Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

Best Western Plus Calgary Centre Inn: Difference between revisions

From FireAlarmPedia
No edit summary
(Fuck brackets with nothing between them. Also changed the sprinkler monitor module model as in 1999, they were likely using WTMs instead of CT1s.)
 
(One intermediate revision by the same user not shown)
Line 5: Line 5:
|  
|  
|-
|-
| FACP: EST QuickStart QS4<br />System Type: Single-Stage Addressable<br /> System Line Voltage: 120VAC<br />NAC Voltage:24VFWR <br>System Coding: Temporal <br>Strobes Synchronized: Yes<br />Date of last known Upgrade: 2010s <br />Year Opened: 1999
|FACP: Edwards EST2<br />FACP Location: Main Entrance Vestibule<br>System Type: Single-Stage Addressable<br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br>System Coding: Temporal <br>Strobes Synchronized: Yes, Self-Sync<br />Date of last known Upgrade: N/A<br />Year Opened: 1999
|}
|}
'''Best Western''' is a chain of hotels headquartered in Phoenix, Arizona. This particular hotel is located at 3630 Macleod Trail South, in Calgary, Alberta, Canada. The hotel was built in 1999, and the fire alarm system is mostly original.
'''Best Western''' is a chain of hotels headquartered in Phoenix, Arizona. This particular hotel is located at 3630 Macleod Trail South, in Calgary, Alberta, Canada. The hotel was built in 1999, and the fire alarm system is original.
==System Specifications==
==System Specifications==
====FACP====
====FACP====
The hotel is protected by an EST Quickstart QS4 addressable fire alarm system. The panel is located in the main entrance vestibule. This panel was installed in the 2010s, and replaced an EST2. The system runs EST’s Signature addressable protocol, and the system coding is temporal.
The building is protected by an Edwards EST2 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Edwards' Signature addressable protocol, and the system coding is temporal.
====Notification Appliances====
====Notification Appliances====
All common areas have Edwards "Integrity" 757-5A-T horn/strobes (red, wall-mount, 15cd). All guest rooms have Edwards 202-5A-T remote strobes (red, wall-mount, 15cd) and Edwards 683-1CR silenceable mini-horns (red, wall-mount).
All common areas have Edwards "Integrity" 757-5A-T horn/strobes (red, wall-mount, 15cd). <br>All guest rooms have Edwards 202-5A-T remote strobes (red, wall-mount, 15cd) paired with Edwards 683-1CR silenceable mini-horns (red).
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations are EST SIGA-270 addressable single-action pull stations.
All pull stations are EST SIGA-270 addressable single-action pull stations.
====Automatic Detection Devices====
====Automatic Detection Devices====
None noticed, but there are likely EST SIGA-PS addressable photoelectric smoke detectors throughout the corridors.
There are EST SIGA-PS addressable photoelectric smoke detectors throughout all corridors, and at the top of each stairwell, mounted on EST SIGA-SB bases.
====Modules====
====Modules====
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches.
There are EST SIGA-WTM addressable monitor modules supervising the sprinkler system's tamper and flow switches.  <br>There are EST SIGA-CR addressable relay modules serving various purposes.  <br>All signalling circuits utilize EST SIGA-MCC2 signal control modules.
====EOLs====
====EOLs====
There are Edwards EOL-P1 end of line resistor plates on all sprinkler and signal circuits.
There are Edwards EOL-P1 end of line resistor plates on all sprinkler and signal circuits.
[[]
[[Category:Calgary]]
[[Category:Calgary]]
[[Category:Hotels]]
[[Category:Hotels]]

Latest revision as of 16:57, 8 May 2026

System Specifications
FACP: Edwards EST2
FACP Location: Main Entrance Vestibule
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: Yes, Self-Sync
Date of last known Upgrade: N/A
Year Opened: 1999

Best Western is a chain of hotels headquartered in Phoenix, Arizona. This particular hotel is located at 3630 Macleod Trail South, in Calgary, Alberta, Canada. The hotel was built in 1999, and the fire alarm system is original.

System Specifications

FACP

The building is protected by an Edwards EST2 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Edwards' Signature addressable protocol, and the system coding is temporal.

Notification Appliances

All common areas have Edwards "Integrity" 757-5A-T horn/strobes (red, wall-mount, 15cd).
All guest rooms have Edwards 202-5A-T remote strobes (red, wall-mount, 15cd) paired with Edwards 683-1CR silenceable mini-horns (red).

Initiating Devices

Pull Stations

All pull stations are EST SIGA-270 addressable single-action pull stations.

Automatic Detection Devices

There are EST SIGA-PS addressable photoelectric smoke detectors throughout all corridors, and at the top of each stairwell, mounted on EST SIGA-SB bases.

Modules

There are EST SIGA-WTM addressable monitor modules supervising the sprinkler system's tamper and flow switches.
There are EST SIGA-CR addressable relay modules serving various purposes.
All signalling circuits utilize EST SIGA-MCC2 signal control modules.

EOLs

There are Edwards EOL-P1 end of line resistor plates on all sprinkler and signal circuits.