ADT horn, an Edwards Durabel 6100D in the attic, and 3 Wheelock "Exceeder" STWC remote strobes (white, ceiling-mount). The horns are on a Notifier FCPS-24S8C 8-amp booster panel, as filtered DC was necessary for these devices.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

Currently, there is is a Simplex 2099-9754 at the man-door. (A section of drywall directly above it was temporarily removed to aid in running wires), a vintage Edwards 270-SPO (1970s) at the overhead door, and another vintage Edwards 270-SPO (2nd Generation) is installed in the attic. (both salvaged from 7044 Ogden Road SE)

Automatic Detection Devices[edit | edit source]

There is one automatic detection device, an ADT Rebrand of an EST SIGA-PS (ADT-PS) installed beside the door opener on the main floor.

System Specifications (Original Garage)[edit | edit source]

FACP[edit | edit source]

The fire alarm panel was an EST Quickstart QSC (conventional) with the PS6 power supply card and one ZB16 card. Most of the Zones were unused and simply had a resistor across them due to the small size of the garage. Now in use on the new garage.

Notification Appliances[edit | edit source]

The two notification appliances were a Simplex 2901-9722 10" motor bell installed to accommodate owner preference and one EST Genesis G1-VM (white, no fire marking) remote strobe. The 2901-9722 was previously used in a school, and is still in use on the new garage. Formerly, there was a Gentex "Commander 3" GEC3-24WR (red, wall) horn/strobe.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

The pull stations consisted of one Chinese Pull Station, one Fire-Lite BG-12L and one GE-branded Edwards 270-SPO.

Automatic Detection Devices[edit | edit source]

There was one automatic detection device, a System Sensor C4W-B (i3) smoke detector that replaced a two wire equivalent. (C2W-BA)