Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

Mechanicville Elementary School: Difference between revisions

From FireAlarmPedia
(And that's all)
 
No edit summary
 
(One intermediate revision by one other user not shown)
Line 7: Line 7:
| FACP: Edwards EST3 <br />FACP Location: Electrical Room? <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Wheelock <br />Date of last known Upgrade: N/A <br />Year Opened: 2003
| FACP: Edwards EST3 <br />FACP Location: Electrical Room? <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Wheelock <br />Date of last known Upgrade: N/A <br />Year Opened: 2003
|}
|}
 
'''Mechanicville Elementary School'''' is an elementary school located at 25 Kniskern Avenue, in Mechanicville, New York, USA. The original school was built in 1915, and demolished in 2003. The new building was built in 2003, and the fire alarm system is original.
'''Mechanicville Elementary School'''' is an elementary school located at 25 Kniskern Avenue, in Mechanicville, New York, USA. The original school was built in 1915, and demolished in 2003. The new building was built in 2003, and the fire alarm system is original.
 
==System Specifications (Current School, 2003-present)==
==System Specifications (Current School, 2003-present)==
====FACP====
====FACP====
The building is protected by an Edwards EST3 addressable fire alarm system. The panel is likely located in an electrical room. The system runs Edwards’ Signature addressable protocol, and the system coding is temporal.
The building is protected by an Edwards EST3 addressable fire alarm system. The panel is likely located in an electrical room. The system runs Edwards’ Signature addressable protocol, and the system coding is temporal.
 
=====Annunciators=====
=====Annunciators=====
There is an Edwards EST3-LCDANN annunciator at the main entrance.
There is an Edwards EST3-LCDANN annunciator at the main entrance.
====Notification Appliances====
====Notification Appliances====
All areas except washrooms have Wheelock NS-24MCW-FR horn/strobes (red, wall-mount, set to 15cd). <br>The washrooms have Wheelock RSS-24MCW remote strobes (red, wall-mount, set to 15cd).
All areas except washrooms have Wheelock NS-24MCW-FR horn/strobes (red, wall-mount, set to 15cd). <br>The washrooms have Wheelock RSS-24MCW remote strobes (red, wall-mount, set to 15cd).
 
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations are EST SIGA-278 addressable dual-action pull stations.
All pull stations are EST SIGA-278 addressable dual-action pull stations.
====Automatic Detection Devices====
====Automatic Detection Devices====
There are EST SIGA-PS addressable photoelectric smoke detectors throughout the building, mounted on EST SIGA-SB bases.
There are EST SIGA-PS addressable photoelectric smoke detectors throughout the building, mounted on EST SIGA-SB bases.
==System Specifications (Original School, 1940s-2003)==
==System Specifications (Original School, 1940s-2003)==
{| style="float:right;border:2px solid black"
{| style="float:right;border:2px solid black"
Line 36: Line 29:
| FACP: IBM 4201-2 <br />FACP Location: Electrical Room? <br />System Type: Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 125VDC <br />System Coding: 4-4 <br>Strobes Synchronized: N/A <br />Date of last known Upgrade: 1960s? <br/> Year Installed: 1940s <br />Year Decommissioned: 2003
| FACP: IBM 4201-2 <br />FACP Location: Electrical Room? <br />System Type: Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 125VDC <br />System Coding: 4-4 <br>Strobes Synchronized: N/A <br />Date of last known Upgrade: 1960s? <br/> Year Installed: 1940s <br />Year Decommissioned: 2003
|}
|}
====FACP====
====FACP====
The building was protected by an IBM 4201-2 conventional fire alarm system. The panel was located in an electrical room. The system coding was 4-4.
The building was protected by an IBM 4201-2 conventional fire alarm system. The panel was located in an electrical room. The system coding was 4-4.
 
====Notification Appliances====
====Notification Appliances====
All notification appliances are IBM RVF-4015-6A vibrating bells (6” gong). As these also doubled as the class change bells, they were single-stroke bells due to DC power.
All notification appliances are IBM RVF-4015-6A vibrating bells (6” gong). As these also doubled as the class change bells, they were single-stroke bells due to DC power. These were used during the final few years of the school.


Prior to that, the notification appliances were IBM R4026-8 single-stroke bells (8" gong). It is unknown why they were disconnected in the 1990s.
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations were IBM 4050 break-glass pull stations.
All pull stations were IBM 4050 break-glass pull stations.
====Automatic Detection Devices====
====Automatic Detection Devices====
None present.
None present.
[[Category:New York]]
[[Category:Schools]]

Latest revision as of 21:11, 25 May 2024

System Specifications
FACP: Edwards EST3
FACP Location: Electrical Room?
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: Yes, Wheelock
Date of last known Upgrade: N/A
Year Opened: 2003

Mechanicville Elementary School' is an elementary school located at 25 Kniskern Avenue, in Mechanicville, New York, USA. The original school was built in 1915, and demolished in 2003. The new building was built in 2003, and the fire alarm system is original.

System Specifications (Current School, 2003-present)[edit | edit source]

FACP[edit | edit source]

The building is protected by an Edwards EST3 addressable fire alarm system. The panel is likely located in an electrical room. The system runs Edwards’ Signature addressable protocol, and the system coding is temporal.

Annunciators[edit | edit source]

There is an Edwards EST3-LCDANN annunciator at the main entrance.

Notification Appliances[edit | edit source]

All areas except washrooms have Wheelock NS-24MCW-FR horn/strobes (red, wall-mount, set to 15cd).
The washrooms have Wheelock RSS-24MCW remote strobes (red, wall-mount, set to 15cd).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are EST SIGA-278 addressable dual-action pull stations.

Automatic Detection Devices[edit | edit source]

There are EST SIGA-PS addressable photoelectric smoke detectors throughout the building, mounted on EST SIGA-SB bases.

System Specifications (Original School, 1940s-2003)[edit | edit source]

Former System Specifications
FACP: IBM 4201-2
FACP Location: Electrical Room?
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage: 125VDC
System Coding: 4-4
Strobes Synchronized: N/A
Date of last known Upgrade: 1960s?
Year Installed: 1940s
Year Decommissioned: 2003

FACP[edit | edit source]

The building was protected by an IBM 4201-2 conventional fire alarm system. The panel was located in an electrical room. The system coding was 4-4.

Notification Appliances[edit | edit source]

All notification appliances are IBM RVF-4015-6A vibrating bells (6” gong). As these also doubled as the class change bells, they were single-stroke bells due to DC power. These were used during the final few years of the school.

Prior to that, the notification appliances were IBM R4026-8 single-stroke bells (8" gong). It is unknown why they were disconnected in the 1990s.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations were IBM 4050 break-glass pull stations.

Automatic Detection Devices[edit | edit source]

None present.