8327 48 Avenue Garage is a small residential garage in Bowness, built in 1975. The system is currently owned by [[User:AdenK2333]].
'''''NOTE''''': ''This page is unsupported and no longer maintained due to a dispute between this user and Fire Alarmpedia staff. However, it will remain accessible for historical purposes.''
 
'''8327 48 Avenue Garage''' is a small residential garage in Calgary, built in 1975. The system is currently owned by [[User:AdenK2333]].


== System Specifications ==
== System Specifications ==
==== FACP ====
==== FACP ====
The fire alarm panel is an ADT Unimode 10UD-7. Most of the zones are unused and simply have a resistor across them due to the small size of the garage.
The fire alarm panel is a Mircom FA-102T. When the system is in ALARM, the coding is on continuous NAC 1.
 
==== Notification Appliances ====
==== Notification Appliances ====
The one notification appliance is a Wheelock MT-241575W-FR 15/75cd Multi-Tone 4 wire Horn/Strobe (Wall/Red) set on steady horn. The panel’s coding is on March Time for NAC 1 (Horn NAC) and Wheelock Sync for NAC 2 (Strobe NAC). NAC 2 is non-scilencable.
The notification appliances consist of two System Sensor P2RA horn/strobes (2-wire, red, wall mount) set on TEMP3 LOW, 15 cd and a System Sensor PC2RA (2-wire, red, wall mount) set on TEMP3 LOW, 15 cd.
 
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
The pull stations consists of two Edwards 278B-1120s pull stations (key lock, screw terminals).
The pull stations consists of two Mircom MS-401 pull stations (conventional, single action, screw terminals).
 
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
There is one automatic detection device, a System Sensor C2WTA-BA, 2-wire, photoelectric i3 smoke detector with a thermal sensor and a built-in sounder. The sounder was removed due to it being unneccesary and annoying. Freeze supervision for this zone is disabled due to the garage ambient temperature falls below freezing during the winter months.
There is no automatic detection devices installed in the system.
[[Category:Facilities]]
[[]
[[]

Latest revision as of 17:57, 24 November 2023

NOTE: This page is unsupported and no longer maintained due to a dispute between this user and Fire Alarmpedia staff. However, it will remain accessible for historical purposes.

8327 48 Avenue Garage is a small residential garage in Calgary, built in 1975. The system is currently owned by User:AdenK2333.

System Specifications[edit | edit source]

FACP[edit | edit source]

The fire alarm panel is a Mircom FA-102T. When the system is in ALARM, the coding is on continuous NAC 1.

Notification Appliances[edit | edit source]

The notification appliances consist of two System Sensor P2RA horn/strobes (2-wire, red, wall mount) set on TEMP3 LOW, 15 cd and a System Sensor PC2RA (2-wire, red, wall mount) set on TEMP3 LOW, 15 cd.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

The pull stations consists of two Mircom MS-401 pull stations (conventional, single action, screw terminals).

Automatic Detection Devices[edit | edit source]

There is no automatic detection devices installed in the system. [[] [[]