Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

Days Inn by Wyndham Edmonton Airport: Difference between revisions

From FireAlarmPedia
 
Line 17: Line 17:
All pull stations are Mircom MS-401AD addressable single-action pull stations.
All pull stations are Mircom MS-401AD addressable single-action pull stations.
====Automatic Detection Devices====
====Automatic Detection Devices====
There are Mircom MIX-2251BA addressable photoelectric smoke detectors throughout all common areas, mounted on System Sensor B710LPA bases.
There are Mircom MIX-2251BA addressable photoelectric smoke detectors throughout all common areas, mounted on System Sensor B210LPA bases.


==== Modules ====
==== Modules ====

Latest revision as of 12:30, 24 October 2024

System Specifications
FACP: Mircom FX-2000
FACP Location: Unknown
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Temporal
Strobes Synchronized: No
Date of last known Upgrade: N/A
Year Opened: 2008

Days Inn is a chain of budget hotels owned by Wyndham Group. They are headquartered in Parsippany, New Jersey. This particular hotel is located at 8116 Sparrow Crescent, in Leduc, Alberta, Canada, and primarily serves the Edmonton International Airport. The hotel opened in 2008, and was renovated in 2017. The fire alarm system survived the renovations and is original.

System Specifications[edit | edit source]

FACP[edit | edit source]

The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel location is unknown. The system runs Mircom’s CLIP addressable protocol, and the system coding is temporal.

Notification Appliances[edit | edit source]

All common area notification appliances are Mircom “Select-A-Horn/Strobe” FHS-240R horn/strobes (red, wall-mount, set to broadband/15cd). The guest rooms have Mircom FHS-240W horn/strobes (white, wall-mount, set to broadband/15cd).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are Mircom MS-401AD addressable single-action pull stations.

Automatic Detection Devices[edit | edit source]

There are Mircom MIX-2251BA addressable photoelectric smoke detectors throughout all common areas, mounted on System Sensor B210LPA bases.

Modules[edit | edit source]

There are Mircom MIX-M500MA addressable monitor modules supervising the sprinkler system's tamper and flow switches.

There are Mircom MIX-M500RA addressable relay modules serving various purposes.

There are System Sensor M500XA isolator modules on the SLC.

EOLs[edit | edit source]

There are Mircom MP-300 end of line resistor plates on all sprinkler and signal circuits.