Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

Holiday Inn Express & Suites Springfield North: Difference between revisions

From FireAlarmPedia
(Very)
 
No edit summary
 
(One intermediate revision by one other user not shown)
Line 7: Line 7:
| FACP: Edwards iO1000 <br />FACP Location: Unknown <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Genesis <br />Date of last known Upgrade: N/A <br />Year Opened: 2019
| FACP: Edwards iO1000 <br />FACP Location: Unknown <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Genesis <br />Date of last known Upgrade: N/A <br />Year Opened: 2019
|}
|}
 
'''Holiday Inn Express''' is a chain of budget hotels owned by IHG. The chain is headquartered in Denham, England, and has locations globally. This particular hotel is located at 3050 North Kentwood Avenue, in Springfield, Missouri, USA. The hotel opened in 2019, and the fire alarm system is original.
'''Holiday Inn Express''' is a chain of budget hotels owned by IHG. The chain is headquartered in Denham, England, and has locations globally. This particular hotel is located at 3050 North Kentwood Avenue, in Springfield, Missouri, USA. The hotel opened in 2019, and the fire alarm system is original.
==System Specifications (2019-present)==
 
==System Specifications==
====FACP====
====FACP====
The building is protected by an Edwards iO1000 addressable fire alarm system. The panel location is unknown. The system runs Edwards’ Signature addressable protocol, and the system coding is temporal.
The building is protected by an Edwards iO1000 addressable fire alarm system. The panel location is unknown. The system runs Edwards’ Signature addressable protocol, and the system coding is temporal.
 
=====Annunciators=====
=====Annunciators=====
There is an Edwards RLCD-C annunciator behind the front desk.
There is an Edwards RLCD-C annunciator behind the front desk.
====Notification Appliances====
====Notification Appliances====
There are Edwards “Genesis” GC-HDVM horn/strobes (white, ceiling-mount, set to 15cd) throughout the common areas. All guest rooms have Edwards G1F-VM remote strobes (white, wall-mount, set to 110cd).
There are Edwards “Genesis” GC-HDVM horn/strobes (white, ceiling-mount, set to 15cd) throughout the common areas. All guest rooms have Edwards G1F-VM remote strobes (white, wall-mount, set to 110cd).
 
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations are EST SIGA-278 addressable dual-action pull stations.
All pull stations are EST SIGA-278 addressable dual-action pull stations.
====Automatic Detection Devices====
====Automatic Detection Devices====
There are Edwards SIGA-PD addressable photoelectric smoke detectors throughout the building. These are mounted on Edwards SIGA-SB bases in the common areas, and on Edwards SIGA-AB4G-LF low-frequency sounder bases in all guest rooms.
There are Edwards SIGA-PD addressable photoelectric smoke detectors throughout the building. These are mounted on Edwards SIGA-SB bases in the common areas, and on Edwards SIGA-AB4G-LF low-frequency sounder bases in all guest rooms. There is also a sprinkler system with waterflow detection.
==== Modules ====
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches.
[[Category:Missouri]]
[[Category:Hotels]]

Latest revision as of 17:53, 25 May 2024

System Specifications
FACP: Edwards iO1000
FACP Location: Unknown
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Temporal
Strobes Synchronized: Yes, Genesis
Date of last known Upgrade: N/A
Year Opened: 2019

Holiday Inn Express is a chain of budget hotels owned by IHG. The chain is headquartered in Denham, England, and has locations globally. This particular hotel is located at 3050 North Kentwood Avenue, in Springfield, Missouri, USA. The hotel opened in 2019, and the fire alarm system is original.

System Specifications (2019-present)[edit | edit source]

FACP[edit | edit source]

The building is protected by an Edwards iO1000 addressable fire alarm system. The panel location is unknown. The system runs Edwards’ Signature addressable protocol, and the system coding is temporal.

Annunciators[edit | edit source]

There is an Edwards RLCD-C annunciator behind the front desk.

Notification Appliances[edit | edit source]

There are Edwards “Genesis” GC-HDVM horn/strobes (white, ceiling-mount, set to 15cd) throughout the common areas. All guest rooms have Edwards G1F-VM remote strobes (white, wall-mount, set to 110cd).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are EST SIGA-278 addressable dual-action pull stations.

Automatic Detection Devices[edit | edit source]

There are Edwards SIGA-PD addressable photoelectric smoke detectors throughout the building. These are mounted on Edwards SIGA-SB bases in the common areas, and on Edwards SIGA-AB4G-LF low-frequency sounder bases in all guest rooms. There is also a sprinkler system with waterflow detection.

Modules[edit | edit source]

There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches.